Yuqing Hu

Yuqing Hu

Auto-generated profile, based on publicly available information

Yuqing Hu

Zhejiang Key Laboratory of Extremely-Weak Magnetic Field Space and Application Technology, Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KTKangqi Tian
Kangqi Tian
Xu ZhangXu Zhang
Xu Zhang
Min XiangMin Xiang
Min Xiang
Jianzhi YangJianzhi Yang
Jianzhi Yang
AZAo Zhang
Ao Zhang
GLGang Liu
Gang Liu
Ischemic chronic heart failure (ICHF) that is accompanied by bundle-branch block (BBB) represents a complex cardiac electrophysiological abnormality that has a significant impact on cardiac function. Under complex pathological cardiac conditions, signal changes are often insufficiently detected. Owing to the fixed and limited number of electrode placements of the electrocardiogram (ECG) subtle, abnormal, cardiac electrophysiological signals are difficult to capture comprehensively. In contrast, magnetocardiographs (MCGs) measured by spin-exchange relaxation-free (SERF) magnetometers, with their higher sensitivity and spatial resolution, represent cardiac electrical activity more accurately. However, owing to the longer electrical-conduction pathways of the cardiac deep structure and the superimposition of abnormal signals from the BBB-accompanied ICHF, these abnormal signals are weak and capture by SERF magnetometers is difficult; precise identification of the MCG features is thus more challenging. To address these technical limitations and enhance the detection of cardiac electrophysiological abnormalities, a more precise solution is required. In this paper, a comprehensive cardiac electrophysiological-conduction model and simulation method are proposed. Conduction pathways are mathematically modeled, and their contributions to the magnetic field are calculated. Detailed images of cardiac electrical activity are obtained through interpolation of MCGs. More accurate MCG data are generated by solving the comprehensive myocardial current I’total. Simulated MCGs provide new insights for the MCG-technology optimization and highlight the value of cardiac electrophysiological conduction models in MCG measurements, thereby significantly improving the early detection and diagnosis of BBB.

11 December 2024 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
KTKangqi Tian
Kangqi Tian
Xu ZhangXu Zhang
Xu Zhang
MSminxia shi
minxia shi
Jianzhi YangJianzhi Yang
Jianzhi Yang
ZSZiyang Shi
Ziyang Shi
GLGang Liu
Gang Liu
The MINI-magnetically shielded cabin (MINI-MSC) offers a near-zero magnetic environment for optically pumped atomic magnetometers (OPMs) to measure the magnetocardiography (MCG) and magnetoencephalography (MEG). However, the MINI-MSC’s confined interior and restricted uniform area make it challenging to capture high-quality bodily signals. Once the external interference surpasses the passive magnetic shielding capacity of the MINI-MSC, the volume and the homogeneity of the uniform region are reduced significantly, leading to the poor quality of the signal collected by OPMs. Therefore, an uniform active magnetic compensation system (UAMCS) composed of bi-planar coils (BCs) is introduced to suppress interference for enlarging the uniform region. The performance of the UAMCS depends on the BCs, but under finite-size ferromagnetic boundaries, approximate magnetic field values that deviate from reality are usually provided by the image method with the inaccurate calculation. To overcome these limitations, an analytical expression of the absorption current is derived to accurately characterize the coupling effect, thereby maintaining the high uniformity performance effectively. A forward analytical model is proposed to characterize magnetic fields, and the equivalent current could be analytically determined, which are put into the target field method (TFM) to express the superimposed the magnetic field. The inhomogeneity errors of BCs using the forward analytical model are 0.39 times of the image method. After the magnetic compensation, the signal-to-noise ratio at 0.1 Hz, 1 Hz and 10 Hz were improved by 39.5 dB, 34.3 dB, and 6.7 dB, respectively, verifying the magnetic noise can be well compensated in the whole target region. Note to Practitioners —The challenge of ensuring high signal quality in MINI-MSC for OPMs is critical in biomedical imaging applications. An forward analytical method is introduced to character the absorbed magnetic field of shielding layers, and an advanced UAMCS utilizing BCs is used for the precise magnetic field compensation to significantly enhance the signal-to-noise ratio. This approach addresses the limitations of traditional image methods, offering improved accuracy in magnetic compensation and enhance the reliability of MEG and MCG tests.

