Mark Chiew

Dr. Mark Chiew

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2023 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Open access
CMCharles Millard
Charles Millard
MCMark Chiew
Mark Chiew
In recent years, there has been attention on leveraging the statistical modeling capabilities of neural networks for reconstructing sub-sampled Magnetic Resonance Imaging (MRI) data. Most proposed methods assume the existence of a representative fully-sampled dataset and use fully-supervised training. However, for many applications, fully sampled training data is not available, and may be highly impractical to acquire. The development and understanding of self-supervised methods, which use only sub-sampled data for training, are therefore highly desirable. This work extends the Noisier2Noise framework, which was originally constructed for self-supervised denoising tasks, to variable density sub-sampled MRI data. We use the Noisier2Noise framework to analytically explain the performance of Self-Supervised Learning via Data Undersampling (SSDU), a recently proposed method that performs well in practice but until now lacked theoretical justification. Further, we propose two modifications of SSDU that arise as a consequence of the theoretical developments. Firstly, we propose partitioning the sampling set so that the subsets have the same type of distribution as the original sampling mask. Secondly, we propose a loss weighting that compensates for the sampling and partitioning densities. On the fastMRI dataset we show that these changes significantly improve SSDU's image restoration quality and robustness to the partitioning parameters.

1 November 2020 in NeuroImage
Verified
Journal Article
Open access
CWChaoyue Wang
Chaoyue Wang
SFSean Foxley
Sean Foxley
OAOlaf Ansorge
Olaf Ansorge
SBSarah Bangerter-Christensen
Sarah Bangerter-Christensen
MCMark Chiew
Mark Chiew
BTBenjamin C. Tendler
Benjamin C. Tendler
Susceptibility weighted magnetic resonance imaging (MRI) is sensitive to the local concentration of iron and myelin. Here, we describe a robust image processing pipeline for quantitative susceptibility mapping (QSM) and R2* mapping of fixed post-mortem, whole-brain data. Using this pipeline, we compare the resulting quantitative maps in brains from patients with amyotrophic lateral sclerosis (ALS) and controls, with validation against iron and myelin histology.

25 September 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
XSXin Shen
Xin Shen
AÖAli Caglar Özen
Ali Caglar Özen
ASAntonia Sunjar
Antonia Sunjar
SISerhat Ilbey
Serhat Ilbey
SSStephen Sawiak
Stephen Sawiak
Uzay EmirUzay Emir
Uzay Emir
Purpose: This study aimed to develop a new 3D dual‐echo rosette k‐space trajectory, specifically designed for UTE MRI applications. The imaging of the ultra‐short transverse relaxation time (uT2) of brain was acquired to test the performance of the proposed UTE sequence.Theory and Methods: The rosette trajectory was developed based on rotations of a “petal‐like” pattern in the kx–ky plane, with oscillated extensions in the kz‐direction for 3D coverage. Five healthy volunteers underwent 10 dual‐echo 3D rosette UTE scans with various TEs. Dual‐exponential complex model fitting was performed on the magnitude data to separate uT2 signals, with the output of uT2 fraction, uT2 value, and long‐T2 value.Results: The 3D rosette dual‐echo UTE sequence showed better performance than a 3D radial UTE acquisition. More significant signal intensity decay in white matter than gray matter was observed along with the TEs. The white matter regions had higher uT2 fraction values than gray matter (10.9% ± 1.9% vs. 5.7% ± 2.4%). The uT2 value was approximately 0.10 ms in white matter .Conclusion: The higher uT2 fraction value in white matter compared to gray matter demonstrated the ability of the proposed sequence to capture rapidly decaying signals.

