Søren Michael Mørk Friis

Søren Michael Mørk Friis

Auto-generated profile, based on publicly available information

Søren Michael Mørk Friis

NLIR Aps, Farum, Denmark

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JCJesper Christensen
Jesper Christensen
LHLasse Høgstedt
Lasse Høgstedt
SFSøren M. M. Friis
Søren M. M. Friis
JLJui-Yu Lai
Jui-Yu Lai
MCMing-Hsien Chou
Ming-Hsien Chou
Mikael LassenMikael Lassen
Mikael Lassen
Quartz-enhanced photoacoustic sensing is a promising method for low-concentration trace-gas monitoring due to the resonant signal enhancement provided by a high-Q quartz tuning fork. However, quartz-enhanced photoacoustic spectroscopy (QEPAS) is associated with a relatively slow acoustic decay, which results in a reduced spectral resolution and signal-to-noise ratio as the wavelength tuning rate is increased. In this work, we investigate the influence of wavelength scan rate on the spectral resolution and signal-to-noise ratio of QEPAS sensors. We demonstrate the acquisition of photoacoustic spectra from 3.1 μm to 3.6 μm using a tunable mid-infrared optical parametric oscillator. The spectra are attained using wavelength scan rates differing by more than two orders of magnitude (from 0.3 nm s−1 to 96 nm s−1). With this variation in scan rate, the spectral resolution is found to change from 2.5 cm−1 to 9 cm−1. The investigated gas samples are methane (in nitrogen) and a gas mixture consisting of methane, water, and ethanol. For the gas mixture, the reduced spectral resolution at fast scan rates significantly complicates the quantification of constituent gas concentrations.

11 April 2026 in Applied Physics B
Verified
Journal Article
Open access
PDF file
LALudovica Appignani
Ludovica Appignani
PTPeter Tidemand-Lichtenberg
Peter Tidemand-Lichtenberg
LHLasse Høgstedt
Lasse Høgstedt
SFSøren Michael Mørk Friis
Søren Michael Mørk Friis
CPChristian Pedersen
Christian Pedersen
2 μm lasers are widely employed in LIDAR systems, photomedicine, and as pump sources for OPOs and mid-IR lasers. Tm:YLF is an optimal laser crystal for a 2 μm laser owing to its good mechanical properties, a negative thermo-optic coefficient, and intrinsic birefringence supporting polarized emission. However, many 2 μm lasers have been reported to exhibit unstable operation with a tendency towards self-pulsation (SP). In this paper, we investigate design parameters influencing the temporal output of a compact diode-laser pumped Tm:YLF 1.91 μm laser for stable continuous-wave (CW) and self-pulsating operation. Different sources of perturbation are discussed as main causes for SP. We introduce a novel pulse attenuation parameter, $$\delta $$ , to assess laser stability. We report optical-to-optical slope efficiencies of 35% and 41.5% in stable CW and SP operation, respectively.