21 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KTKangqi Tian
Kangqi Tian
Xu ZhangXu Zhang
Xu Zhang
Jianzhi YangJianzhi Yang
Jianzhi Yang
YHYuqing Hu
Yuqing Hu
AZAo Zhang
Ao Zhang
GLGang Liu
Gang Liu
In the electrophysiological study of ischemic chronic heart failure (I-CHF) patients, cardiac electrical activity is captured using body surface electrodes in traditional electrocardiography (ECG). However, due to its limited spatial resolution, surface potential changes are reflected by ECG, and deep cardiac electrophysiological signals are struggled to be accurately detected, especially under complex pathological conditions. To address this limitation, a forward problem analytical model based on a three-dimensional cardiac-torso model for magnetocardiography (MCG) is proposed. An individualized ventricular-torso dual-domain model is constructed, and an improved diffusion equation is employed to accurately simulate the potential distribution between the endocardium and epicardium in I-CHF patients. The dynamic characteristics of the three-dimensional equivalent current density within cardiac tissue are analyzed. The simulated three-dimensional potential distribution is converted into a body surface magnetic field distribution and compared with MCGs obtained using a spin-exchange relaxation-free (SERF) magnetometer array. The proposed electromagnetic conversion analytical model demonstrates improvements in accuracy. At the peak moments of the R-wave and T-wave, significant differences in SSIM values are observed between normal individuals and ICHF patients. SSIM values for normal individuals are higher (R-wave 0.9066, T-wave 0.8537) compared to I-CHF patients (R-wave 0.8135, T-wave 0.8231). The simulated and measured data for the healthy group are consistent, while for the I-CHF group, the simulated gain and offset increase from 0.98 and 1.98 to 1.06 and 2.25, and the measured gain and offset decrease from 0.81 and 3.02 to 0.78 and 2.87. These results highlight the model’s ability to differentiate between normal and I-CHF conditions, providing a promising tool for early diagnosis of diseases.

26 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KTKangqi Tian
Kangqi Tian
Xu ZhangXu Zhang
Xu Zhang
Jianzhi YangJianzhi Yang
Jianzhi Yang
ZSZiyang Shi
Ziyang Shi
YHYuqing Hu
Yuqing Hu
GLGang Liu
Gang Liu
The magnetically shielded booth (MSB), noted for its compactness and high-cost performance, offers a near-zero magnetic environment for magnetoencephalography (MEG) and magnetocardiography (MCG). However, the limited internal space inside the MSB, with large gradient distributions, is not conducive to enhancing the performance of optically pumped atomic magnetometers (OPMs). Meanwhile, the actual MSB is a complex structure with ventilation and wave-guide holes such that the shielding layer is not equivalent to an ideal plane. The traditional image method (IM) for designing coils aiming to suppress the ferromagnetic boundary coupling, is limited to eliminating the partial gradient field, which limits the accuracy of the active magnetic compensation system and is unable to achieve high signal-to-noise ratio (SNR). To mitigate these issues, the biplanar gradient coil (BGC) has been introduced to eliminate the larger gradients. In this study, dBx/dz and dBx/dz coils were designed using the optimized multiple image method (O-MIM). The thickness of the magnetic shielding layer was considered to reduce the field gradient, which has the most influence on OPMs’ sensitivity. Experiments showed that the maximum gradient inhomogeneity error in the target region is less than 1.16%, which is consistent with simulation predictions. When active magnetic compensation system-BGCs (AMCS-BGCs) were operating, the maximum residual gradient ΔG of the dBx/dz and dBx/dz coils designed by the O-MIM and IM, were 0.8 nT/m and 12.1 nT/m, 0.7 nT/m and 16.2 nT/m, respectively, whereby a more uniform gradient and larger region of gradient field were obtained during MCG and MEG tests.