Kota Aoyagi

Kota Aoyagi

Auto-generated profile, based on publicly available information

Kota Aoyagi

Research and Development Center, Canon Medical Systems Corporation, 1385 Shimoishigami, Otawara-Shi, Tochigi, 324-8550, Japan

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 August 2020 in Radiology
Verified
Journal Article
Closed access
YOYoshiharu Ohno
Yoshiharu Ohno
KAKota Aoyagi
Kota Aoyagi
AYAtsushi Yaguchi
Atsushi Yaguchi
SSShinichiro Seki
Shinichiro Seki
YUYoshiko Ueno
Yoshiko Ueno
TYTakeshi Yoshikawa
Takeshi Yoshikawa
A convolutional neural network combined with computer-aided detection of pulmonary nodule volume at CT showed that nodule volume change per day was a better predictor of malignancy than was nodule ... Background Deep learning may help to improve computer-aided detection of volume (CADv) measurement of pulmonary nodules at chest CT. Purpose To determine the efficacy of a deep learning method for ...

12 October 2021 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
YOYoshiharu Ohno
Yoshiharu Ohno
KAKota Aoyagi
Kota Aoyagi
DTDaisuke Takenaka
Daisuke Takenaka
TYTakeshi Yoshikawa
Takeshi Yoshikawa
YFYasuko Fujisawa
Yasuko Fujisawa
HTHiroshi Toyama
Hiroshi Toyama
Background: The need for quantitative assessment of interstitial lung involvement on thin-section computed tomography (CT) has arisen in interstitial lung diseases including connective tissue disease (CTD). Purpose: To evaluate the capability of machine learning (ML)-based CT texture analysis for disease severity and treatment response assessments in comparison with qualitatively assessed thin-section CT for patients with CTD. Material and Methods: A total of 149 patients with CTD-related ILD (CTD-ILD) underwent initial and follow-up CT scans (total 364 paired serial CT examinations), pulmonary function tests, and serum KL-6 level tests. Based on all follow-up examination results, all paired serial CT examinations were assessed as “Stable” (n = 188), “Worse” (n = 98) and “Improved” (n = 78). Next, quantitative index changes were determined by software, and qualitative disease severity scores were assessed by consensus of two radiologists. To evaluate differences in each quantitative index as well as in disease severity score between paired serial CT examinations, Tukey's honestly significant difference (HSD) test was performed among the three statuses. Stepwise regression analyses were performed to determine changes in each pulmonary functional parameter and all quantitative indexes between paired serial CT scans. Results: Δ% normal lung, Δ% consolidation, Δ% ground glass opacity, Δ% reticulation, and Δdisease severity score showed significant differences among the three statuses ( P < 0.05). All differences in pulmonary functional parameters were significantly affected by Δ% normal lung, Δ% reticulation, and Δ% honeycomb (0.16 ≤r2 ≤0.42; P < 0.05). Conclusion: ML-based CT texture analysis has better potential than qualitatively assessed thin-section CT for disease severity assessment and treatment response evaluation for CTD-ILD.

1 September 2024 in Radiology
Verified
Journal Article
Closed access
AHAkinori Hata
Akinori Hata
KAKota Aoyagi
Kota Aoyagi
THTakuya Hino
Takuya Hino
MKMasami Kawagishi
Masami Kawagishi
NWNoriaki Wada
Noriaki Wada
HHHiroto Hatabu
Hiroto Hatabu
An automated interstitial lung abnormality identification model incorporating both a section inference model and a case inference model resulted in an area under the receiver operating characteristic curve of 0.87.

11 December 2025 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
YNYusei Nakamura
Yusei Nakamura
TFTaiki Fukuda
Taiki Fukuda
KAKota Aoyagi
Kota Aoyagi
MKMasami Kawagishi
Masami Kawagishi
YKYuki Ko
Yuki Ko
HHHiroto Hatabu
Hiroto Hatabu
Purpose: An artificial intelligence (AI) system for detecting interstitial lung abnormalities (ILA) was previously developed but requires external validation. This study aimed to examine the robustness across different populations and investigate associations between the system outputs and traction bronchiectasis/bronchiolectasis severity patterns. Materials and methods: CT scans from population-based samples of the Rotterdam Study (2018–2019) and the Age Gene/Environment Susceptibility Reykjavik (AGES-Reykjavik) Study (baseline CT: 2002–2006, follow-up CT: 2007–2011) were used in this secondary analysis of the two cohorts. The AI system calculated ILA probability score (AI score) in the range from 0 to 1. Three experienced readers evaluated independently all CT scans for ILA, and two chest radiologists assessed traction bronchiectasis/bronchiolectasis using the 4-scale traction bronchiectasis/bronchiolectasis index (TBI) for severity by consensus. Receiver operating characteristic (ROC) analysis and Kruskal–Wallis test were used for statistical analysis. Results: The system analyzed 932 CT scans of the Rotterdam Study (mean participant age, 79.6 years ± 4.3 (SD), 482 women) and 5242 CT scans of the AGES-Reykjavik Study (mean participant age, 76.4 years ± 5.6, 3032 women), and achieved area under the ROC curve of 0.841 (95% CI 0.804, 0.879) and 0.823 (95% CI 0.798, 0.847), respectively. AI scores correlated with readers’ certainty, decreasing from unanimous ILA cases to No-ILA cases. Higher baseline AI scores correlated with greater severity of traction bronchiectasis/bronchiolectasis (TBI-3: 0.931 [IQR, 0.911–0.932], TBI-2: 0.738 [IQR, 0.406–0.880], TBI-1: 0.537 [IQR, 0.317–0.761], TBI-0: 0.250 [IQR, 0.136–0.455]). Conclusion: The system demonstrated robust ILA detection performance across different populations, with AI scores showing associations with traction bronchiectasis/bronchiolectasis severity.

3 March 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
GAGakuto Aoyama
Gakuto Aoyama
ZZZhexin Zhou
Zhexin Zhou
HYHong Yang
Hong Yang
YLYufei Li
Yufei Li
BHBing Han
Bing Han
KAKota Aoyagi
Kota Aoyagi
Aims : Preoperative observation of computed tomography (CT) cross sections corresponding to standard transesophageal echocardiographic (TEE) views is useful for treatments using TEE. However, manually locating those CT cross sections from the CT volume is time consuming. This study aimed to develop a fully automatic method to locate those CT cross sections corresponding to standard TEE views. Methods : Developed method crops CT volume based on the heart segmentation model if input is a chest CT. CT cross sections corresponding to standard TEE views are coarsely located from cropped chest CT or cardiac CT based on the esophagus segmentation model and the plane localization model. The coarse cross sections are refined based on the anatomical landmark detection model. Accuracies of located CT cross sections were evaluated by five-fold cross validation with comparison to manually set cross sections, using 110 CT volumes. The results were also compared to the top and the middle axial section of the heart as baselines. Results : The mean of rotation error, probe position error, landmark error and structural similarity index between the predicted and manually set cross sections were 12.52 ± 8.27 degree, 13.90 ± 10.62 mm, 3.95 ± 3.48 mm and 0.64 ± 0.15, respectively, and these errors were significantly smaller than the baselines. The mean processing time was 41.34 ± 22.75 s. Conclusions : Our developed method can provide CT cross sections corresponding to standard TEE views without user operations, resulting in faster treatment planning with less effort and without inter user variability in treatments using TEE.