Sana Hannan

Sana Hannan

Auto-generated profile, based on publicly available information

Sana Hannan

Department of Biomedical and Life Sciences Lancaster University Lancaster UK

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2018 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
KAKirill Y Aristovich
Kirill Y Aristovich
MDMatteo Donegá
Matteo Donegá
CBCamille Blochet
Camille Blochet
JAJames Avery
James Avery
SHSana Hannan
Sana Hannan
DHdavid holder
david holder
Understanding the coding of neural activity in nerve fascicles is a high priority in computational neuroscience, electroceutical autonomic nerve stimulation and functional electrical stimulation for treatment of paraplegia. Unfortunately, it has been little studied as no technique has yet been available to permit imaging of neuronal depolarization within fascicles in peripheral nerve. We report a novel method for achieving this, using a flexible cylindrical multi-electrode cuff placed around nerve and the new medical imaging technique of fast neural electrical impedance tomography (EIT). In the rat sciatic nerve, it was possible to distinguish separate fascicles activated in response to direct electrical stimulation of the posterior tibial and common peroneal nerves. Reconstructed EIT images of fascicular activation corresponded with high spatial accuracy to the appropriate fascicles apparent in histology, as well as the inverse source analysis (ISA) of compound action potentials (CAP). With this method, a temporal resolution of 0.3 ms and spatial resolution of less than 100 µm was achieved. The method presented here is a potential solution for imaging activity within peripheral nerves with high spatial accuracy. It also provides a basis for imaging and selective neuromodulation to be incorporated in a single implantable non-penetrating peri-neural device.

1 January 2018 in NeuroImage: Clinical
Verified
Journal Article
Open access
SHSana Hannan
Sana Hannan
MFMayo Faulkner
Mayo Faulkner
KAKirill Aristovich
Kirill Aristovich
JAJames Avery
James Avery
MWMatthew Walker
Matthew Walker
DHdavid holder
david holder
Electrical Impedance Tomography (EIT) is an emerging medical imaging technique which can produce tomographic images of internal impedance changes within an object using non-penetrating surface electrodes. It has previously been used to image impedance changes due to neuronal depolarisation during evoked potentials in the rat somatosensory cortex with a resolution of 2 ms and <200 μm, using an epicortical electrode array. The purpose of this work was to use this technique to elucidate the intracortical spatiotemporal trajectory of ictal spike-and-wave discharges (SWDs), induced by electrical stimulation in an acute rat model of epilepsy, throughout the cerebral cortex. Seizures lasting 16.5 ± 5.3 s with repetitive 2-5 Hz SWDs were induced in five rats anaesthetised with fentanyl-isoflurane. Transfer impedance measurements were obtained during each seizure with a 57-electrode epicortical array by applying 50 μA current at 1.7 kHz to two electrodes and recording voltages from all remaining electrodes. Images were reconstructed from averaged SWD-related impedance traces obtained from EIT measurements in successive seizures. We report the occurrence of reproducible impedance changes during the initial spike phase, which had an early onset in the whisker barrel cortex and spread posteriorly, laterally and ventrally over 20 ms (p < 0.03125, N = 5). These findings, which confirm and extend knowledge of SWD initiation and expression, suggest that EIT is a valuable neuroimaging tool for improving understanding of neural circuits implicated in epileptic phenomena.

1 September 2018 in NeuroImage
Verified
Journal Article
Open access
MFMayo Faulkner
Mayo Faulkner
SHSana Hannan
Sana Hannan
KAKirill Aristovich
Kirill Aristovich
JAJames Avery
James Avery
DHdavid holder
david holder
Electrical Impedance Tomography (EIT) is an emerging technique which has been used to image evoked activity during whisker displacement in the cortex of an anaesthetised rat with a spatiotemporal resolution of 200 μm and 2 ms. The aim of this work was to extend EIT to image not only from the cortex but also from deeper structures active in somatosensory processing, specifically the ventral posterolateral (VPL) nucleus of the thalamus. The direct response in the cortex and VPL following 2 Hz forepaw stimulation were quantified using a 57-channel epicortical electrode array and a 16-channel depth electrode. Impedance changes of -0.16 ± 0.08% at 12.9 ± 1.4 ms and -0.41 ± 0.14% at 8.8±1.9 ms were recorded from the cortex and VPL respectively. For imaging purposes, two 57-channel epicortical electrode arrays were used with one placed on each hemisphere of the rat brain. Despite using parameters optimised toward measuring thalamic activity and undertaking extensive averaging, reconstructed activity was constrained to the cortical somatosensory forepaw region and no significant activity at a depth greater than 1.6 mm below the surface of the cortex could be reconstructed. An evaluation of the depth sensitivity of EIT was investigated in simulations using estimates of the conductivity change and noise levels derived from experiments. These indicate that EIT imaging with epicortical electrodes is limited to activity occurring 2.5 mm below the surface of the cortex. This depth includes the hippocampus and so EIT has the potential to image activity, such as epilepsy, originating from this structure. To image deeper activity, however, alternative methods such as the additional implementation of depth electrodes will be required to gain the necessary depth resolution.

