Dandan Sheng

Dandan Sheng

Auto-generated profile, based on publicly available information

Dandan Sheng

Sports Medicine Institute of Fudan University, Department of Sports Medicine, Huashan Hospital, Fudan University, Shanghai, 200040, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2019 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
DSDandan Sheng
Dandan Sheng
JLJinxiu Li
Jinxiu Li
CAChengchong Ai
Chengchong Ai
SFSijia Feng
Sijia Feng
TYTing Ying
Ting Ying
SCShiyi Chen
Shiyi Chen
Tendons can transmit mechanical force from muscles to bones for movement. However, the mechanical strength of tendons is compromised after surgery, thus causing a high rate of tendon retear. Hence, the design and preparation of biodegradable materials with excellent mechanical properties have become an urgent demand for sports medicine. In this study, biomimetic polycaprolactone (PCL)/gelatin (Gel)-aligned scaffolds were fabricated for the mechanical restoration of the injured tendon in a rabbit model. The diameter of nanofibers was about 427.82 ± 56.99 nm, which was approximate to that of the native collagen fibrils; the directional consistency of the nanofibers in PCL/Gel-aligned scaffolds reached 77.33 ± 3.22%, which were ultrastructurally biomimetic. Compared to the observations for the control group, the in vitro mechanical results showed that the PCL/Gel-aligned scaffolds (P/G-A) were anisotropic in terms of failure load, tensile strength, and Young's modulus. After verifying their good cytocompatibility, the scaffolds were implanted into the rabbit patellar tendon in situ. The biomechanical properties of the repaired tendon in P/G-A reached 343.97 ± 65.30 N in failure load, 85.99 ± 16.33 MPa in tensile strength, 590.84 ± 201.87 MPa in Young's modulus, and 171.29 ± 61.50 N mm−1 in stiffness in vivo at 8 weeks post operation. In a word, our results demonstrated that P/G-A could support the regenerated tissue of injured patellar tendons to restore the biomechanical strength in a rabbit model. This suggested that the PCL/Gel-aligned scaffolds can pave a promising way to improve the healing of injured tendons in the clinic in the future.

1 June 2018 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
SWSiheng Wang
Siheng Wang
YGYunshen Ge
Yunshen Ge
CAChengchong Ai
Chengchong Ai
JJJia Jiang
Jia Jiang
JCJiangyu Cai
Jiangyu Cai
SCShiyi Chen
Shiyi Chen
Purpose: This study was designed to evaluate the biocompatibility and osseointegration of polyethylene terephthalate ligament after coating with hydroxyapatite (PET/HA) by using the plasma spraying technique in vitro and in vivo. Methods: In this study, PET/HA sheets were prepared by using the plasma spraying technique. The characterization, the viability of bone marrow stromal cells (BMSCs), and the mRNA expression of bone formation-related genes were evaluated in vitro. The osseointegration in vivo was investigated in the rabbit anterior cruciate ligament (ACL) reconstruction model by micro-computed tomography (micro-CT) analysis, histological evaluation, and biomechanical tests. Results: Scanning electron microscopy (SEM) results showed that the surface of polyethylene terephthalate (PET) becomes rough after spraying with hydroxyapatite (HA) nanoparticles, and the water contact angle was 75.4°±10.4° in the PET/HA-plasma group compared to 105.3°±10.9° in the control group (p<0.05). The cell counting kit-8 counting results showed that the number of BMSCs significantly increased in the PET/HA-plasma group (p<0.05). Reverse transcription polymerase chain reaction (RT-PCR) results showed that there was an upregulated mRNA expression of bone formation-related genes in the PET/HA-plasma group (p<0.05). Micro-CT results showed that the transactional area of tibial tunnels and femoral tunnels was smaller in the PET/HA-plasma group (p<0.05). The histological evaluation scores of the PET/HA-plasma group were significantly superior to those of the PET control group at 8 and 12 weeks (p<0.05). The biomechanical tests showed an increased maximum load to failure and stiffness in the PET/HA-plasma group compared to those in the control group at 8 and 12 weeks. Conclusion: Both in vitro and in vivo results demonstrated in this study suggest that the biocompatibility and osseointegration of PET/HA ligament were significantly improved by increasing the proliferation of cells and upregulating the expression of bone formation-related genes. In a word, the PET/HA-plasma ligament is a promising candidate for ACL reconstruction in future.

