1 October 2026 in Superconductor Science and Technology
A helium-free fast-ramping dipole–quadrupole combined-function superconducting magnet based on discrete cosine theta coils was developed for compact heavy-ion therapy gantry applications. Under rapid excitation conditions, significant AC losses and eddy-current losses are generated in both superconducting coils and conductive structures, posing challenges to thermal stability under conduction cooling. In this work, the AC-loss distribution was evaluated using a spatially resolved method combining the spatial resolution loss analysis method and the position–field-strength integration method. Based on the calculated heat-load distribution, a 3D ring–axis–radial conduction-cooling structure was designed and optimized to enhance thermal transport while suppressing eddy-current losses. Electromagnetic–thermal coupled simulations and experimental investigations were carried out to analyze the steady-state and transient thermal behavior under cyclic fast-ramping operation. The results show that the total dynamic loss is approximately 6.4 W under practical operating conditions with a ramp rate of 0.6 T s −1 . The maximum temperature rise is limited to below 0.6 K during continuous operation and remains within 0.2 K under realistic cyclic excitation conditions. Experimental measurements obtained from both liquid-helium and conduction-cooled tests show satisfactory agreement with numerical predictions, providing experimental support for the proposed thermal management scheme. The present work demonstrates the feasibility of helium-free fast-ramping superconducting gantry magnets for next-generation compact heavy-ion therapy systems.