Majd Mzeihem

Majd Mzeihem

Auto-generated profile, based on publicly available information

Majd Mzeihem

Department of Orthopaedic Surgery, University of Illinois at Chicago, Chicago, Illinois

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2025 in EFORT Open Reviews
Verified
Journal Article
Open access
MMMajd Mzeihem
Majd Mzeihem
MNMohamad Nassereddine
Mohamad Nassereddine
AZAnas El Zouhbi
Anas El Zouhbi
FAFarid Amirouche
Farid Amirouche
BEBassem Elhassan
Bassem Elhassan
Rotator cuff tears are prevalent, affecting 20% of the general population, with massive tears accounting for 40% of these cases. Massive tears, those larger than 5 cm or involving several tendons, pose substantial clinical problems, including poorer surgical outcomes and increased recurrence rates. Multiple classification systems offer varied definitions, complicating treatment strategies. The irreparability of these tears, exacerbated by conditions such as tendon atrophy and advanced imaging abnormalities, can further complicate management. Surgical options include superior capsular reconstruction (SCR) and tendon transfers. SCR, which involves attaching a graft to the superior glenoid and greater tuberosity, has shown promise in individuals with intact subscapularis tendons and minimal arthritis. Graft alternatives include fascia lata (FL) autografts, human dermal allografts, and long head of the biceps tendon (LHBT) autografts. Each graft type has distinct advantages and disadvantages, with FL autografts providing greater results despite donor site morbidity. Tendon transfers, such as latissimus dorsi and lower trapezius transfers, offer alternative treatments, especially for younger, more active individuals. This review thoroughly reviews different therapeutic options, emphasizing the most recent evidence and clinical outcomes to help guide the best management of massive posterosuperior irreparable rotator cuff injuries.

19 December 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MMMajd Mzeihem
Majd Mzeihem
LZLuke Zabawa
Luke Zabawa
YPYeseop Park
Yeseop Park
ACAlexander Crespo
Alexander Crespo
YRYazdan Raji
Yazdan Raji
FAFarid Amirouche
Farid Amirouche
Background: Articular depression, especially in central tibial plateau segments, is surgically challenging. According to the 10-segment classification, the anterolateral approach visualizes only 36.6% of the tibial plateau. The aim of this study was to compare biomechanical performance between fluoroscopy-guided fixation techniques with and without needle arthroscopy. Methods: This cadaveric study used 16 knee specimens with standardized lateral tibial plateau fractures. Specimens were randomized to fluoroscopy-guided (FG) or fluoroscopy plus needle arthroscopy-guided (FNG) reduction performed via an anterolateral approach. Kirschner wires and proximal tibial plates were used for fixation. The primary outcome was load to failure. Secondary outcomes included stress, strain, stiffness, reduction quality, radiation exposure, and operative time. Results: Sixteen cadaveric specimens (9 right knees; 12 males) were studied. The FG group had greater mean articular depression (1.77 versus 1.69 mm) and step-off (2.44 versus 2.26 mm) than the FNG group. The FNG group had a higher mean load to failure (1,784 versus 1,063 N), whereas the FG group had greater mean stiffness (170.34 versus 130.82 N/mm) and a longer mean operative time (1,662 versus 1,524 seconds). The FG group also demonstrated higher mean fluoroscopic doses and larger differences in condylar width and the medial tibial plateau angle than the FNG group. Conclusions: FNG reduction improved articular congruity and load to failure in lateral tibial plateau fractures without increasing operative time, supporting needle arthroscopy as a valuable adjunct for managing complex articular fractures with less invasive exposure. Clinical Relevance: This study is clinically relevant because it shows that incorporating needle arthroscopy during fixation of lateral tibial plateau fractures can improve reduction quality and stability without prolonging operative time.

