Dominic Humphrey

Dominic Humphrey

Auto-generated profile, based on publicly available information

Dominic Humphrey

UCL Energy Institute, Bartlett Faculty of the Built Environment, University College London, London

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2020 in Buildings and Cities
Verified
Journal Article
Open access
PDF file
PSPhilip Steadman
Philip Steadman
SEStephen Evans
Stephen Evans
RLRob Liddiard
Rob Liddiard
DGDaniel Godoy-Shimizu
Daniel Godoy-Shimizu
PRPaul Ruyssevelt
Paul Ruyssevelt
DHDominic Humphrey
Dominic Humphrey
A brief history is provided of models of energy use in the UK building stock, with the focus on the non-domestic sector. This history leads to an account of the development, since 2009, of the 3DStock method for modelling complete building stocks, both domestic and non-domestic. The paper explains how 3DStock models are built and the data sources used. Special emphasis is placed on the relationship of premises (the floorspace occupied by organisations) to buildings. Energy use may be metered at the level of premises, buildings or groups of buildings. Representing the patterns in which premises relate to buildings is therefore crucial to the modelling process, and in particular to the precise measurement of energy intensities. Applications of 3DStock models in building science and policy tools are reviewed, including the London Building Stock Model (LBSM), delivered to the Greater London Authority (GLA) in 2020. This 'digital twin' can be used for the monitoring, simulation and analysis of the building stock. Implications for research and policy are discussed, particularly for energy epidemiology, density, high-rise buildings, retrofit potential, energy-use intensity and benchmarking. Data are in place to extend 3DStock modelling to the whole of England and Wales. Policy and practice relevance The models can be used to assess energy demand in large numbers of buildings in relation to a range of variables, including built form, age, construction and activities. Poorly performing buildings can be identified, and the potential for retrofit-including renewable technology installations-evaluated using the same variables plus information contained in Energy Performance Certificates (EPCs). Policies for addressing fuel poverty can be evaluated by making links to confidential socioeconomic data on occupants. In conjunction with a dynamic building energy-simulation tool, scenarios can be investigated for retrofit, the potential for renewables and issues in demand-side management. Additional uses are in the precise measurements of density and of the three-dimensional character of the urban fabric. There could be applications in public health, the modelling of indoor and outdoor air pollution, and the tracking of material flows. 3DStock models might also be integrated with digital twins of infrastructure systems and networks.

4 January 2021 in Buildings and Cities
Verified
Journal Article
Open access
PDF file
RLRob Liddiard
Rob Liddiard
DGDaniel Godoy-Shimizu
Daniel Godoy-Shimizu
PRPaul Ruyssevelt
Paul Ruyssevelt
PSPhilip Steadman
Philip Steadman
SEStephen Evans
Stephen Evans
RARayan Azhari
Rayan Azhari

2 January 2023 in Buildings and Cities
Verified
Journal Article
Open access
PDF file
SEStephen Evans
Stephen Evans
DGDaniel Godoy-Shimizu
Daniel Godoy-Shimizu
PSPhilip Steadman
Philip Steadman
SAShyam Amrith
Shyam Amrith
DHDominic Humphrey
Dominic Humphrey
PRPaul Ruyssevelt
Paul Ruyssevelt
This paper describes the development of a detailed plan to get the social housing stock of the Borough of Islington in London, UK, to net zero carbon emissions. This stock is very diverse in form, age and construction, and includes houses, flats and maisonettes. A total of 4500 buildings containing some 33,300 dwellings were modelled using the 3DStock method. Six packages of measures combining fabric improvements, heat pumps and photovoltaic installations were evaluated for each dwelling individually, in terms of costs, the impacts on gas and electricity use, and predicted cuts in carbon emissions. The rollout of measures between 2020 and 2030 was modelled with a specially developed scenario tool, allowing the user to set different criteria and priorities. Fabric measures on their own were shown to achieve only a 13% cut in gas use on average. Heat pumps are the key to displacing gas use. With all measures combined and taking account of the predicted decarbonisation of the electricity supply, it is only possible to achieve an overall 70% cut in emissions by 2030. Policy relevance The development of a detailed practical plan of action is described: an applied case study with the close engagement of the local authority—not a theoretical desk exercise. Each dwelling in Islington’s housing stock was examined and measured separately. The modelling did not rely on ‘archetypes’ as in many such studies. Realistic retrofit options were analysed in each case, using current cost data from practitioners. The same approach could be applied directly to other London boroughs, and for local authorities outside the capital, although different costs and other local factors would apply. For readers outside the UK, the methodology and tools could serve as exemplars. The findings about the respective contributions of heat pumps, solar photovoltaics and fabric measures, and the effects of different priorities in the rollout of retrofits, have relevance for policymaking more generally at local and national levels.

