David. A. Horsley

David. A. Horsley

Auto-generated profile, based on publicly available information

David. A. Horsley

University of California, Davis, USA

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YLY. Lu
Y. Lu
HTH. Tang
H. Tang
SFS. Fung
S. Fung
QWQ. Wang
Q. Wang
JTJ. M. Tsai
J. M. Tsai
DHD. A. Horsley
D. A. Horsley
This paper presents an ultrasonic fingerprint sensor based on a 24 × 8 array of 22 MHz piezoelectric micromachined ultrasonic transducers (PMUTs) with 100 μm pitch, fully integrated with 180 nm complementary metal oxide semiconductor (CMOS) circuitry through eutectic wafer bonding. Each PMUT is directly bonded to a dedicated CMOS receive amplifier, minimizing electrical parasitics and eliminating the need for through-silicon vias. The array frequency response and vibration mode-shape were characterized using laser Doppler vibrometry and verified via finite element method simulation. The array's acoustic output was measured using a hydrophone to be ∼14 kPa with a 28 V input, in reasonable agreement with predication from analytical calculation. Pulse-echo imaging of a 1D steel grating is demonstrated using electronic scanning of a 20 × 8 sub-array, resulting in 300 mV maximum received amplitude and 5:1 contrast ratio. Because the small size of this array limits the maximum image size, mechanical scanning was used to image a 2D polydimethylsiloxane fingerprint phantom (10 mm × 8 mm) at a 1.2 mm distance from the array.

12 March 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SNSarah H. Nitzan
Sarah H. Nitzan
Valentina ZegaValentina Zega
Valentina Zega
MLMo Li
Mo Li
CAChae H. Ahn
Chae H. Ahn
Alberto CoriglianoAlberto Corigliano
Alberto Corigliano
DHDavid A. Horsley
David A. Horsley
Parametric amplification, resulting from intentionally varying a parameter in a resonator at twice its resonant frequency, has been successfully employed to increase the sensitivity of many micro- and nano-scale sensors. Here, we introduce the concept of self-induced parametric amplification, which arises naturally from nonlinear elastic coupling between the degenerate vibration modes in a micromechanical disk-resonator and is not externally applied. The device functions as a gyroscope wherein angular rotation is detected from Coriolis coupling of elastic vibration energy from a driven vibration mode into a second degenerate sensing mode. While nonlinear elasticity in silicon resonators is extremely weak, in this high quality-factor device, ppm-level nonlinear elastic effects result in an order-of-magnitude increase in the observed sensitivity to Coriolis force relative to linear theory. Perfect degeneracy of the primary and secondary vibration modes is achieved through electrostatic frequency tuning, which also enables the phase and frequency of the parametric coupling to be varied and we show that the resulting phase and frequency dependence of the amplification follow the theory of parametric resonance. We expect that this phenomenon will be useful for both fundamental studies of dynamic systems with low dissipation and for increasing signal-to-noise ratio in practical applications such as gyroscopes.

15 December 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CAC. H. Ahn
C. H. Ahn
SNS. Nitzan
S. Nitzan
ENE. J. Ng
E. J. Ng
VHV. A. Hong
V. A. Hong
YYY. Yang
Y. Yang
TKT. W. Kenny
T. W. Kenny
In this paper, we explore the effects of electrostatic parametric amplification on a high quality factor (Q > 100 000) encapsulated disk resonator gyroscope (DRG), fabricated in 〈100〉 silicon. The DRG was operated in the n = 2 degenerate wineglass mode at 235 kHz, and electrostatically tuned so that the frequency split between the two degenerate modes was less than 100 mHz. A parametric pump at twice the resonant frequency is applied to the sense axis of the DRG, resulting in a maximum scale factor of 156.6 μV/(°/s), an 8.8× improvement over the non-amplified performance. When operated with a parametric gain of 5.4, a minimum angle random walk of 0.034°/√h and bias instability of 1.15°/h are achieved, representing an improvement by a factor of 4.3× and 1.5×, respectively.

6 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AGAndré Guedes
André Guedes
RMRita Macedo
Rita Macedo
GJGerardo Jaramillo
Gerardo Jaramillo
Susana Cardoso De FreitasSusana Cardoso De Freitas
Susana Cardoso De Freitas
PFPaulo Freitas*
Paulo Freitas*
DHDavid A. Horsley
David A. Horsley
Advances in the magnetic sensing technology have been driven by the increasing demand for the capability of measuring ultrasensitive magnetic fields. Among other emerging applications, the detection of magnetic fields in the picotesla range is crucial for biomedical applications. In this work Picosense reports a millimeter-scale, low-power hybrid magnetoresistive-piezoelectric magnetometer with subnanotesla sensitivity at low frequency. Through an innovative noise-cancelation mechanism, the 1/f noise in the MR sensors is surpassed by the mechanical modulation of the external magnetic fields in the high frequency regime. A modulation efficiency of 13% was obtained enabling a final device’s sensitivity of ~950 pT/Hz1/2 at 1 Hz. This hybrid device proved to be capable of measuring biomagnetic signals generated in the heart in an unshielded environment. This result paves the way for the development of a portable, contactless, low-cost and low-power magnetocardiography device.

10 October 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
MDMartial Defoort
Martial Defoort
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
DHD. A. Horsley
D. A. Horsley
Resonators used in frequency-reference oscillators must maintain a stable frequency output even when subjected to temperature variations. The traditional solution is to construct the resonator from a material with a low temperature coefficient, such as AT-cut quartz, which can achieve absolute frequency stability on the order of ±25 ppm over commercial temperature ranges. In comparison, Si microresonators suffer from the disadvantage that silicon's temperature coefficient of frequency (TCF) is approximately two orders of magnitude greater than that of AT-cut quartz. In this paper, we present an in situ passive temperature compensation scheme for Si microresonators based on nonlinear amplitude-frequency coupling which reduces the TCF to a level comparable with that of an AT-quartz resonator. The implementation of this passive technique is generic to a variety of Si microresonators and can be applied to a number of frequency control and timing applications.

11 May 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YLY. Lu
Y. Lu
HTH. Tang
H. Tang
QWQ. Wang
Q. Wang
SFS. Fung
S. Fung
JTJ. M. Tsai
J. M. Tsai
DHD. A. Horsley
D. A. Horsley
This paper presents an 8 × 24 element, 100 μm-pitch, 20 MHz ultrasound imager based on a piezoelectric micromachined ultrasonic transducer (PMUT) array having integrated acoustic waveguides. The 70 μm diameter, 220 μm long waveguides function both to direct acoustic waves and to confine acoustic energy, and also to provide mechanical protection for the PMUT array used for surface-imaging applications such as an ultrasonic fingerprint sensor. The imager consists of a PMUT array bonded with a CMOS ASIC using wafer-level conductive eutectic bonding. This construction allows each PMUT in the array to have a dedicated front-end receive amplifier, which together with on-chip analog multiplexing enables individual pixel read-out with high signal-to-noise ratio through minimized parasitic capacitance between the PMUT and the front-end amplifier. Finite element method simulations demonstrate that the waveguides preserve the pressure amplitude of acoustic pulses over distances of 600 μm. Moreover, the waveguide design demonstrated here enables pixel-by-pixel readout of the ultrasound image due to improved directivity of the PMUT by directing acoustic waves and creating a pressure field with greater spatial uniformity at the end of the waveguide. Pulse-echo imaging experiments conducted using a one-dimensional steel grating demonstrate the array's ability to form a two-dimensional image of a target.