Dimitri Buytaert

Dimitri Buytaert

Auto-generated profile, based on publicly available information

Dimitri Buytaert

Department of Human Structure and Repair, Ghent University, Ghent, Belgium

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DBDimitri Buytaert
Dimitri Buytaert
KVKristof Vandekerckhove
Kristof Vandekerckhove
JPJoseph Panzer
Joseph Panzer
LRLukas Rubbens
Lukas Rubbens
Daniël De WolfDaniël De Wolf
Daniël De Wolf
KBKlaus Bacher
Klaus Bacher
Cardiac catheterization procedures result in high radiation doses and often multiple procedures are necessary for congenital heart disease patients. However, diagnostic reference levels (DRL) remain scarce. Our first goal was finding the optimal DRL parameter and determining appropriate DRLs. The second goal was to calculate organ doses (OD), effective doses (ED) and lifetime attributable risks (LAR) per procedure and to provide conversion factors based on dose area product (DAP). DRLs are calculated for each procedure type, as the 75th percentile of the cumulative value per procedure from the corresponding parameter. All irradiation events in the DICOM Structured Reports were automatically processed and simulated using PCXMC, resulting in OD, ED and LAR. Using a Kruskal Wallis H test and subsequent pairwise comparisons, differences in median values of the DRL parameter between procedure types were assessed. Linear regression showed a strong correlation and narrow confidence interval between DAP and product of body weight and fluoroscopy time (BWxFT), even when all procedures (diagnostic and interventional) are combined. Only 15% of the pairwise comparisons were statistically significant for DAP normalized to BWxFT (DAPBWxFT). The latter pairs contained less frequent procedure types with significant outliers. For DAP normalized to BW (DAPBW), 38% of the pairwise comparisons showed statistically significant differences. Conversion factors from DAPBW to OD and ED were reported for various weight groups, due to the higher correlation between DAPBW and both OD and ED than between DAP and both OD and ED. The P75 of DAPBWxFT for all procedures combined serves as an appropriate DRL value. This facilitates local DRL determination in smaller paediatric centres, which often have insufficient data to produce appropriate DRLs for different procedure types. Conversion factors are more reliable starting from DAPBW instead of DAP and should be used according to the appropriate BW group.

16 February 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
DFDavide Fabbricatore
Davide Fabbricatore
DBDimitri Buytaert
Dimitri Buytaert
CVChiara Valeriano
Chiara Valeriano
NMNiya Mileva
Niya Mileva
Pasquale PaolissoPasquale Paolisso
Pasquale Paolisso
TPTom De Potter
Tom De Potter
The leading reason for delayed discharge after pulmonary vein isolation (PVI) is vascular complications. This study aimed to evaluate feasibility, safety, and efficacy of the Perclose Proglide™ suture-mediated vascular closure in ambulatory PVI, report complications, patient satisfaction, and cost of this approach. Patients scheduled for PVI were enrolled prospectively in an observational design. Feasibility was assessed as % discharged the day of procedure. Efficacy was analysed as acute access site closure rate, time to reach haemostasis, time to ambulate, and time to discharge. Safety analysis consisted of vascular complications at 30 days. Cost analysis was reported using direct and indirect cost analysis. A 1:1 propensity matched control cohort was used for comparing time to discharge to usual workflow. Of 50 enrolled patients, 96% were discharged on the same day. 100% of devices were successfully deployed. Immediate (<1 min) haemostasis was reached in 30 patients (62.5%). Mean time to discharge was 5:48 ± 1:03 h (vs. 10:16 ± 1:21 h in the matched cohort, P < 0.0001). Patients reported high level of satisfaction with the post-operative time. No major vascular complication occurred. Cost analysis showed a neutral impact compared to the standard of care. The use of the closure device for femoral venous access after PVI led to safe discharge of patients within 6 h from the intervention in 96% of the population. This approach could minimize the overcrowding of healthcare facilities. The gain in post-operative recovery time improved patients’ satisfaction and balanced the economic cost of the device.