27 May 2024 in Buildings and Cities
Verified
Journal Article
Open access
PDF file
Frances HollickFrances Hollick
Frances Hollick
DHDominic Humphrey
Dominic Humphrey
TOTadj Oreszczyn
Tadj Oreszczyn
Clifford ElwellClifford Elwell
Clifford Elwell
GHGesche Huebner
Gesche Huebner
The lockdowns introduced to prevent the spread of COVID-19 had huge impacts, as people were largely confined to their homes. It could be expected that residential energy use would increase while non-residential decreased, however the picture is not so clear. Here three complementary datasets on different scales are used to explore changes in building energy use during two UK lockdowns: the complete building stock of Great Britain, a sample of approximately 1000 residential buildings, and one of about 24,000 residential boilers. Energy-signature analysis was used for the building data to estimate the changes in demand for space heating and other uses, with the boiler data able to separate space and water heating and explore changes in these. In the 2020 lockdown residential energy consumption for water heating and appliances increased, with decreased use for space heating, resulting in a reduction in total energy use during the heating season. In the 2021 lockdown total energy consumption changed little, however a decrease in the use of gas space heating was observed. The residential changes counteracted non-domestic changes, resulting in little difference in national energy consumption. These results highlight how longitudinal datasets enabled by Internet of Things-enabled devices can be crucial as an evidence base for research. Policy relevance The impacts on national energy consumption of increased time spent at home provide an important context for the pursuit of net zero targets, particularly with the rise in flexible working seen since 2020. That little change was seen overall could be due to the energy use in non-domestic buildings not decreasing proportionately to their decrease in use during national lockdowns, and thus seeking to lower non-domestic energy use to account for lower utilisation of spaces could deliver carbon and cost savings. This could be achieved through measures such as automated switch-off services, demand controlled heating and ventilation, and reduction in space. The finding that drastic changes were not made to home heating behaviours could have implications for future demand-side response schemes, indicating that perhaps occupants are happy to adapt to cooler conditions by achieving comfort in other ways.

12 June 2026 in Buildings and Cities
Verified
Journal Article
Open access
PDF file
SEStephen Evans
Stephen Evans
PSPhilip Steadman
Philip Steadman
ANAndré Neto-Bradley
André Neto-Bradley
DHDominic Humphrey
Dominic Humphrey
RLRob Liddiard
Rob Liddiard
GSGareth Simons
Gareth Simons
The National Buildings Database (NBD) has been delivered to the UK Department for Energy Security and Net Zero (DESNZ). This covers the complete population of 2.2 million non-domestic premises and 30 million dwellings in Great Britain (but not Northern Ireland). Each is modelled in detail, in three dimensions, using the 3DStock method. Actual annual meter data are attached. This paper outlines some of the myths about the building stock—its composition, representation, age, total floor area, activity classification and energy use—that the authors have encountered in their 20 years of working on stock models, consumption of energy and strategies for decarbonisation. The NBD can dispel these myths and the confusion they cause if they are unknowingly perpetuated. Nine myths are described and disproved based on arguments and data from the NBD. Light is thrown on the true nature of the British building stock, in particular non-domestic and mixed-use buildings. New perspectives and methods of analysis are possible with a database that covers all buildings. POLICY RELEVANCE The NBD has been designed to support better evidenced development and targeting of policies and regulation on buildings. It allows for specific segments and subsets of the stock to be analysed. The rich detail combining geometry, building attributes, and activity allows for policy options to be developed and assessed based on the actual premises and their features. The spatial nature of the data allows for localised energy planning and decarbonisation action. Some of the ‘myths’, if acted on, could lead to wasteful or misdirected policies. Examples are given, including one that directly illustrates a case of the NBD being used to correct previous policy assumptions. The NBD makes it possible to avoid these dangers. Data from the NBD have been made publicly available, so that local authorities, community groups, and consulting and industrial firms can have a firmer statistical basis on which to make policies and plans.

14 May 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
JPJason Palmer
Jason Palmer
SESteve Evans
Steve Evans
DHDominic Humphrey
Dominic Humphrey
PRPaul Ruyssevelt
Paul Ruyssevelt
SAShyam Amrith
Shyam Amrith
NTNicola Terry
Nicola Terry
Great Britain has a temperate climate, but like other countries, its weather patterns have already been profoundly affected by climate change, and the changes are very likely to continue for decades. It also has an older building stock than most other countries, which may mean it is more difficult to adapt the built environment to reduce vulnerability to climate hazards. However, Great Britain has excellent mapping and buildings data. The built environment is better described than most other countries, and the authors’ work on the National Buildings Database for Great Britain, which draws together the most reliable sources of data covering non-domestic buildings in England, Scotland and Wales, provides an unparalleled opportunity to evaluate how many people will be affected by climate hazards. There has been considerable research effort assessing how housing will be affected by climate change, but so far much less systematic assessment of impacts on non-domestic buildings. Here, the authors examine three aspects of climate hazard affecting people in non-domestic buildings in Great Britain: (1) Overheating—How many and what types of non-domestic buildings are vulnerable to overheating risks in a heat wave? What total floor area is affected, and how many people typically occupy these buildings? (2) Flooding—How many and what types of non-domestic buildings are threatened by flooding now and in 2080? How much floorspace is threatened, and how many people typically occupy these buildings? (3) Safe space—How much air-conditioned ‘safe space’ is available where people vulnerable to overheating risks could retreat to in an emergency overheating event (e.g., schools or hospitals)? How many people could be accommodated, and what fraction of the total GB working population does this represent? We propose five new metrics to assess two of the immediate hazards posed by climate change (overheating and flooding) and to begin to assess to what extent Great Britain could find temporary accommodation for people displaced by these hazards.