Lieve Morbée

Lieve Morbée

Auto-generated profile, based on publicly available information

Lieve Morbée

Department of Radiology Ghent University Hospital Ghent Belgium

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in European Journal of Radiology
Verified
Journal Article
Closed access
LMLieve Morbée
Lieve Morbée
MCMin Chen
Min Chen
NHNele Herregods
Nele Herregods
PPPim Pullens
Pim Pullens
LJLennart B.O. Jans
Lennart B.O. Jans

23 January 2022 in European Radiology
Verified
Journal Article
Open access
PDF file
LMLieve Morbée
Lieve Morbée
MCMin Chen
Min Chen
TBThomas Van Den Berghe
Thomas Van Den Berghe
ESEva Schiettecatte
Eva Schiettecatte
RGRobert Gosselin
Robert Gosselin
LJLennart B. O. Jans
Lennart B. O. Jans
Objectives MRI is the gold standard for soft tissue evaluation in the hip joint. However, CT is superior to MRI in providing clear visualization of bony morphology. The aim of this study is to test the equivalency of MRI-based synthetic CT to conventional CT in quantitatively assessing bony morphology of the hip. Materials and methods A prospective study was performed. Adult patients who underwent MRI and CT of the hips were included. Synthetic CT images were generated from MRI using a deep learning–based image synthesis method. Two readers independently performed clinically relevant measurements for hip morphology, including anterior and posterior acetabular sector angle, acetabular version angle, joint space width, lateral center–edge angle, sharp angle, alpha angle, and femoral head-neck offset on synthetic CT and CT. Inter-method, inter-reader, and intra-reader reliability and agreement were assessed using calculations of intraclass correlation coefficient, standard error of measurement, and smallest detectable change. The equivalency among CT and synthetic CT was evaluated using equivalency statistical testing. Results Fifty-four hips from twenty-seven participants were included. There was no reported hip pathology in the subjects. The observed agreement based on reliability and agreement parameters indicated a strong degree of concordance between CT and synthetic CT. Equivalence statistical testing showed that all synthetic CT measurements are equivalent to the CT measurements at the considered margins. Conclusion In healthy individuals, we demonstrated equivalency of MRI-based synthetic CT to conventional CT for the quantitative evaluation of osseous hip morphology, thus obviating the radiation exposure of a pelvic CT examination. Key Points •MRI-based synthetic CT images can be generated from MRI using a deep learning–based image synthesis method. •MRI-based synthetic CT is equivalent to CT in the quantitative assessment of bony hip morphology in healthy individuals. •MRI-based synthetic CT is promising for use in preoperative diagnosis and surgery planning.

14 December 2022 in European Journal of Radiology
Verified
Journal Article
Closed access
LMLieve Morbée
Lieve Morbée
EVElke Vereecke
Elke Vereecke
FLFrederiek Laloo
Frederiek Laloo
MCMin Chen
Min Chen
NHNele Herregods
Nele Herregods
LJLennart B.O. Jans
Lennart B.O. Jans

12 December 2024 in Diagnostic and Interventional Imaging
Verified
Journal Article
Open access
PTPedro Augusto Gondim Teixeira
Pedro Augusto Gondim Teixeira
HKHippolyte Kessler
Hippolyte Kessler
LMLieve Morbée
Lieve Morbée
NDNicolas Douis
Nicolas Douis
FBFatma Boubaker
Fatma Boubaker
ABAlain Blum
Alain Blum
Magnetic resonance imaging (MRI) techniques that enhance the visualization of mineralized tissues (hereafter referred to as MT-MRI) are increasingly being incorporated into clinical practice, particularly in musculoskeletal imaging. These techniques aim to mimic the contrast provided by computed tomography (CT), while taking advantage of MRI's superior soft tissue contrast and lack of ionizing radiation. However, the variety of MT-MRI techniques, including three-dimensional gradient-echo, ultra-short and zero-echo time, susceptibility-weighted imaging, and artificial intelligence-generated synthetic CT, each offer different technical characteristics, advantages, and limitations. Understanding these differences is critical to optimizing clinical application. This review provides a comprehensive overview of the most commonly used MT-MRI techniques, categorizing them based on their technical principles and clinical utility. The advantages and disadvantages of each approach, including their performance in bone morphology assessment, fracture detection, arthropathy-related findings, and soft tissue calcification evaluation are discussed. Additionally, technical limitations and artifacts that may affect image quality and diagnostic accuracy, such as susceptibility effects, signal-to-noise ratio issues, and motion artifacts are addressed. Despite promising developments, MT-MRI remains inferior to conventional CT for evaluating subtle bone abnormalities and soft tissue calcification due to spatial resolution limitations. However, advances in deep learning and hardware innovations, such as artificial intelligence-generated synthetic CT and ultrahigh-field MRI, may bridge this gap in the future.

