Aims: Most of the criteria used to diagnose direct capture of the left bundle branch (LBB) have never been validated in an external sample. We hypothesized that lead aVL might add relevant information, and the combination of several electrocardiograph (ECG)-based criteria might discriminate better LBB capture from left ventricular septal (LVS) capture, than each criterion separately.Methods and results: Single-centre study involving all consecutive patients who received LBB area pacing. LBB capture was defined according to QRS morphology transition criteria during decremental pacing. Multivariate logistic regression analysis was performed to develop a predictive score for LBB capture. A total of 71 patients with confirmed LBB capture were analysed. The optimal cut-off values of R wave peak time (RWPT) in lead V6 (V6-RWPT) and V6-V1 interpeak interval for the discrimination of LBB capture were <83 ms and ≥33 ms, respectively. The RWPT in lead aVL (aVL-RWPT) showed a good discrimination power for the differential diagnosis of LBB capture and LVS capture. The optimal value for aVL-RWPT was 79 ms [sensitivity (SN) and specificity (SP) of 71.2% and 88.4%, respectively]. A new score, with a good diagnostic performance (area under the curve of 0.976), was constructed gathering the information from V6-RWPT, aVL-RWPT, and V6-V1 interpeak interval. The optimal score of 3 points showed a SN and SP of 89.2% and 100%, respectively for the differentiation of LBB capture.Conclusions: ECG-based criteria are useful to confirm the capture of the LBB. The combination of V6-RWPT, aVL-RWPT, and V6-V1 interpeak interval values demonstrated better diagnostic performance than isolated measurements.
Aims: Left bundle branch area pacing (LBBAP) electrical performance is well documented. Nevertheless, the long-term mechanical implications, and differences between left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP), remain unclear. This study assessed mechanical performance of LBBAP in a mid- to long-term post-implantation setting and compared capture types. Methods and results: In this prospective, single-centre study, 88 patients with preserved left ventricular ejection fraction and successful LBBAP underwent paired echocardiography during intrinsic and paced rhythm (median 18 months post-implant). Two-dimensional, speckle-tracking and myocardial work (MW) indices were analysed. Adjusted linear mixed-effects models for repeated measures compared LBBAP vs. intrinsic rhythm and LBBP vs. LVSP differences. Independent predictors of changes in MW indices were sought with multivariate regression. Left bundle branch area pacing showed lower left ventricular volumes than intrinsic rhythm and a decrease in global longitudinal strain (16.2% vs. 16.8%, P = 0.040). Global constructive work (2232.8 vs. 2028.8 mmHg%, P < 0.001) and global wasted work (266.2 vs. 219.1 mmHg%, P = 0.003) were higher during pacing, without differences in global work index (1607.8 vs. 1536.7 mmHg%, P = 0.171) or global work efficiency (GWE) (88.3% vs. 89.3%, P = 0.092). Between LBBP (n = 63) and LVSP (n = 25), no statistically significant differences were found in any parameter after covariate adjustment (all P > 0.28). In multivariate analysis, LVSP independently predicted modest GWE decrease. Conclusion: In patients with preserved LVEF, LBBAP maintains global mechanical performance comparable to intrinsic rhythm while increasing constructive and wasted work. Mechanical performance is largely similar between LBBP and LVSP, supporting the physiological value of LBBAP regardless of capture type.