Purpose: To develop a framework that jointly estimates rigid motion and polarizing magnetic field (B0) perturbations () for brain MRI using a single navigator of a few milliseconds in duration, and to additionally allow for navigator acquisition at arbitrary timings within any type of sequence to obtain high‐temporal resolution estimates.Theory and Methods: Methods exist that match navigator data to a low‐resolution single‐contrast image (scout) to estimate either motion or . In this work, called QUEEN (QUantitatively Enhanced parameter Estimation from Navigators), we propose combined motion and estimation from a fast, tailored trajectory with arbitrary‐contrast navigator data. To this end, the concept of a quantitative scout (Q‐Scout) acquisition is proposed from which contrast‐matched scout data is predicted for each navigator. Finally, navigator trajectories, contrast‐matched scout, and are integrated into a motion‐informed parallel‐imaging framework.Results: Simulations and in vivo experiments show the need to model to obtain accurate motion parameters estimated in the presence of strong . Simulations confirm that tailored navigator trajectories are needed to robustly estimate both motion and . Furthermore, experiments show that a contrast‐matched scout is needed for parameter estimation from multicontrast navigator data. A retrospective, in vivo reconstruction experiment shows improved image quality when using the proposed Q‐Scout and QUEEN estimation.Conclusions: We developed a framework to jointly estimate rigid motion parameters and from navigators. Combing a contrast‐matched scout with the proposed trajectory allows for navigator deployment in almost any sequence and/or timing, which allows for higher temporal‐resolution motion and estimates.
Purpose Dynamic angiography using arterial spin labeling (ASL) can provide detailed hemodynamic information. However, the long time-resolved readouts require small flip angles to preserve ASL signal for later timepoints, limiting SNR. By using time-encoded ASL to generate temporal information, the readout can be shortened. Here, the SNR improvements from using larger flip angles, made possible by the shorter readout, are quantitatively investigated. Methods The SNR of a conventional protocol with nine Look-Locker readouts and a 4 x$$ \times $$ 3 time-encoded protocol with three Look-Locker readouts (giving nine matched timepoints) were compared using simulations and in vivo data. Both protocols were compared using readouts with constant flip angles (CFAs) and variable flip angles (VFAs), where the VFA scheme was designed to produce a consistent ASL signal across readouts. Optimization of the background suppression to minimize physiological noise across readouts was also explored. Results The time-encoded protocol increased in vivo SNR by 103% and 96% when using CFAs or VFAs, respectively. Use of VFAs improved SNR compared with CFAs by 25% and 21% for the conventional and time-encoded protocols, respectively. The VFA scheme also removed signal discontinuities in the time-encoded data. Preliminary data suggest that optimizing the background suppression could improve in vivo SNR by a further 16%. Conclusions Time encoding can be used to generate additional temporal information in ASL angiography. This enables the use of larger flip angles, which can double the SNR compared with a non-time-encoded protocol. The shortened time-encoded readout can also lead to improved background suppression, reducing physiological noise and further improving SNR.
19 September 2019 in Magnetic Resonance in Medicine
Purpose: To demonstrate that vessel selectivity in dynamic arterial spin labeling angiography can be achieved without any scan‐time penalty or noticeable loss of image quality compared with conventional arterial spin labeling angiography.Methods: Simulations on a numerical phantom were used to assess whether the increased sparsity of vessel‐encoded angiograms compared with non‐vessel‐encoded angiograms alone can improve reconstruction results in a compressed‐sensing framework. Further simulations were performed to study whether the difference in relative sparsity between nonselective and vessel‐selective dynamic angiograms was sufficient to achieve similar image quality at matched scan times in the presence of noise. Finally, data were acquired from 5 healthy volunteers to validate the technique in vivo. All data, both simulated and in vivo, were sampled in 2D using a golden‐angle radial trajectory and reconstructed by enforcing image domain sparsity and temporal smoothness on the angiograms in a parallel imaging and compressed‐sensing framework.Results: Relative sparsity was established as a primary factor governing the reconstruction fidelity. Using the proposed reconstruction scheme, differences between vessel‐selective and nonselective angiography were negligible compared with the dominant factor of total scan time in both simulations and in vivo experiments at acceleration factors up to R = 34. The reconstruction quality was not heavily dependent on hand‐tuning the parameters of the reconstruction.Conclusion: The increase in relative sparsity of vessel‐selective angiograms compared with nonselective angiograms can be leveraged to achieve higher acceleration without loss of image quality, resulting in the acquisition of vessel‐selective information at no scan‐time cost.
1 February 2025 in Magnetic Resonance Materials in Physics, Biology and Medicine
Object: Spatio-temporal MRI methods offer rapid whole-brain multi-parametric mapping, yet they are often hindered by prolonged reconstruction times or prohibitively burdensome hardware requirements. The aim of this project is to reduce reconstruction time using deep learning. Materials and methods: This study focuses on accelerating the reconstruction of volumetric multi-axis spiral projection MRF, aiming for whole-brain T1 and T2 mapping, while ensuring a streamlined approach compatible with clinical requirements. To optimize reconstruction time, the traditional method is first revamped with a memory-efficient GPU implementation. Deep Learning Initialized Compressed Sensing (Deli-CS) is then introduced, which initiates iterative reconstruction with a DL-generated seed point, reducing the number of iterations needed for convergence. Results: The full reconstruction process for volumetric multi-axis spiral projection MRF is completed in just 20 min compared to over 2 h for the previously published implementation. Comparative analysis demonstrates Deli-CS’s efficiency in expediting iterative reconstruction while maintaining high-quality results. Discussion: By offering a rapid warm start to the iterative reconstruction algorithm, this method substantially reduces processing time while preserving reconstruction quality. Its successful implementation paves the way for advanced spatio-temporal MRI techniques, addressing the challenge of extensive reconstruction times and ensuring efficient, high-quality imaging in a streamlined manner.