30 August 2018 in Journal of Interventional Cardiology
Verified
Journal Article
Closed access
PDF file
DBDimitri Buytaert
Dimitri Buytaert
LELiesbeth Eloot
Liesbeth Eloot
MMMaria Mauti
Maria Mauti
BDBenny Drieghe
Benny Drieghe
PGPeter Gheeraert
Peter Gheeraert
KBKlaus Bacher
Klaus Bacher

7 July 2020 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
DBDimitri Buytaert
Dimitri Buytaert
BDBenny Drieghe
Benny Drieghe
FHFrédéric Van Heuverswyn
Frédéric Van Heuverswyn
JPJan De Pooter
Jan De Pooter
PGPeter Gheeraert
Peter Gheeraert
KBKlaus Bacher
Klaus Bacher
Background: Dual axis rotational coronary angiography ( DARCA ) reduces radiation exposure during coronary angiography on older x‐ray systems. The purpose of the current study is to quantify patient and staff radiation exposure using DARCA on a modality already equipped with dose‐reducing technology. Additionally, we assessed applicability of 1 dose area product to effective dose conversion factor for both DARCA and conventional coronary angiography ( CCA ) procedures. Methods and Results: Twenty patients were examined using DARCA and were compared with 20 age‐, sex‐, and body mass index–matched patients selected from a prior study using CCA on the same x‐ray modality. All irradiation events are simulated using PCXMC ( STUK , Finland) to determine organ and effective doses. Moreover, for DARCA each frame is simulated. Staff dose is measured using active personal dosimeters (DoseAware, Philips Healthcare, The Netherlands). With DARCA , median cumulative dose area product is reduced by 57% (ie, 7.41 versus 17.19 Gy·cm 2 ). Effective dose conversion factors of CCA and DARCA are slightly different, yet this difference is not statistically significant. The occupational dose at physician's chest, leg, and collar level are reduced by 60%, 56%, and 16%, respectively, of which the first 2 reached statistical significance. Median effective dose is reduced from 4.75 mSv in CCA to 2.22 mSv in DARCA procedures, where the latter is further reduced to 1.79 mSv when excluding ventriculography. Conclusions: During invasive coronary angiography, DARCA reduces radiation exposure even further toward low‐dose values on a system already equipped with advanced image processing and noise reduction algorithms. For both DARCA and CCA procedures, using 1 effective dose conversion factor of 0.30 mSv·Gy −1 ·cm −2 is feasible.

23 November 2023 in Interventional Cardiology: Reviews, Research, Resources
Verified
Journal Article
Open access
PDF file
HOHirofumi Ohashi
Hirofumi Ohashi
FBFrederic Bouisset
Frederic Bouisset
DBDimitri Buytaert
Dimitri Buytaert
RSRuiko Seki
Ruiko Seki
JSjeroen sonck
jeroen sonck
CCCarlos Collet
Carlos Collet
The role of coronary CT angiography for the diagnosis and risk stratification of coronary artery disease is well established. However, its potential beyond the diagnostic phase remains to be determined. The current review focuses on the insights that coronary CT angiography can provide when planning and performing percutaneous coronary interventions. We describe a novel approach incorporating anatomical and functional pre-procedural planning enhanced by artificial intelligence, computational physiology and online 3D CT guidance for percutaneous coronary interventions. This strategy allows the individualisation of patient selection, optimisation of the revascularisation strategy and effective use of resources.

1 July 2021 in International Journal of Cardiology
Verified
Journal Article
Closed access
MRMaurizio Lodi Rizzini
Maurizio Lodi Rizzini
SNSakura Nagumo
Sakura Nagumo
Diego GalloDiego Gallo
Diego Gallo
JSjeroen sonck
jeroen sonck
TMTakuya Mizukami
Takuya Mizukami
CCCarlos Collet
Carlos Collet