Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
Background: Because of the broad anatomic variation in the course of the axillary nerve, several cadaveric studies have investigated the acromion-axillary nerve distance and its association with the humeral length to predict the axillary nerve location. This study aimed to analyze the acromion-axillary nerve distance (AAND) and its relation to the arm length (AL) in patients who underwent internal plate fixation for proximal humerus fractures. Methods: The present prospective study involved 37 patients (15 female, 22 male; the mean age = 51 years, age range 19–76) with displaced proximal humerus fractures treated by open reduction and internal fixation. After anatomic reduction and fixation were achieved, the following parameters were measured in each patient before wound closure without making an extra incision or dissection: (1) the distance from the anterolateral edge of the acromion to the course of the axillary nerve was recorded as the acromion-axillary nerve distance and (2) the distance from the anterolateral edge of the acromion to the lateral epicondyle of the humerus was recorded as arm length. The ratio of AAND to AL was then calculated and recorded as the axillary nerve index (ANI). Results: The mean AAND was 6 ± 0.36 cm (range 5.5–6.6), and the mean arm length was 32.91 ± 2.9 cm (range 24–38). The mean axillary nerve ratio was 0.18 ± 0.02 (range 0.16 to 0.23). There was a significant moderate positive correlation between AL and AAND (p = 0.006; r = 0.447). The axillary nerve location was predictable in only 18% of the patients. Conclusion: During the anterolateral deltoid-splitting approach to the shoulder joint, 5.5 cm from the anterolateral edge of the acromion could be considered a safe zone to prevent possible axillary nerve injury.
Background: Subtrochanteric femoral shortening is used during total hip arthroplasty for high hip dislocation in developmental dysplasia of hip patients. Methods: We mechanically tested the stability of various commonly used subtrochanteric osteotomy techniques. As the equivalent of a femoral stem placed in a shortened femur without any stable fixation at the osteotomy line, 2 polyvinylchloride pipes were loosely intertwined. 4 different osteotomies (Z-subtrochanteric osteotomy, oblique-45° osteotomy, double Chevron-90° and 120° subtrochanteric osteotomy) were simulated. Torsional and axial loads were applied, and torsional stiffness was calculated for each test model. Results: Z, double Chevron-90° and 120° subtrochanteric osteotomy models demonstrated lower mean torsional stiffness than oblique-45° osteotomy. With the highest torsional stiffness oblique-45° provides the best stability for treatment of high dislocation hips when a subtrochanteric osteotomy is added. Conclusions: This matches our previous clinical experience. Oblique osteotomy may also provide higher contact surfaces in the osteotomy lines to promote bone healing.
Implant‐free press‐fit tibial fixation technique has recently gained popularity in anterior cruciate ligament reconstruction because it does not cause tunnel widening, does not cause complications associated with additional fixation materials, allows bone‐to‐bone healing, and does not cause defects in revision surgery. Bone‐patellar tendon autograft offers the advantage of direct bone‐to‐bone integration of the graft, and anterior knee pain is less expected than bone‐patellar tendon‐bone autograft. This technical report includes details of arthroscopic ACL reconstruction of patellar tendon‐tibial tubercle bone autograft distal press‐fit fixation technique. We call this the Kocabey distal press‐fit technique. Technique Video: video See video under supplementary data.