1 October 2017 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
CAChengchong Ai
Chengchong Ai
DSDandan Sheng
Dandan Sheng
JCJun Chen
Jun Chen
JCJiangyu Cai
Jiangyu Cai
SWSiheng Wang
Siheng Wang
SCShiyi Chen
Shiyi Chen
Surface modification of vascular endothelial growth factor-loaded silk fibroin to improve biological performance of ultra-high-molecular-weight polyethylene via promoting angiogenesis Chengchong Ai, Dandan Sheng, Jun Chen, Jiangyu Cai, Siheng Wang, Jia Jiang, Shiyi Chen Department of Sports Medicine, Huashan Hospital, Fudan University, Shanghai, People’s Republic of China Ultra-high-molecular-weight polyethylene (UHMWPE) has been applied in orthopedics, as the materials of joint prosthesis, artificial ligaments, and sutures due to its advantages such as high tensile strength, good wear resistance, and chemical stability. However, postoperative osteolysis induced by UHMWPE wear particles and poor bone–implant healing interface due to scarcity of osseointegration is a significant problem and should be solved imperatively. In order to enhance its affinity to bone tissue, vascular endothelial growth factor (VEGF) was loaded on the surface of materials, the loading was performed by silk fibroin (SF) coating to achieve a controlled-release delivery. Several techniques including field emission scanning electron microscopy (FESEM) and attenuated total reflectance (ATR)-Fourier transform infrared (FTIR) and water contact angle measurement were used to validate the effectiveness of introduction of SF/VEGF. The result of ELISA demonstrated that the release of VEGF was well maintained up to 4 weeks. The modified UHMWPE was evaluated by both in vitro and in vivo experiments. According to the results of FESEM and cell counting kit-8 (CCK-8) assay, bone marrow mesenchymal stem cells cultured on the UHMWPE coated with SF/VEGF and SF exhibited a better proliferation performance than that of the pristine UHMWPE. The model rabbit of anterior cruciate ligament reconstruction was used to observe the graft–bone healing process in vivo. The results of histological evaluation, microcomputed tomography (micro-CT) analysis, and biomechanical tests performed at 6 and 12 weeks after surgery demonstrated that graft–bone healing could be significantly improved due to the effect of VEGF on angiogenesis, which was loaded on the surface by SF coating. This study showed that the method loading VEGF on UHMWPE by SF coating played an effective role on the biological performance of UHMWPE and displayed a great potential application for anterior cruciate ligament reconstruction. Keywords: UHMWPE, surface modification, VEGF, silk fibroin, graft–bone healing

1 July 2021 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
WJWenhe Jin
Wenhe Jin
JCJiangyu Cai
Jiangyu Cai
DSDandan Sheng
Dandan Sheng
XLXingwang Liu
Xingwang Liu
JCJUN CHEN
JUN CHEN
SCShiyi Chen
Shiyi Chen
Tunnel position deicide the isometry of graft attachment in synthetic anterior cruciate ligament (ACL) reconstruction. Near-isometric tunnel position may have advantage in graft integration and knee function in ACL reconstruction (ACLR) with polyethylene terephthalate (PET) ligament. Few studies focused on tunnel position isometry when conduct ACLR with an animal model. This study aimed to establish a preclinical rabbit model of near and non isometric ACLR with PET ligament and investigate the advantage of near-isometric ACLR compared to non-isometric ACLR. Nine hind limbs of rabbit were used in tunnel position study. Two femoral(anatomic, nonanatomic) tunnels and three tibial(anterior, middle, posterior) tunnels were used to measure tunnel position isometry during knee full range of motion. The tunnel position combination with minimal isometry was considered as near-isometric tunnel position. Then, 48 rabbits divided into two groups were conducted near or non isometric ACLR with PET ligament with graft fixation angle of 30° and constant tension of 5N. PET ligament isometry, range of motion(ROM) restriction, knee laxity were recorded after operation and followed up with macroscopic observation, microcomputed tomography (micro-CT) analysis, histology assessment and biomechanical test at 4 and 8 weeks postoperatively. The tunnel combination with minimal isometry was femoral anatomic position and tibial posterior position(5.19 ​± ​1.78%) and considered as near-isometric tunnel position. ROM restriction were observed in non-isometric group (22.50 ​± ​14.14°) while none in near-isometric group. However, no ROM restriction observed at 8 weeks in both group. Knee laxity compared to contralateral knee were better in near-isometric group than non-isometric group (stable/slack/total 10/2/12 VS 3/9/12, p ​= ​0.012) at 8 weeks postoperatively. Supeiror PET ligament integration were also observed in near-isometric group through macroscopic observation, micro-CT analysis, histology assessment at both 4 and 8 weeks. The failure load in the Near-Isometric group at 8 weeks were higher than timezero reconstruction with statistical difference (156.8N ​± ​25.98N vs.102.6 ​± ​22.96N, p ​= ​0.02). A rabbit model of ACLR based on tunnel position isometry was successfully established in this study. The near-isometric tunnel position in rabbit model was femoral anatomic position and tibial posterior position. A near-isometric ACLR with PET ligament did not cause ROM restriction and had a better graft integration and follow-up stability than non-isometric ACLR with ROM restriction. The study demonstrate the establishmentof near-isometric tunnel position and non-isometric tunnel position with significant difference of ROM restriction and graft-bone integration. The described tunnel positions with differential isometry in a rabbit ACLR provides a reproducible and translational small animal model and enables preclinical research between tunnel position isometry and its affection on variable grafts, graft integration and knee function.

