Ergün Bozdağ

Ergün Bozdağ

Auto-generated profile, based on publicly available information

Ergün Bozdağ

Department of Mechanical Engineering, Istanbul Technical University, Istanbul, Türkiye

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2022 in Injury
Verified
Journal Article
Closed access
CYCem Yildirim
Cem Yildirim
MDMehmet Demirel
Mehmet Demirel
GKGökhan Karahan
Gökhan Karahan
ECEngin Cetinkaya
Engin Cetinkaya
AMAbdülhamit Misir
Abdülhamit Misir
EBErgün Bozdağ
Ergün Bozdağ

1 January 2013 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
ACAltug Cilingir
Altug Cilingir
Hakan BilhanHakan Bilhan
Hakan Bilhan
GBGokhan Baysal
Gokhan Baysal
ESEmin Sunbuloglu
Emin Sunbuloglu
EBErgun Bozdag
Ergun Bozdag
Cilingir A, et al. J Adv Prosthodont. 2013 Nov;5(4):409-415. http://dx.doi.org/10.4047/jap.2013.5.4.409

5 January 2023 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
FKFeyzi Kılıç
Feyzi Kılıç
APAbdulkadir Polat
Abdulkadir Polat
FYFatih Yamak
Fatih Yamak
EBErgün Bozdag
Ergün Bozdag
FFFırat Fidan
Fırat Fidan
HBHakan Başar
Hakan Başar
Objective: To compare the use of cannulated screws in an inverted triangular configuration, medial buttress plates, and the combination of these 2 fixation methods in the treatment of Pauwels type 3 femoral neck fractures. Methods: Twenty-eight anatomical composite third-generation femoral bone models were divided into 4 groups. The control group (group 1) was formed with 7 third-generation intact bone models. The fracture model was created with a 70° cutting block to fit 21 Pauwels type 3 fracture configurations. Seven models were fixed with an isolated 3.5 mm one-third semi-tubular medial buttress plate (group 2), 7 were fixed in an inverted triangular configuration with 6.5 mm cannulated screws (group 3), and 7 were fixed using a combination of 6.5 mm cannulated screws and a medial buttress plate (group 4). Cyclic loading was applied using axial forces ranging from 60 N to 600 N and moments ranging from 0.7 Nm to 7.0 Nm for 500 cycles. Once the cyclic loading stage was completed, the loads were removed from the system, and the quasi-static loading stage was employed to determine the stiffness and failure forces of the system under both axial and torsional forces. Quasi-static tests were performed with an axial speed of 1.8 mm/min and a torsional speed of 4.5°/min. The biomechanical properties of all groups were examined in terms of axial stiffness, torsional stiffness, and maximum axial force parameters. Results: The stiffness values of groups 1, 2, 3, and 4 were 303 ± 35.8 N/mm, 159.6 ± 25 N/mm, 232 ± 35.9 N/mm, and 366.9 ± 58 N/mm, respectively, under axial forces (P < .01); 2172.7 ± 252.1 Nmm/°, 1225.3 ± 238.6 Nmm/°, 2123 ± 359.4 Nmm/°, and 2721.85 ± 304 Nmm/°, respectively, under torsional moments (P < .01); and 2072.1 ± 256.1 N, 1379.9 ± 290.6 N, 2099.1 ± 454.2 N, and 2648.4 ± 364.6 N, respectively, under the maximum force (P < .01). Conclusion: This study showed that in the fixation of Pauwels type 3 fractures formed on third-generation bone models, the utilization of half-thread cannulated screws in an inverted triangle configuration, along with a medial buttress plate, provided stronger fixation compared to the remaining implant groups and the control group. According to the evaluation of the parameters, the isolated application of a medial buttress plate had poorer biomechanical properties than other fixation methods. Cite this article as: Kılıç F, Polat A, Yamak F, Bozdag E, Fidan F, Başar H. Biomechanical comparison of fixation methods on 3rd generation femoral composite bone models in pauwels type 3 femoral neck fractures: Contribution of the medial buttress plate to fixation. Acta Orthop Traumatol Turc., 2023;57(5):243-249.

1 June 2021 in Hand Surgery and Rehabilitation
Verified
Journal Article
Closed access
MGM. Gürler
M. Gürler
TAT. Aksan
T. Aksan
MÖM.B. Özturk
M.B. Özturk
MTM. Tezcan
M. Tezcan
AYA.N. Toksöz Yıldırım
A.N. Toksöz Yıldırım
FYF. Yamak
F. Yamak

1 May 2022 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
OAOrkhan Aliyev
Orkhan Aliyev
TETunay Erden
Tunay Erden
KSKerim Sarıyılmaz
Kerim Sarıyılmaz
EBErgün Bozdağ
Ergün Bozdağ
ESEmin Sünbüloğlu
Emin Sünbüloğlu
ITİbRahim Tuncay
İbRahim Tuncay
Objective: This study aimed to investigate biomechanically the effects of onlay fibula grafts on Vancouver Type B1 Periprosthetic Femoral Fractures (PPFs). Methods: Vancouver Type B1 PFF models were created in 25 fourth-generation synthetic femurs and fixed with locking plates using bicortical, unicortical screws, and cables. While no graft was used in group 1, onlay fibula grafts were placed anteriorly in group 2 and medially in group 3. In group 4, the cortical strut allograft was placed on the medial femoral cortex, and a locking compression plate (LCP) was applied to the lateral femoral cortex. In group 5, the strut allograft was placed over the anterior cortex of the femur and fixed with the same technique as in group 4. All models were then subjected to rotational and axial cyclical stiffness tests and load to failure to measure and compare the mechanical strengths of the constructs. Results: The mean stiffness values of group 4 with medial allograft, before and after cyclical loading, were higher than all other groups, under both rotational and axial forces. The mean stiffness values of fibula autografts (groups 2 and 3) were similar to that of anterior allografts (group 5) in each test except that the mean initial axial stiffness of group 5 was higher than group 2. Failure loads were also not different between the groups. Conclusion: Although the rigidity of Vancouver type B1 periprosthetic femur fractures is highest if allografts are placed medially, fibula autografts can also provide similar fixation strengths to allografts if locking plates with unicortical and bicortical screws and cables are used. Cite this article as: Aliyev O, Erden T, Sarıyılmaz K, et al. The effect of onlay cortical fibula strut grafts on biomechanical features of vancouver type B1 periprosthetic femoral fractures. Acta Orthop Traumatol Turc. 2022;56(3):166-172.

12 June 2026 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
HKHamit Çağlayan Kahraman
Hamit Çağlayan Kahraman
MDMehmet Demirel
Mehmet Demirel
CYCem Yıldırım
Cem Yıldırım
RKReşit Karaköse
Reşit Karaköse
SGSude Gücük
Sude Gücük
YKYavuz Kocabey
Yavuz Kocabey
In all-inside anterior cruciate ligament (ACL) reconstruction, grafts with free tendon ends require bilateral suturing to suspensory fixation devices durin