16 September 2020 in Frontiers in Bioengineering and Biotechnology
Introduction: During cyclical steady state ambulation, such as walking, variability in stride intervals can indicate the state of the system. In order to define locomotor system function, observed variability in motor patterns, stride regulation and gait complexity must be assessed in the presence of a perturbation. Common perturbations, especially for military populations, are load carriage and an imposed locomotion pattern known as forced marching (FM). We examined the interactive effects of load magnitude and locomotion pattern on motor variability, stride regulation and gait complexity during bipedal ambulation in recruit-aged females. Methods: Eleven healthy physically active females (18–30 years) completed 1-min trials of running and FM at three load conditions: no additional weight/bodyweight (BW), an additional 25% of BW (BW + 25%), and an additional 45% of BW (BW + 45%). A goal equivalent manifold (GEM) approach was used to assess motor variability yielding relative variability (RV; ratio of “good” to “bad” variability) and detrended fluctuation analysis (DFA) to determine gait complexity on stride length (SL) and stride time (ST) parameters. DFA was also used on GEM outcomes to calculate stride regulation. Results: There was a main effect of load (p = 0.01) on RV; as load increased, RV decreased. There was a main effect of locomotion (p = 0.01), with FM exhibiting greater RV than running. Strides were regulated more tightly and corrected quicker at BW + 45% compared (p < 0.05) to BW. Stride regulation was greater for FM compared to running. There was a main effect of load for gait complexity (p = 0.002); as load increased gait complexity decreased, likewise FM had less (p = 0.02) gait complexity than running. Discussion: This study is the first to employ a GEM approach and a complexity analysis to gait tasks under load carriage. Reduction in “good” variability as load increases potentially exposes anatomical structures to repetitive site-specific loading. Furthermore, load carriage magnitudes of BW + 45% potentially destabilize the system making individuals less adaptable to additional perturbations. This is further evidenced by the decrease in gait complexity, which all participants demonstrated values similarly observed in neurologically impaired populations during the BW + 45% load condition.
30 August 2022 in Journal of Biomechanics
23 February 2022 in Clinical Orthopaedics and Related Research
Background: Hip microinstability is an increasingly recognized source of pain and dysfunction but has no agreed upon diagnostic criteria and the pathophysiology remains unclear. It has been suggested that pain associated with microinstability is caused by excess translation of the femoral head. Recent research indicates that single-plane femoral head translation can be reliably measured using dynamic ultrasonography during a supine clinical examination; however, the overall accuracy of that technique has not been established, and the range of femoral head translation values that are found in individuals with no history of surgery or symptomatic pathology is unknown. Questions/purposes: (1) How much femoral head translation is present in native, uninjured hips during a weightbearing apprehension position for females and males? (2) How large is the side-to-side difference in hip translation and rotation within the same individual in females and males with no history of surgery or pain during the weightbearing apprehension position? (3) What differences exist in femoral head translation and rotation when comparing females to males? Methods: Twenty-two young adults (11 males, 11 females; mean age 22 ± 2 years; BMI 22 ± 5 kg/m2) with no history of hip pain, no known hip injury, and who never had hip surgery participated in this study. High-resolution CT images of the femur and pelvis were acquired for each participant, and the bone tissue was segmented from the CT volume. Synchronized biplane radiographs were collected during a neutral standing trial and during a static weightbearing apprehension position in which the participant extended, externally rotated, and abducted at their back hip while standing with their feet split in the AP direction. A validated volumetric model-based tracking technique was used to match the patient-specific bone models to the biplane radiographs with an accuracy of 0.3 mm for translation and 0.8° for rotation. Translation of the center of the femoral head relative to the center of the acetabulum and rotation of the femur relative to the pelvis from neutral to the weightbearing apprehension position were calculated. Sex-based differences in hip kinematics were assessed by bivariate linear regression. Results: The median (range) translation during the weightbearing apprehension position in females was 0.9 mm (0.2 to 2.7 mm), which was less than in the 1.3 mm (0.2 to 2.6 mm) translation found in males (median difference of 0.5 mm; p = 0.04). The median absolute side-to-side difference in translation during the pivot was 1.4 mm (0.1 to 3.8 mm) in females and 1.3 mm (0.1 to 4.4 mm) in males. Conclusion: These findings demonstrate that the femoral head translates the same under bodyweight loading as previously observed during supine exam, showing the inherent stability of the hip with no history of surgery or symptomatic pathology. This study also provides normal values for comparison with individuals who have suspected microinstability. Future directions for research include directly comparing biplane radiography to alternative imaging techniques, such as dynamic ultrasound, for identifying hip microinstability and identifying threshold values for symptomatic hip microinstability. Level of Evidence: Level III, prognostic study.
1 July 2021 in Gait & Posture
30 September 2024 in Journal of Biomechanical Engineering
The purpose of this study was to identify side-to-side and sex-based differences in hip kinematics during a unilateral step-up from deep flexion. Twelve (eight men, four women) asymptomatic young adults performed a step ascent motion while synchronized biplane radiographs of the hip were collected at 50 images per second. Femur and pelvis position were determined using a validated volumetric model-based tracking technique that matched digitally reconstructed radiographs created from subject-specific computed tomography (CT) bone models to each pair of synchronized radiographs. Hip kinematics and side-to-side differences were calculated and a linear mixed effects model evaluated sex-based differences. Women were on average 10.2 deg more abducted and 0.2 mm more medially translated than men across the step up motion (p < 0.001). Asymmetry between hips was up to 14.1 ± 12.1 deg in internal rotation and 1.3 ± 1.4 mm in translation. This dataset demonstrates the inherent asymmetry during movements involving unilateral hip extension from deep flexion and may be used provide context for observed kinematics differences following surgery or rehabilitation. Previously reported kinematic differences between total hip arthroplasty and contralateral hips may be well within the natural side-to-side differences that exist in asymptomatic native hips.
21 August 2025 in Annals of Biomedical Engineering