1 July 2025 in JBJS Open Access
Verified
Journal Article
Open access
FAFarid Amirouche
Farid Amirouche
MMMajd Mzeihem
Majd Mzeihem
JHJasper Dean Hoag
Jasper Dean Hoag
RWRohan Wangikar
Rohan Wangikar
JKJason Koh
Jason Koh
Background: Understanding patellofemoral contact pressure is crucial for knee biomechanics, as abnormalities can lead to joint issues. This study investigates the changes in contact pressure after surgical fixation of patellar fractures. Methods: Finite element model of the knee was created using cadaveric data on transverse patellar fractures. Models were analyzed and evaluated at 0°, 45°, and 90° flexion under quadriceps force to assess peak pressure, contact pattern, and pressure irregularity. Results: The plate and wire fixation models exhibited distinct stress distribution patterns at 45° and 90° flexion angles. At 45°, the plate model had a higher peak stress (6.14 MPa) in a 21.0-mm ovular contact area, while the wire model had lower peak stress (2.42 MPa) in a smaller, more fragmented region. At 90°, the plate model exhibited concentrated stress (13.26 MPa) in a heart-shaped area, whereas the wire model had 3 dispersed stress points (9.88 MPa) over a broader surface. These findings highlight the plate model's greater stress concentration and the wire model’s more irregular distribution of stress. At 0°, the plate model exhibited minimal contact pressure compared with the wire model, with a pressure of 6.67 MPa. Conclusion: The plate model better preserves patellofemoral biomechanics, potentially reducing complications and improving long-term outcomes. Further research is needed to confirm its superiority as a fixation method. Clinical Relevance: Although the prevalence of patellar fractures remains high, the gold-standard method for surgical fixation has a postoperative complication rate as high as 52.5%. Addressing the lack of understanding surrounding patellofemoral contact pressure in this scenario is an essential step toward improving outcomes for these patients.

10 October 2025 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
MMMajd Mzeihem
Majd Mzeihem
JKJoseph A. Karam
Joseph A. Karam
JHJibreel Hussain
Jibreel Hussain
JKJason Koh
Jason Koh
FAFarid Amirouche
Farid Amirouche
Introduction: The global incidence of hip fractures continues to rise with an aging population. In the USA, orthopedic residency programs prioritize surgical mentorship to prepare trainees for independent practice. However, the impact of resident involvement on patient outcomes, particularly complications following hip fracture fixation, remains unclear. This study evaluates whether resident participation in intertrochanteric and femoral neck fracture surgical treatments only influences postoperative complication rates. Materials and Methods: We retrospectively analyzed de-identified data from the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) from 2005 to 2012. A total of 6300 patients who underwent hip fracture fixation were identified using ICD-9-CM codes, after excluding incomplete cases. Patients were divided into two cohorts: procedures performed by attending surgeons alone (AA) and those with resident involvement (AR). Groups were matched using propensity score analysis. Postoperative complications were compared using multivariate logistic regression, adjusting for potential confounders. Results: In the AR group, 45.0% of patients experienced at least one complication, compared to 29.3% in the AA group. The AR group had higher rates of postoperative transfusions and systemic complications, including sepsis. Wound dehiscence and organ space infections were significantly more common in the AR group ( P < 0.02). Additionally, the AR group demonstrated longer operation times, extended anesthesia-to-incision intervals, and prolonged hospital stays. When stratified by fracture type, intertrochanteric fractures were associated with significantly higher complication rates compared to femoral neck fractures in the AR group ( P < 0.001). Despite these findings, multivariate regression analysis revealed no significant difference in the rate of serious complications; including cardiopulmonary, neurologic, infectious, renal, and mortality events; between groups. Conclusion: Resident involvement in hip fracture fixation is associated with increased overall complication rates, particularly in intertrochanteric fractures, but does not significantly affect the incidence of serious complications. These findings highlight opportunities to improve resident training, particularly in surgical efficiency, patient positioning, hemostasis, closure technique, and perioperative care, to better prepare residents for independent surgical practice.

