Christian Osterkamp

Christian Osterkamp

Auto-generated profile, based on publicly available information

Christian Osterkamp

Diatope GmbH

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
COChristian Osterkamp
Christian Osterkamp
MMMartin Mangold
Martin Mangold
JLJohannes Lang
Johannes Lang
PBPriyadharshini Balasubramanian
Priyadharshini Balasubramanian
TTTokuyuki Teraji
Tokuyuki Teraji
FJFedor Jelezko
Fedor Jelezko
Here we report a method for improving the magnetic field sensitivity of an ensemble of Nitrogen-Vacancy (NV) centres in 12C-enriched diamond aligned along the [111] crystal axis. The preferentially-aligned NV centres are fabricated by a Plasma Enhanced Chemical Vapour Deposition (PECVD) process and their concentration is quantitatively determined by analysing the confocal microscopy images. We further observe that annealing the samples at high temperature (1500 °C) in vacuum leads to a conversion of substitutional nitrogen into NV centres. This treatment also increases the coherence time of the NV centres electron spins up to 40 μs, which corresponds to enhancement of the sensitivity by a factor of three. However, this procedure also leads to a loss of the preferential alignment by 34%.

27 June 2022 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
JWJames L. Webb
James L. Webb
LTLuca Troise
Luca Troise
NHNikolaj W. Hansen
Nikolaj W. Hansen
LFLouise F. Frellsen
Louise F. Frellsen
COChristian Osterkamp
Christian Osterkamp
Ulrik L.  AndersenUlrik L. Andersen
Ulrik L. Andersen
The ability to measure the passage of electrical current with high spatial and temporal resolution is vital for applications ranging from inspection of microscopic electronic circuits to biosensing. The ability to image such signals passively and remotely is of great importance, in order to measure without invasive disruption of the system under study or the signal itself. A recent approach to achieving this utilizes point defects in solid-state materials; in particular, nitrogen-vacancy centers in diamond. Acting as a high-density array of independent sensors, addressable opto-electronically and highly sensitive to factors including temperature and magnetic field, these are ideally suited to microscopic wide-field imaging. In this work, we demonstrate simultaneous spatially and temporally resolved recovery signals from a microscopic lithographically patterned circuit. Through application of a lock-in amplifier camera, we demonstrate micrometer-scale imaging resolution with a millimeter-scale field of view with simultaneous spatially resolved submillisecond (up to 3500 frames s−1) recovery of dc to kilohertz alternating and broadband pulsed-current electrical signals, without aliasing or undersampling. We demonstrate as examples of our method the recovery of synthetic signals replicating digital pulses in integrated circuits and signals that would be observed in a biological neuronal network in the brain.

5 April 2022 in Carbon
Verified
Journal Article
Closed access
PBPriyadharshini Balasubramanian
Priyadharshini Balasubramanian
COChristian Osterkamp
Christian Osterkamp
OBOvidiu Brinza
Ovidiu Brinza
MRMaxime Rollo
Maxime Rollo
IRIsabelle Robert-Philip
Isabelle Robert-Philip
ATAlexandre Tallaire
Alexandre Tallaire

29 December 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CFChristoph Findler
Christoph Findler
JLJohannes Lang
Johannes Lang
COChristian Osterkamp
Christian Osterkamp
MNMiloš Nesládek
Miloš Nesládek
FJFedor Jelezko
Fedor Jelezko
The negatively charged nitrogen-vacancy ( $$\hbox {NV}^{-}$$ NV - ) center shows excellent spin properties and sensing capabilities on the nanoscale even at room temperature. Shallow implanted $$\hbox {NV}^{-}$$ NV - centers can effectively be protected from surface noise by chemical vapor deposition (CVD) diamond overgrowth, i.e. burying them homogeneously deeper in the crystal. However, the origin of the substantial losses in $$\hbox {NV}^{-}$$ NV - centers after overgrowth remains an open question. Here, we use shallow $$\hbox {NV}^{-}$$ NV - centers to exclude surface etching and identify the passivation reaction of NV to NVH centers during the growth as the most likely reason. Indirect overgrowth featuring low energy (2.5–5 keV) nitrogen ion implantation and CVD diamond growth before the essential annealing step reduces this passivation phenomenon significantly. Furthermore, we find higher nitrogen doses to slow down the NV–NVH conversion kinetics, which gives insight into the sub-surface diffusion of hydrogen in diamond during growth. Finally, nano sensors fabricated by indirect overgrowth combine tremendously enhanced $$T_2$$ T 2 and $$T_2^*$$ T 2 ∗ times with an outstanding degree of depth-confinement which is not possible by implanting with higher energies alone. Our results improve the understanding of CVD diamond overgrowth and pave the way towards reliable and advanced engineering of shallow $$\hbox {NV}^{-}$$ NV - centers for future quantum sensing devices.