13 September 2024 in Heliyon
Verified
Journal Article
Open access
CYChengxuan Yu
Chengxuan Yu
LSLuyi Sun
Luyi Sun
HGHan Gao
Han Gao
HSHuaixuan Sheng
Huaixuan Sheng
XFXinting Feng
Xinting Feng
JCJUN CHEN
JUN CHEN
All-suture anchor (ASA) is a special type of suture anchor. It has been used to repair rotator cuff tears (RCTs). However, mechanical properties and tendon-bone integration at different time postoperatively remains to be unclear. Mechanical testing and water contact angle measurements were conducted for ASA. In vitro biocompatibility was assessed using rat bone marrow stem cells (BMSCs), including live/dead cell staining and Cell Counting Kit-8 assays. ASA was implanted for rotator cuff repair (ASA group) in a New Zealand White rabbit model of RCTs, and a natural rotator cuff was used as a control (natural group). The animals were sacrificed, and tissue samples were harvested for biomechanical, radiographic, and histological analysis at 4, 8, and 12 weeks postoperatively. ASA was hydrophobic and had a strong mechanical property in vitro. The biocompatibility analysis showed that ASA had no effect on the viability of BMSCs. Mechanical testing in vivo revealed that a gradually improved failure load of ASA group was 118.0 ± 22.53N at 12 weeks postoperatively, which was recovered to the natural group. Micro-CT analysis indicated that an initial decrease in BMD and trabecular quality following ASA implantation, with a slight recovery observed at 12 weeks. Additionally, histological analysis showed the tendon-bone interface gradually integrated in the ASA group. A significant increase in tendon-bone interface scores was found from 4 weeks to 12 weeks. Tendon maturing score also improved in the ASA group, and Type I collagen content recovered to 18.58 ± 4.378 % at 12 weeks and no different from that of the natural group. Rotator cuff repair with ASA in a rabbit model demonstrated the capacity to enhance biomechanical properties and tendon-bone integration.

13 October 2022 in Contrast Media & Molecular Imaging
Verified
Journal Article
Open access
PDF file
HZHaojun Zhao
Haojun Zhao
DSDandan Sheng
Dandan Sheng
YCYehua Cai
Yehua Cai
YTYanlin Tang
Yanlin Tang
MLMei Li
Mei Li
PXPing Xu
Ping Xu
Objective. To investigate the efficacy of contrast‐enhanced ultrasound (CEUS) in quantitatively evaluating angiogenesis during patellar tendon healing in rats. Methods. A total of 40 Sprague–Dawley rats were used in this study. The patellar tendons of 30 rats (60 limbs) that underwent incision and suture were treated as the operation group and monitored after 7, 14, and 28 days. The normal patellar tendons of 10 rats (20 limbs) were treated as the control group and monitored on day 0. The ultrasound examination was used to evaluate the structure and blood perfusion of the patellar tendon. Immunohistochemistry was used to assess angiogenesis, and the biomechanical test was used to verify functional recovery of the patellar tendon. Results. The tendons in the operation group were significantly thickened compared with those in the control group (p < 0.01). The peak intensity (PI) in CEUS of the tendons showed a clear difference at each time point after the surgery (p < 0.01). PI increased in the operation group with a maximum on day 7, and then gradually decreased until day 28 when PI was close to the basic intensity (BI) in the control group (p > 0.05). It was consistent with the change of the CD31‐positive staining areas representing angiogenesis of the injured patellar tendons. The PI was positively correlated with the CD31‐positive staining area fraction (R = 0.849, p < 0.001). The failure load and tensile strength of the repaired patellar tendons in the operation group increased over time. The PI showed negative correlations with the failure load (R = −0.787, p < 0.001) and tensile strength (R = −0.714, p < 0.001). Conclusion. The PI in CEUS could quantitatively reflect the time‐dependent change in the blood supply of the healing site, and the PI correlated with histologic and biomechanical properties of the healing tendon. Quantitative analysis of contrast‐enhanced ultrasound could be a useful method to evaluate angiogenesis in healing tendons.