31 July 2026 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
MMMajd Mzeihem
Majd Mzeihem
ARAli Rteil
Ali Rteil
YFYasser Farid
Yasser Farid
OMOmar Martini
Omar Martini
HPHristo Piponov
Hristo Piponov
FAFarid Amirouche
Farid Amirouche
Introduction: As robotic-assisted total knee arthroplasty (TKA) gains traction in revision procedures, the urgent need to investigate its effectiveness compared with manual methods becomes apparent. Methods: Data were retrospectively obtained from the TriNetX Collaborative Network. Revision TKA (rKA) cases were identified using CPT codes and categorized as manual or robotic assisted using ICD-10 procedure codes. Cohorts were balanced with 1:1 propensity score matching for demographics, comorbidities, and revision history. Complication rates were compared across follow-up using chi-square analysis. Results: An initial query identified 19,088 manual and 2,709 robotic-assisted rKA cases. After 1:1 propensity matching, 2,010 patients remained in each group. Robotic rKA had significantly lower mechanical implant‑related complications at 3 and 6 months (OR 1.67 and 1.66; P < 0.001) and lower early VTE, while PJI, readmission, and revision rates were not significantly different. Manual rKA showed higher opioid use at 0 to 3 months (OR 1.40, 95% CI, 1.14 to 1.71, P < 0.001) and 3 to 6 months (OR 1.28, 95% CI, 1.12 to 1.47, P < 0.001) and throughout the 3 years of follow-up.Throughout the follow-up period, patellar dislocation, wound infection, non‑implant-related complications, and transfusion did not differ. At 1 year, manual rKA had higher instability (OR 1.59; P = 0.001) and higher hazard of mechanical implant‑related complications (HR 1.52, 95% CI, 1.32 to 1.75; P = 0.049). Instability, loosening, and periprosthetic fracture remained higher at 2 to 3 years, and revision was significantly more frequent at 3 years (13.5% vs. 11.4%; OR 1.22, 95% CI, 1.02 to 1.46; P = 0.03). Discussion: Robotic-assisted rKA was associated with markedly lower mechanical implant‑related complications across early and midterm follow-up, including reduced rates of instability, aseptic loosening, periprosthetic fracture, VTE, and lower opioid requirements. Rates of PJI, readmission, and revision were largely comparable, although manual rKA demonstrated a markedly higher revision rate by 3 years. These findings suggest that robotic assistance may improve implant reliability and postoperative recovery, but prospective studies and cost-effectiveness analyses remain necessary.

13 August 2026 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
ARAli Rteil
Ali Rteil
MMMajd Mzeihem
Majd Mzeihem
MKMarcelline Kemmy
Marcelline Kemmy
HPHristo Piponov
Hristo Piponov
LPLalit Puri
Lalit Puri
FAFarid Amirouche
Farid Amirouche
Background: Patients with spinopelvic risk factors such as lumbar fusion or stiff spine exhibit a 5- to 10-fold increased risk of dislocation following total hip arthroplasty (THA), primarily due to altered spinopelvic mechanics that influence cup positioning. The utilization of robotic-assisted THA facilitates personalized planning, enhancing component placement in this high-risk population. This study aims to compare rates of implant-related and medical complications between robotic-assisted and manual THA in these high-risk patients. Methods: Data were retrospectively obtained from the TriNetX Research Network. Patients with prior lumbar fusion or spinal conditions associated with stiffness or malalignment, and who subsequently underwent THA, were identified using ICD-10 and CPT codes. Procedure codes defined robotic-assisted and manual THA. After 1:1 propensity score matching for age, sex, body mass index, smoking status, and other comorbidities, outcomes were compared at 3, 6, 12 months and 2 years. A subgroup analysis compared both groups in spinal fusion (SF) and nonfusion (no-SF/stiff spine) patients. Results: After 1:1 propensity score matching, each cohort included 2,147 patients. At 3 months, robotic THA was associated with lower prosthetic complications (1.4 vs 2.7%; odds ratio [OR]: 1.86, 95%; P = 0.01) and postoperative blood transfusion (0.9 vs. 1.8%; OR: 2.02, P = 0.01). At 1 year, dislocation was reduced (0.9 vs. 1.8%; OR: 2.07; P = 0.01). Revisions were also lower at 1 and 2-year follow-up in the robotic group (1.7 vs. 2.7%, OR: 1.61; 2.0 vs 3.7%, OR: 1.86; all P < 0.05; respectively), and the manual group had 1.9 times the hazard of having revision surgery at 2 years (HR: 1.9, 95%; P = 0.02). In no-SF patients, robotic THA was associated with markedly lower rates of prosthetic complications and revision surgery. Conclusion: Robotic-assisted THA was associated with fewer complications than manual THA in patients with lumbar fusion or clinically relevant spinal stiffness, a population at elevated risk for instability after THA. Precision-based implant positioning may improve outcomes in patients with altered spinopelvic mobility, including those without spinal fusion.