10 June 2019 in Applied Physics Letters
Solid state sensors utilizing diamond nitrogen-vacancy (NV) centers are a promising sensing platform that can provide high sensitivity and spatial resolution at high precision. Such sensors have been realized in bulky laboratory-based forms; however, practical applications demand a miniaturized, portable sensor that can function in a wide range of environmental conditions. Here, we demonstrate such a diamond NV magnetic field sensor. The sensor head fits inside a 3D-printed box and exhibits sub-10 nT/ sensitivity over a 125 Hz bandwidth. We achieve efficient fluorescence collection using an optical filter and diode in contact with the diamond, which is cut at the Brewster angle to maximize the coupling of 532 nm pump light. We discuss the potential of this flexible approach to achieve sub-nT/ shot noise limited sensitivity suitable for detection of a wide range of low-level magnetic fields, particularly those from electrical power systems and from biological sources.
28 January 2021 in Scientific Reports
The ability to perform noninvasive and non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50 pT/ $$\sqrt{\text {Hz}}$$ sensitivity, we show the first measurements of magnetic sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these proof of principle measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques. Although as yet uncompetitive with probe electrophysiology in terms of sensitivity, we demonstrate the feasibility of sensing action potentials via magnetic field in mammals using a diamond quantum sensor, as a step towards microscopic imaging of electrical activity in a biological sample using nitrogen vacancy centres in diamond.
19 October 2020 in Frontiers in Physics
Sensing of signals from biological processes, such as action potential propagation in nerves, are essential for clinical diagnosis and basic understanding of physiology. Sensing can be performed electrically by placing sensor probes near or inside a living specimen or dissected tissue using well-established electrophysiology techniques. However, these electrical probe techniques have poor spatial resolution and cannot easily access tissue deep within a living subject, in particular within the brain. An alternative approach is to detect the magnetic field induced by the passage of the electrical signal, giving the equivalent readout without direct electrical contact. Such measurements are performed today using bulky and expensive superconducting sensors with poor spatial resolution. An alternative is to use nitrogen vacancy (NV) centers in diamond that promise biocompatibilty and high sensitivity without cryogenic cooling. In this work we present advances in biomagnetometry using NV centers, demonstrating magnetic field sensitivity of ~100 pT/ in the DC/low frequency range using a setup designed for biological measurements. Biocompatibility of the setup with a living sample (mouse brain slice) is studied and optimized, and we show work toward sensitivity improvements using a pulsed magnetometry scheme. In addition to the bulk magnetometry study, systematic artifacts in NV-ensemble widefield fluorescence imaging are investigated.
5 July 2022 in Physical Review B
Defects in solid-state materials provide an ideal, robust platform for quantum sensing. To deliver maximum sensitivity, a large ensemble of noninteracting defects hosting quantum states with long coherence is required. Control of such an ensemble is challenging due to the spatial variation in both the defect energy levels and in any control field across a macroscopic sample. In this work, we experimentally demonstrate that we can overcome these challenges using Floquet theory and optimal control optimization methods to efficiently and coherently control a large defect ensemble, suitable for sensing. We apply our methods experimentally to a spin ensemble of up to nitrogen-vacancy centers in diamond. By explicitly including the hyperfine interaction to the intrinsic nuclear spin in the optimization, we design shaped microwave control pulses that can outperform conventional () pulses when applied to sensing schemes, with an improvement in the strength of ensemble response of between 11% and 78%. Through simulation of the ensemble dynamics, we shed light on the bandwidth limitations of large-ensemble reinitialization and propose alternative routes for further improvement.
27 June 2022 in Physical Review Applied
The ability to measure the passage of electrical current with high spatial and temporal resolution is vital for applications ranging from inspection of microscopic electronic circuits to biosensing. The ability to image such signals passively and remotely is of great importance, in order to measure without invasive disruption of the system under study or the signal itself. A recent approach to achieving this utilizes point defects in solid-state materials; in particular, nitrogen-vacancy centers in diamond. Acting as a high-density array of independent sensors, addressable opto-electronically and highly sensitive to factors including temperature and magnetic field, these are ideally suited to microscopic wide-field imaging. In this work, we demonstrate simultaneous spatially and temporally resolved recovery signals from a microscopic lithographically patterned circuit. Through application of a lock-in amplifier camera, we demonstrate micrometer-scale imaging resolution with a millimeter-scale field of view with simultaneous spatially resolved submillisecond (up to 3500 frames ) recovery of dc to kilohertz alternating and broadband pulsed-current electrical signals, without aliasing or undersampling. We demonstrate as examples of our method the recovery of synthetic signals replicating digital pulses in integrated circuits and signals that would be observed in a biological neuronal network in the brain.
4 June 2021 in Physical Review A
Nitrogen vacancy (NV) centers in diamond have attracted considerable recent interest for use in quantum sensing, promising increased sensitivity for applications ranging from geophysics to biomedicine. Conventional sensing schemes involve monitoring the change in red fluorescence from the NV center under green laser and microwave illumination. Due to the strong fluorescence background from emission in the NV triplet state and low relative contrast of any change in output, sensitivity is severely restricted by a high optical shot noise level. Here, we propose a means to avoid this issue, by using the change in green pump absorption through the diamond as part of a semiconductor external cavity laser run close to the lasing threshold. We show that theoretical sensitivity to the magnetic field on the pT/ level is possible using a diamond with an optimal density of NV centers. We discuss the physical requirements and limitations of the method, particularly the role of amplified spontaneous emission near threshold and explore realistic implementations using current technology.