28 August 2020 in Advanced Quantum Technologies
Verified
Journal Article
Open access
PDF file
COChristian Osterkamp
Christian Osterkamp
PBPriyadharshini Balasubramanian
Priyadharshini Balasubramanian
GWGerhard Wolff
Gerhard Wolff
TTTokuyuki Teraji
Tokuyuki Teraji
MNMilos Nesladek
Milos Nesladek
FJFedor Jelezko
Fedor Jelezko
Nitrogen‐vacancy (NV) center ensemble in synthetic diamond is a promising and emerging platform for quantum sensing technologies. Realization of such a solid‐state based quantum sensor is widely studied and requires reproducible manufacturing of NV centers with controlled spin properties, including the spin bath environment within the diamond crystal. Here, a non‐invasive method is reported to benchmark NV ensembles regarding their suitability as ultra‐sensitive magnetic field sensors. Imaging and electron spin resonance techniques are presented to determine operating figures and precisely define the optimal material for NV‐driven diamond engineering. The functionality of the methods is manifested on examples of chemical vapor deposition synthesized diamond layers containing preferentially aligned, isotopically controlled 15 NV center ensembles. Quantification of the limiting 15 N P1 spin bath, in an otherwise 12 C enriched environment, and the reduction of its influence by applying dynamical decoupling protocols, complete the suggested set of criteria for the analysis of NV ensemble with potential use as magnetometers.

28 February 2024 in Physical Review Materials
Verified
Journal Article
Open access
PDF file
CFChristoph Findler
Christoph Findler
RBRémi Blinder
Rémi Blinder
KSKarolina Schüle
Karolina Schüle
PBPriyadharshini Balasubramanian
Priyadharshini Balasubramanian
COChristian Osterkamp
Christian Osterkamp
FJFedor Jelezko
Fedor Jelezko
In diamond, nitrogen defects like the substitutional nitrogen defect (Ns) or the nitrogen-vacancy-hydrogen complex (NVH) outnumber the nitrogen-vacancy (NV) defect by at least one order of magnitude creating a dense spin bath. While neutral Ns has an impact on the coherence of the NV spin state, the atomic structure of NVH reminds of a NV center decorated with a hydrogen atom. As a consequence, the formation of NVH centers could compete with that of NV centers possibly lowering the N-to-NV conversion efficiency in diamond grown with hydrogen-plasma-assisted chemical vapor deposition (CVD). Therefore, monitoring and controlling the spin bath is essential to produce and understand engineered diamond material with high NV concentrations for quantum applications. While the incorporation of Ns in diamond has been investigated on the nano- and mesoscale for years, studies concerning the influence of CVD parameters and the crystal orientation on the NVH formation have been restricted to bulk N-doped diamond providing high-enough spin numbers for electron paramagnetic resonance and optical absorption spectroscopy techniques. Here, we investigate submicron-thick (100)-diamond layers with nitrogen contents of (13.8±1.6)ppm and (16.7±3.6)ppm, and exploiting the NV centers in the layers as local nanosensors, we demonstrate the detection of NVH− centers using double electron-electron resonance (DEER). To determine the NVH− densities, we quantitatively fit the hyperfine structure of NVH− and confirm the results with the DEER method usually used for determining Ns0 densities. With our experiments, we access the spin bath composition on the nanoscale and enable a fast feedback loop in CVD recipe optimization with thin diamond layers instead of resource- and time-intensive bulk crystals. Furthermore, the quantification of NVH− plays a very important role for understanding the dynamics of vacancies and the incorporation of hydrogen into CVD diamond optimized for quantum technologies.