1 April 2020 in NeuroImage
Verified
Journal Article
Open access
SHSana Hannan
Sana Hannan
MFMayo Faulkner
Mayo Faulkner
KAKirill Aristovich
Kirill Aristovich
JAJames Avery
James Avery
MWMatthew C. Walker
Matthew C. Walker
DHdavid holder
david holder
Electrical impedance tomography (EIT) is a medical imaging technique which reconstructs images of the internal impedance changes within an object using non-penetrating surface electrodes. To date, EIT has been used to image fast neural impedance changes during somatosensory evoked potentials and epileptiform discharges through the rat cerebral cortex with a resolution of 2 ​ms and <300 ​μm. However, imaging of neural activity in subcortical structures has never been achieved with this technique. Here, we evaluated the feasibility of using EIT to image epileptiform activity in the rat hippocampus using non-penetrating electrodes implanted on the cortical surface. Hippocampal epileptiform events, comprising repetitive 30-50 ​Hz ictal spikes, were induced by electrically stimulating the perforant path of rats anaesthetised with fentanyl-isoflurane. For each of ≥30 seizures, impedance measurements were obtained by applying 100 ​μA current at 1.4 ​kHz through an independent pair of electrodes on a 54-electrode planar epicortical array and recording boundary voltages on all remaining electrodes. EIT images of averaged ictal spikes were reconstructed using impedance recordings from all seizures in each animal. These revealed a focus of neural activity localised to the dentate gyrus which was spatially and temporally aligned to local field potential (LFP) recordings and could be reconstructed reproducibly in all animals with a localisation accuracy of ≤400 ​μm (p ​< ​0.03125, N ​= ​5). These findings represent the first experimental evidence of the ability of EIT to image neural activity in subcortical structures from the surface of the cortex with high spatiotemporal resolution and suggest that this method may be used for improving understanding of functional connectivity between cortico-hippocampal networks in both physiological and pathophysiological states.

1 January 2021 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
SHSana Hannan
Sana Hannan
KAKirill Y Aristovich
Kirill Y Aristovich
MFMayo Faulkner
Mayo Faulkner
JAJames Avery
James Avery
MWMatthew C Walker
Matthew C Walker
DHdavid holder
david holder
Objective . Electrical impedance tomography (EIT) is an imaging technique that produces tomographic images of internal impedance changes within an object using surface electrodes. It can be used to image the slow increase in cerebral tissue impedance that occurs over seconds during epileptic seizures, which is attributed to cell swelling due to disturbances in ion homeostasis following hypersynchronous neuronal firing and its associated metabolic demands. In this study, we characterised and imaged this slow impedance response during neocortical and hippocampal epileptiform events in the rat brain and evaluated its relationship to the underlying neural activity. Approach. Neocortical or hippocampal seizures, comprising repeatable series of high-amplitude ictal spikes, were induced by electrically stimulating the sensorimotor cortex or perforant path of rats anaesthetised with fentanyl-isoflurane. Transfer impedances were measured during ≥30 consecutive seizures, by applying a sinusoidal current through independent electrode pairs on an epicortical array, and combined to generate an EIT image of slow activity. Main results. The slow impedance responses were consistently time-matched to the end of seizures and EIT images of this activity were reconstructed reproducibly in all animals ( p < 0.03125, N = 5). These displayed foci of activity that were spatially confined to the facial somatosensory cortex and dentate gyrus for neocortical and hippocampal seizures, respectively, and encompassed a larger volume as the seizure progressed. Centre-of-mass analysis of reconstructions revealed that this activity corresponded to the true location of the epileptogenic zone, as determined by EEG recordings and fast neural EIT measurements which were obtained simultaneously. Significance. These findings suggest that the slow impedance response presents a reliable marker of hypersynchronous neuronal activity during epileptic seizures and can thus be utilised for investigating the mechanisms of epileptogenesis in vivo and for aiding localisation of the epileptogenic zone during presurgical evaluation of patients with refractory epilepsies.

16 February 2018 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
MFMayo Faulkner
Mayo Faulkner
SHSana Hannan
Sana Hannan
KAKirill Y Aristovich
Kirill Y Aristovich
JAJames Avery
James Avery
DHdavid holder
david holder
Objective. Electrical Impedance Tomography (EIT) can image impedance changes associated with evoked physiological activity in the cerebral cortex using an array of epicortical electrodes. An impedance change is observed as the externally applied current, normally confined to the extracellular space is admitted into the conducting intracellular space during neuronal depolarisation. The response is largest at DC and decreases at higher frequencies due to capacitative transfer of current across the membrane. Biophysical modelling has shown that this effect becomes significant above 100 Hz. Recordings at DC, however, are contaminated by physiological endogenous evoked potentials. By moving to 1.7 kHz, images of somatosensory evoked responses have been produced down to 2 mm with a resolution of 2 ms and 200 µm. Hardware limitations have so far restricted impedance measurements to frequencies < 2 kHz. The purpose of this work was to establish the optimal frequency for extending EIT to image throughout the brain and to characterise the response at frequencies > 2 kHz using improved hardware. Approach. Impedance changes were recorded during forepaw somatosensory stimulation in both cerebral cortex and the VPL nucleus of the thalamus in anaesthetised rats using applied currents of 1 kHz to 10 kHz. Main results. In the cortex, impedance changed by -0.04 ± 0.02 % at 1 kHz, reached a peak of -0.13 ± 0.05 % at 1475 Hz and decreased to -0.05 ± 0.02 % at 10 kHz. At these frequencies, changes in the thalamus were -0.26 ± 0.1 %, -0.4 ± 0.15 % and -0.08 ± 0.03 % respectively. The signal-to-noise ratio (SNR) was also highest at 1475 Hz with values of 29.5 ± 8 and 31.6 ± 10 recorded from the cortex and thalamus respectively. Significance. This indicates that the optimal frequency for imaging cortical and thalamic evoked activity using fast neural EIT is 1475 Hz.