Álvaro Estévez Paniagua

Álvaro Estévez Paniagua

Auto-generated profile, based on publicly available information

Álvaro Estévez Paniagua

Cardiology Department. Hospital Infanta Leonor Hospital. Gran Vía del Este, 28030, Madrid, Spain

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2023 in Heart Rhythm
Verified
Journal Article
Closed access
SFSem Briongos Figuero
Sem Briongos Figuero
ÁEÁlvaro Estévez-Paniagua
Álvaro Estévez-Paniagua
ASAna Sánchez-Hernández
Ana Sánchez-Hernández
DHDelia Heredero-Palomo
Delia Heredero-Palomo
ESElena Sánchez-López
Elena Sánchez-López
RMRoberto Muñoz-Aguilera
Roberto Muñoz-Aguilera

14 July 2023 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
SFSem Briongos Figuero
Sem Briongos Figuero
ÁPÁlvaro Estévez Paniagua
Álvaro Estévez Paniagua
AHAna Sánchez Hernández
Ana Sánchez Hernández
RMRoberto Muñoz-Aguilera
Roberto Muñoz-Aguilera
Background: QRS transition criteria during dynamic manoeuvers are the gold-standard for non-invasive confirmation of left bundle branch (LBB) capture, but they are seen in <50% of LBB area pacing (LBBAP) procedures.Objective: We hypothesized that transition from left ventricular septal pacing (LVSP) to LBB pacing (LBBP), when observed during lead penetration into the deep interventricular septum (IVS) with interrupted pacemapping, can suggest LBB capture.Methods: QRS transition during lead screwing-in was defined as shortening of paced V6-R wave peak time (RWPT) by ≥10 ms from LVSP to non-selective LBBP (ns-LBBP) obtained during mid to deep septal lead progression at the same target area, between two consecutive pacing manoeuvres. ECG-based criteria were used to compared LVSP and ns-LBBP morphologies obtained by interrupted pacemapping.Results: Sixty patients with demonstrated transition from LVSP to ns-LBBP during dynamic manoeuvers were compared to 44 patients with the same transition during lead screwing-in. Average shortening in paced V6-RWPT was similar among study groups (17.3 ± 6.8 ms vs. 18.8 ± 4.9 ms for transition during dynamic manoeuvres and lead screwing-in, respectively; p = 0.719). Paced V6-RWPT and aVL-RWPT, V6-V1 interpeak interval and the recently described LBBP score, were also similar for ns-LBBP morphologies in both groups. LVSP morphologies showed longer V6-RWPT and aVL-RWPT, shorter V6-V1 interpeak interval and lower LBBP score punctuation, without differences among the two QRS transition groups. V6-RWPT < 75 ms or V6-V1 interpeak interval > 44 ms criterion was more frequently achieved in ns-LBBP morphologies obtained during lead screwing-in compared to those obtained during dynamic manoeuvres (70.5% vs. 50%, respectively p = 0.036).Conclusions: During LBBAP procedure, QRS transition from LVSP to ns-LBBP can be observed as the lead penetrates deep into the IVS with interrupted pacemapping. Shortening of at least 10 ms in paced V6-RWPT may serve as marker of LBB capture.

29 October 2025 in EP Europace
Verified
Journal Article
Open access
ÁPÁlvaro Estévez Paniagua
Álvaro Estévez Paniagua
SFSem Briongos Figuero
Sem Briongos Figuero
MMManuel Tapia Martínez
Manuel Tapia Martínez
SLSilvia Jiménez Loeches
Silvia Jiménez Loeches
AHAna Sánchez Hernández
Ana Sánchez Hernández
RMRoberto Muñoz-Aguilera
Roberto Muñoz-Aguilera
Aims: Left bundle branch area pacing (LBBAP) electrical performance is well documented. Nevertheless, the long-term mechanical implications, and differences between left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP), remain unclear. This study assessed mechanical performance of LBBAP in a mid- to long-term post-implantation setting and compared capture types. Methods and results: In this prospective, single-centre study, 88 patients with preserved left ventricular ejection fraction and successful LBBAP underwent paired echocardiography during intrinsic and paced rhythm (median 18 months post-implant). Two-dimensional, speckle-tracking and myocardial work (MW) indices were analysed. Adjusted linear mixed-effects models for repeated measures compared LBBAP vs. intrinsic rhythm and LBBP vs. LVSP differences. Independent predictors of changes in MW indices were sought with multivariate regression. Left bundle branch area pacing showed lower left ventricular volumes than intrinsic rhythm and a decrease in global longitudinal strain (16.2% vs. 16.8%, P = 0.040). Global constructive work (2232.8 vs. 2028.8 mmHg%, P < 0.001) and global wasted work (266.2 vs. 219.1 mmHg%, P = 0.003) were higher during pacing, without differences in global work index (1607.8 vs. 1536.7 mmHg%, P = 0.171) or global work efficiency (GWE) (88.3% vs. 89.3%, P = 0.092). Between LBBP (n = 63) and LVSP (n = 25), no statistically significant differences were found in any parameter after covariate adjustment (all P > 0.28). In multivariate analysis, LVSP independently predicted modest GWE decrease. Conclusion: In patients with preserved LVEF, LBBAP maintains global mechanical performance comparable to intrinsic rhythm while increasing constructive and wasted work. Mechanical performance is largely similar between LBBP and LVSP, supporting the physiological value of LBBAP regardless of capture type.