Verified
Journal Article
Open access
LMLieve Morbee
Lieve Morbee
EVElke Vereecke
Elke Vereecke
FLFrederiek Laloo
Frederiek Laloo
MCMin Chen
Min Chen
NHNele Herregods
Nele Herregods
LJLennart Jans
Lennart Jans
This review presents an overview of the spectrum of the current and cutting-edge MRI techniques for pelvic bone imaging in clinical practice. The current MRI sequences and their advantages, disadvantages and usefullness in the imaging of this complex anatomical region are addressed. Finally, cutting-edge techniques are discussed, including susceptibility weighted MRI, ultrashort echo time MRI, zero echo time MRI and a deep learning-based multiparametric MRI technique named `synthetic CT,' creating CT-like images without ionizing radiaton.

25 January 2022 in Investigative Radiology
Verified
Journal Article
Open access
TGTim Msc Gossye
Tim Msc Gossye
DBDimitri Msc Buytaert
Dimitri Msc Buytaert
PSPeter V. Smeets
Peter V. Smeets
LMLieve Morbée
Lieve Morbée
EVElke Vereecke
Elke Vereecke
KBKlaus Bacher Klaus Bacher
Klaus Bacher Klaus Bacher
Objectives: Bedside radiographs are usually obtained gridless, without a physical scatter correction grid because of several limitations. Therefore, multiple manufacturers of mobile radiography systems provide the possibility to apply scatter correction software (SC SW) on those images. The purpose of this study was to characterize different series of radiographs—gridless, SC SW, and physical grid—with an image quality assessment algorithm (IQAA). Furthermore, we investigated the potential dose reduction and the correlation between the output of the IQAA and the human observers. Materials and Methods: We obtained different series of radiographs with an anthropomorphic phantom (multipurpose chest phantom N1 “Lungman,” Kyoto Kagaku, Kyoto, Japan). All radiographs were obtained with flat-panel detectors of 5 different manufacturers in a wall bucky system. An IQAA to analyze the radiographs was implemented in our department but was originally developed by the research group of the Duke University Medical Center. Seven physical quantities were calculated by the IQAA: rib-lung contrast (RLcontrast ), subdiaphragm-lung contrast (SLcontrast ), lung detail (Ldetail ), mediastinum detail (Mdetail ), lung noise (Lnoise ), mediastinum noise (Mnoise ), and rib-lung sharpness (RLsharpness ). In a proof of concept, the results of the IQAA were validated by 3 experienced radiologists. Results: Regression coefficients (b) of the linear regression model indicate that the human observer results correlate well with the IQAA (b ≥ 0.89, R 2 ≥ 0.83). All manufacturers have SC SW that increases the 7 physical quantities of the gridless images. However, several manufacturers have SC SW that increases the physical metrics to the same level as the physical grid images. The SC SW radiographs obtained with a reduced tube load have an increased level of contrast, detail, sharpness, and noise compared with the gridless images obtained with the higher tube load. Conclusions: We have proven in a proof of concept that the originally developed IQAA can be used to characterize different series of images of different manufacturers. Based on the physical quantities, SC SW increases the contrast, detail, sharpness, and noise. The experimental results in this study assume a patient dose reduction could be possible when SC SW is applied.