30 October 2025 in Classical and Quantum Gravity
Various noise sources will impact the laser interferometer space antenna (LISA) interferometric measurements, particularly laser frequency noise, which will dominate by several orders of magnitude. To achieve the required sensitivity for gravitational wave detection, noise reduction methods, such as the time-delay interferometry (TDI) algorithm, must be employed and tested using both computer and instrumental simulations. For this purpose, the electro-optical simulator LISA On table has been used to generate realistic LISA signals at the APC laboratory. This experiment also allows the testing of a LISA phasemeter (PM) prototype. In this paper, we experimentally demonstrate the coupling between the TDI algorithm and the PM anti-aliasing filters, which leads to the appearance of aliasing and non-stationary noise at high frequencies. We also propose an analytical model that allows us to estimate the impact of this coupling on our data and to constrain the design of the cascaded integrator-comb filter for a simplified LISA constellation. In addition, we explore the periodicity and impact of this non-stationarity in the case of a simplified LISA-like constellation with linearly evolving arm length.
10 November 2022 in Physical Review D
For broadband quantum noise reduction of gravitational-wave detectors, a frequency-dependent squeezed vacuum field realized using a filter cavity is the most promising technique and will be implemented in Advanced LIGO and Advanced Virgo in the fourth observing run. To obtain the benefit of frequency-dependent squeezing, the length and alignment of the filter cavity with respect to the squeezed vacuum field must be accurately controlled. To this purpose, a new length and alignment control scheme for a filter cavity, using coherent control sidebands, was suggested [ Phys. Rev. D 102, 042003 (2020)]. The coherent control sidebands are already used to control the squeezing angle in squeezed vacuum sources for gravitational-wave detectors. As both the squeezed vacuum field and coherent control sidebands have the same mode-matching conditions and almost the same frequency, the length and alignment of the filter cavity with respect to the squeezed vacuum field can be accurately controlled with this scheme. In this paper, we experimentally demonstrate the new control scheme for a filter cavity with coherent control sidebands. In addition to the conventional filter cavity control with the green field, we succeed in controlling the length of a 300-m filter cavity with coherent control sidebands and reduce the filter cavity length noise (rms) from 6.8 to 2.1 pm.