30 July 2024 in Indian Pacing and Electrophysiology Journal
Verified
Journal Article
Open access
ÁPÁlvaro Estévez Paniagua
Álvaro Estévez Paniagua
SFSem Briongos Figuero
Sem Briongos Figuero
AHAna Sánchez Hernández
Ana Sánchez Hernández
RMRoberto Muñoz-Aguilera
Roberto Muñoz-Aguilera
Variation in human left bundle branch (LBB) anatomy has a significant effect on the sequence of left ventricular depolarization. However, little is known regarding the electrophysiological characteristics of pacing different LBB fascicles. We aimed to analyse the different electrocardiographic characteristics of LBB pacing (LBBP) attending to the site of pacing at the LBB system. In 200 consecutive patients with confirmed LBBP, we distinguished left bundle trunk capture (LBTP) from any LB fascicular pacing (LBFP) based on the presence of LB potentials and paced QRS morphologies. We compared them regarding procedure, LBBP criteria and electrical synchrony parameters. One hundred and seventy-three patients with LBFP were compared to 25 patients with LBTP. Left septal and posterior fascicles were significantly more prevalent than left anterior in LBFP (46.8%, 41.0% and 12.2% respectively). QRS transition criteria (80.0% vs 61.8%; p=0.077), selective LBBP (40.0 vs 21.5%; p=0.101), paced QRS width (110.3±16.8 ms vs 115.4±14.9 ms; p=0.117), V6-RWPT (79.2±10.7 ms vs 75.3±9.7 ms; p=0.068) and interpeak interval (42.5±19.1 ms vs 45.7±12.9 ms; p=0.282) were not significantly different between LBTP and LBFP. All short-term complications occurred in LBFP, mainly driven by septal perforations (n=23), without any difference in the pacing parameters. Among the LBFP subgroups, only aVL-RWPT was longer when the posterior fascicle was paced. LBFP is much more prevalent than LBTP in unselected consecutive patients with LBBP. LBFP seems more feasible, and as good as LBTP in terms of electrical synchrony and pacing safety.

19 February 2025 in JACC: Case Reports
Verified
Journal Article
Open access
ÁEÁlvaro Estévez-Paniagua
Álvaro Estévez-Paniagua
SBSem Briongos-Figuero
Sem Briongos-Figuero
RMRoberto Muñoz-Aguilera
Roberto Muñoz-Aguilera
ZGZaira Gómez-Álvarez
Zaira Gómez-Álvarez
LSLuisa Salido-Tahoces
Luisa Salido-Tahoces
ASAngel Sanchez-Recalde
Angel Sanchez-Recalde
Techniques for tricuspid regurgitation repair are advancing rapidly. Post-procedure rhythm disorders have been reported, although they are quite unknown. Choosing the type of pacing can be challenging. We present a patient with slow atrial fibrillation and syncope secondary to asystole, following transcatheter tricuspid valve replacement, who underwent His bundle pacing.

8 September 2025 in Heart Rhythm
Verified
Journal Article
Closed access
SFSem Briongos Figuero
Sem Briongos Figuero
ÁPÁlvaro Estévez Paniagua
Álvaro Estévez Paniagua
MMManuel Tapia Martínez
Manuel Tapia Martínez
AHAna Sánchez Hernández
Ana Sánchez Hernández
SLSilvia Jiménez Loeches
Silvia Jiménez Loeches
RMRoberto Muñoz-Aguilera
Roberto Muñoz-Aguilera