Mesenchymal stem cells (MSCs) exhibit a potent immunomodulatory capacity and have been applied to treat diseases such as graft versus host disease and severe autoimmune diseases. However, the mechanism underlying their immunosuppressive effect is not yet completely understood. Here, we investigated the role of the CD73/adenosine pathway in immune modulation by MSCs using a mouse model of experimental autoimmune uveitis (EAU). Moreover, we examined the in vitro modulatory effect of MSCs mediated through the CD73/adenosine pathway in human and mouse T cells. We found that the severity of EAU was significantly attenuated by MSCs; however, most therapeutic effects of MSCs were lost by pretreatment with a CD73 inhibitor. The inhibitory mechanism of MSCs might be contributed by CD73 on MSCs that cooperated with CD39 and CD73 on activated T cells to produce adenosine, resulting in inhibition of T-cell proliferation. Furthermore, MSCs increased the expression of CD73 on CD4 + T cells, and transforming growth factor-β1 (TGF-β1) was the only tested cytokine that contributed to upregulation of CD73. Hence, our study demonstrates that the CD73/adenosine pathway involves the immunomodulatory function of MSCs in autoimmune responses.
15 October 2022 in Advances in Ophthalmology Practice and Research
Purpose: To investigate the influence of posterior corneal astigmatism on the prediction accuracy of toric multifocal intraocular lens (IOL) calculation. Methods: The keratometric astigmatism measured by Lenstar LS 900 (KCA(L)), keratometric astigmatism (KCA(P)) and total corneal astigmatism (TCA) measured by Scheimpflug camera (Pentacam HR) were documented and analyzed accordingly. Three deduction models using different parameters were compared. Model 1: KCA(L) + keratometric corneal surgically induced astigmatism (KCSIA, 0.30 D @ 50 degrees); Model 2: KCA(P) + KCSIA); Model 3: TCA + total CSIA (TCSIA, 0.23 D @ 50 degrees). The prediction errors of each model as the difference vector between the actual and the intended residual astigmatism were compared. Results: Seventy-six eyes implanted with toric multifocal IOLs were included in this study. The vector differences of the actual KCSIA and TCSIA were statistically significant in the total sample and against-the-rule (ATR) subgroup (both P < 0.05). Model 1 deduced the smallest mean values of prediction error, while that of Model 3 were smaller than that of Model 2, both in the total sample and the ATR subgroups (all P < 0.05). Meanwhile, in the total sample and ATR subgroups, the centroid vector magnitudes of Model 3 were smaller than that of Model 1 (0.31 +/- 0.76 D and 0.39 +/- 0.76 D). Conclusions: The calculation of toric multifocal IOL should be individualized especially in the ATR eyes for the impact of PCA on the estimation of the preoperative corneal astigmatism and the CSIA.
1 December 2023 in Journal of Cataract & Refractive Surgery
FZFangyu Master'S Degree Zhao
Fangyu Master'S Degree Zhao
+3
Purpose: To evaluate and compare the accuracy of iTrace and CASIA2 in measuring the postoperative orientation of toric intraocular lens (IOL) without mydriasis. Setting: Tianjin Medical University Eye Hospital, Tianjin, China. Design: Prospective cohort study. Methods: Patients with SN6AT toric IOLs implanted after cataract surgery were enrolled. 1 month after surgery, the toric IOL orientation were measured by iTrace and CASIA2 in non-mydriatic, semi-dark conditions. Then, the toric axis was directly reviewed using the slit-lamp under full mydriasis. Axis measurement differences between each of the 2 devices and the slit-lamp, described as their relative differences (RDs), were calculated and compared. The percentage of RDs within 5 degrees, within 10 degrees and greater than 30 degrees were analyzed. Results: 77 eyes of 70 patients were included. Generally, the mean toric axis measurement RDs of CASIA2 and iTrace were 9.24 ± 10.53 degrees and 13.89 ± 15.47 degrees respectively (P = .04). For CASIA2 (72 eyes), 54.17% (39), 72.22% (52), and 4.17% (3) of eyes had RDs within 5 degrees, within 10 degrees and greater than 30 degrees, compared with 40.00% (28), 61.43% (43) and 12.86% (9) for iTrace (70 eyes). The 95% limits of agreements of CASIA2 with slit-lamp was narrower than that of iTrace with slit-lamp. The median RD of CASIA2 was significantly smaller in eyes with pupil ≥4 mm under dark condition compared with eyes with pupil 4 mm.