6 August 2024 in Beilstein Journal of Nanotechnology
Over the last few decades, field-effect transistor (FET)-based biosensors have demonstrated great potential across various industries, including medical, food, agriculture, environmental, and military sectors. These biosensors leverage the electrical properties of transistors to detect a wide range of biomolecules, such as proteins, DNA, and antibodies. This article presents a comprehensive review of advancements in the architectures of FET-based biosensors aiming to enhance device performance in terms of sensitivity, detection time, and selectivity. The review encompasses an overview of emerging FET-based biosensors and useful guidelines to reach the best device dimensions, favorable design, and realization of FET-based biosensors. Consequently, it furnishes researchers with a detailed perspective on design considerations and applications for future generations of FET-based biosensors. Finally, this article proposes intriguing avenues for further research on the topology of FET-based biosensors.
2 July 2021 in Measurement Science and Technology
Accurate measurement of blood pressure (BP) is of great importance in a medical diagnostic. It can be obtained by different methods. Nowadays, most BP devices use the oscillometric method which estimates systolic and diastolic BP through different algorithms. Unfortunately, the precision of these devices is always questioned and doctors prefer the use of traditional auscultatory-based methods. In this paper, a new oscillometric method for BP measurement is proposed. In fact, the proposed method is based on the design of a BP device which first detects and maintains the cuff pressure at the level of mean BP then the continuous determination of systolic and diastolic BP. device was assessed by measuring the systolic and diastolic BP on 20 healthy volunteers. The measured pressures were compared with those obtained by two commercially available BP devices. The results show a very high correlation coefficient ( r = 0.97), an almost perfect agreement coefficient (kappa = 0.81), and a low mean absolute error (3.43 mmHg). The proposed methodology has a high probability to be complied with the Association for the Advancement of Medical Instrumentation and the British Hypertension Society (Grade A) standards, and can greatly improve the measurement of blood pressure using the oscillometric approach.
12 July 2024 in International Journal of High Speed Electronics and Systems