8 September 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
NGNadine N. Graedel
Nadine N. Graedel
JMJennifer A. McNab
Jennifer A. McNab
MCMark Chiew
Mark Chiew
KMKarla L. Miller
Karla L. Miller
Subject motion is a major source of image degradation for functional MRI (fMRI), especially when using multishot sequences like three-dimensional (3D EPI). We present a hybrid radial-Cartesian 3D EPI trajectory enabling motion correction in k-space for functional MRI. The EPI “blades” of the 3D hybrid radial-Cartesian EPI sequence, called TURBINE, are rotated about the phase-encoding axis to fill out a cylinder in 3D k-space. Angular blades are acquired over time using a golden-angle rotation increment, allowing reconstruction at flexible temporal resolution. The self-navigating properties of the sequence are used to determine motion parameters from a high temporal-resolution navigator time series. The motion is corrected in k-space as part of the image reconstruction, and evaluated for experiments with both cued and natural motion. We demonstrate that the motion correction works robustly and that we can achieve substantial artifact reduction as well as improvement in temporal signal-to-noise ratio and fMRI activation in the presence of both severe and subtle motion. We show the potential for hybrid radial-Cartesian 3D EPI to substantially reduce artifacts for application in fMRI, especially for subject groups with significant head motion. The motion correction approach does not prolong the scan, and no extra hardware is required. Magn Reson Med 78:527–540, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

17 May 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ASAdam Steel
Adam Steel
MCMark Chiew
Mark Chiew
PJPeter Jezzard
Peter Jezzard
NVNatalie L. Voets
Natalie L. Voets
PPPuneet Plaha
Puneet Plaha
Uzay EmirUzay Emir
Uzay Emir
Magnetic resonance spectroscopic imaging (MRSI) is a promising technique in both experimental and clinical settings. However, to date, MRSI has been hampered by prohibitively long acquisition times and artifacts caused by subject motion and hardware-related frequency drift. In the present study, we demonstrate that density weighted concentric ring trajectory (DW-CRT) k-space sampling in combination with semi-LASER excitation and metabolite-cycling enables high-resolution MRSI data to be rapidly acquired at 3 Tesla. Single-slice full-intensity MRSI data (short echo time (TE) semi-LASER TE = 32 ms) were acquired from 6 healthy volunteers with an in-plane resolution of 5 × 5 mm in 13 min 30 sec using this approach. Using LCModel analysis, we found that the acquired spectra allowed for the mapping of total N-acetylaspartate (median Cramer-Rao Lower Bound [CRLB] = 3%), glutamate+glutamine (8%), and glutathione (13%). In addition, we demonstrate potential clinical utility of this technique by optimizing the TE to detect 2-hydroxyglutarate (long TE semi-LASER, TE = 110 ms), to produce relevant high-resolution metabolite maps of grade III IDH-mutant oligodendroglioma in a single patient. This study demonstrates the potential utility of MRSI in the clinical setting at 3 Tesla.

21 September 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
WCWilliam Thomas Clarke
William Thomas Clarke
MCMark Chiew
Mark Chiew
Purpose: Low‐rank denoising of MRSI data results in an apparent increase in spectral SNR. However, it is not clear if this translates to a lower uncertainty in metabolite concentrations after spectroscopic fitting. Estimation of the true uncertainty after denoising is desirable for downstream analysis in spectroscopy. In this work, the uncertainty reduction from low‐rank denoising methods based on spatiotemporal separability and linear predictability in MRSI are assessed. A new method for estimating metabolite concentration uncertainty after denoising is proposed. Automatic rank threshold selection methods are also assessed in simulated low SNR regimes.Methods: Assessment of denoising methods is conducted using Monte Carlo simulation of proton MRSI data and by reproducibility of repeated in vivo acquisitions in 5 subjects.Results: In simulated and in vivo data, spatiotemporal based denoising is shown to reduce the concentration uncertainty, but linear prediction denoising increases uncertainty. Uncertainty estimates provided by fitting algorithms after denoising consistently underestimate actual metabolite uncertainty. However, the proposed uncertainty estimation, based on an analytical expression for entry‐wise variance after denoising, is more accurate. It is also shown automated rank threshold selection using Marchenko‐Pastur distribution can bias the data in low SNR conditions. An alternative soft‐thresholding function is proposed.Conclusion: Low‐rank denoising methods based on spatiotemporal separability do reduce uncertainty in MRS(I) data. However, thorough assessment is needed as assessment by SNR measured from residual baseline noise is insufficient given the presence of non‐uniform variance. It is also important to select the right rank thresholding method in low SNR cases.