Purpose: To prospectively compare the capability for bone metastasis assessment of whole‐body diffusion‐weighted imaging (DWI), magnetic resonance imaging (MRI) without and with DWI, [18F] fluoro‐2‐D‐glucose positron emission tomography with computed tomography (FDG‐PET/CT) and bone scintigraphy in non‐small cell carcinoma (NSCLC) patients.Materials and Methods: In all, 115 consecutive NSCLC patients (66 men, 49 women; mean age 72 years) prospectively underwent whole‐body MRI, PET/CT, and bone scintigraphy before treatment. For each method, probability of metastasis was independently assessed by using a 5‐point visual scoring system on a per‐site basis. Receiver operating characteristic (ROC)‐based positive tests were used to determine the practical threshold value for each method on a per‐site basis. Sensitivities, specificities, and accuracies were then compared on a per‐site and per‐patient basis by means of McNemar's test.Results: When the practical threshold values were adapted, specificity and accuracy of whole‐body MRI with DWI were significantly higher than those of bone scintigraphy and PET/CT (P < 0.05). On a per‐patient basis, specificity and accuracy of whole‐body MRI with DWI were significantly higher than those of bone scintigraphy (P < 0.05).Conclusion: Whole‐body MRI with DWI can be used for bone metastasis assessment of NSCLC patients as accurate as bone scintigraphy and/or PET/CT. J. Magn. Reson. Imaging 2009;30:298–308.
Pulmonary MRI with ultrashort echo time was comparable to standard- or low-dose CT for Lung CT Screening Reporting and Data System classification in a screening population. Background Pulmonary MRI with ultrashort echo time (UTE) has been compared with chest CT for nodule detection and classification. However, direct comparisons of these methods’ capabilities for Lung...
OBJECTIVE. The objective of our study was to prospectively compare the capability of dynamic area-detector CT analyzed with different mathematic methods and PET/CT in the management of pulmonary nodules. SUBJECTS AND METHODS. Fifty-two consecutive patients with 96 pulmonary nodules underwent dynamic area-detector CT, PET/CT, and microbacterial or pathologic examinations. All nodules were classified into the following groups: malignant nodules (n = 57), benign nodules with low biologic activity (n = 15), and benign nodules with high biologic activity (n = 24). On dynamic area-detector CT, the total, pulmonary arterial, and systemic arterial perfusions were calculated using the dual-input maximum slope method; perfusion was calculated using the single-input maximum slope method; and extraction fraction and blood volume (BV) were calculated using the Patlak plot method. All indexes were statistically compared among the three nodule groups. Then, receiver operating characteristic analyses were used to compare the diagnostic capabilities of the maximum standardized uptake value (SUVmax) and each perfusion parameter having a significant difference between malignant and benign nodules. Finally, the diagnostic performances of the indexes were compared by means of the McNemar test. RESULTS. No adverse effects were observed in this study. All indexes except extraction fraction and BV, both of which were calculated using the Patlak plot method, showed signifi-cant differences among the three groups (p < 0.05). Areas under the curve of total perfusion calculated using the dual-input method, pulmonary arterial perfusion calculated using the dual-input method, and perfusion calculated using the single-input method were significantly larger than that of SUVmax (p < 0.05). The accuracy of total perfusion (83.3%) was significantly greater than the accuracy of the other indexes: pulmonary arterial perfusion (72.9%, p < 0.05), systemic arterial perfusion calculated using the dual-input method (69.8%, p < 0.05), perfusion (66.7%, p < 0.05), and SUVmax (60.4%, p < 0.05). CONCLUSION. Dynamic area-detector CT analyzed using the dual-input maximum slope method has better potential for the diagnosis of pulmonary nodules than dynamic area-detector CT analyzed using other methods and than PET/CT.
A convolutional neural network combined with computer-aided detection of pulmonary nodule volume at CT showed that nodule volume change per day was a better predictor of malignancy than was nodule ... Background Deep learning may help to improve computer-aided detection of volume (CADv) measurement of pulmonary nodules at chest CT. Purpose To determine the efficacy of a deep learning method for ...