Zenon Kidoń

Zenon Kidoń

Auto-generated profile, based on publicly available information

Zenon Kidoń

Department of Electronics, Electrical Engineering and Microelectronics, Silesian University of Technology, 44-100 Gliwice, Poland

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in Gait & Posture
Verified
Journal Article
Closed access
MDMałgorzata Domagalska-Szopa
Małgorzata Domagalska-Szopa
ASAndrzej Szopa
Andrzej Szopa
MSMalgorzata Syczewska
Malgorzata Syczewska
SPStanisław Pietraszek
Stanisław Pietraszek
ZKZenon Kidoń
Zenon Kidoń
GOGrzegorz Onik
Grzegorz Onik

1 January 2014 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ASAndrzej Szopa
Andrzej Szopa
MDMałgorzata Domagalska-Szopa
Małgorzata Domagalska-Szopa
ZKZenon Kidoń
Zenon Kidoń
MSMalgorzata Syczewska
Malgorzata Syczewska
Development of a reliable and objective test of spasticity is important for assessment and treatment of children with cerebral palsy. The pendulum test has been reported to yield reliable measurements of spasticity and to be sensitive to variations in spasticity in these children. However, the relationship between the pendulum test scores and other objective measures of spasticity has not been studied. The present study aimed to assess the effectiveness of an accelerometer-based pendulum test as a measurement of spasticity in CP, and to explore the correlation between the measurements of this test and the global index of deviation from normal gait in in children with cerebral palsy.

1 December 2015 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
TŁT. Łukaszewicz
T. Łukaszewicz
Dariusz KaniaDariusz Kania
Dariusz Kania
ZKZ. Kidoń
Z. Kidoń
KPK. Pethe-Kania
K. Pethe-Kania
The article presents a number of posturographic methods enabling objective postural symmetry assessment in patients undergoing rehabilitation after total hip replacement surgery. The key goal of such rehabilitation is fast restoration of a proper body weight distribution. The postural symmetry measures proposed in the article enable generalized quantification of the CoP (Center of Pressure) trajectories measured during standard static posturography diagnostics and the so-called follow-up posturography examination. The follow-up posturography is a relatively new but promising method of physical rehabilitation. All of the herein discussed posturographic measures have been designed specifically to quantify postural symmetry either in a standing and relaxed upright position, in the absence of any deterministic external stimulation (static posturography) or in the presence of a visual biofeedback stimulation enforcing the coordinated slow swaying movements of the body (the follow-up posturography). The experimental results presented in this paper constitute the outcome of the long-term cooperation between the Institute of Electronics of the Silesian University of Technology and the Silesian Rheumatology and Rehabilitation Hospital. The usefulness of the proposed postural symmetry measures has been verified in a series of clinical trials carried out in a selected group of patients undergoing rehabilitation after total hip replacement surgery.

29 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
KKKATARZYNA KNIAZIEW-Gomoluch
KATARZYNA KNIAZIEW-Gomoluch
ASAndrzej Szopa
Andrzej Szopa
ZKZenon Kidoń
Zenon Kidoń
ASAndrzej Siwiec
Andrzej Siwiec
MDMałgorzata Domagalska-Szopa
Małgorzata Domagalska-Szopa
A review of the literature indicated that the greatest prognostic value for predicting motor impairment in high-risk infants is the absence of fidgety movements (FMs) at 3 months of post-term age. The purpose of the present study was to characterize a new posturometric test (PT) based on a center-of-pressure (CoP) movement analysis, in terms of design and construct validity, for the detection of postural control disturbances in pre-term infants. The comparative studies were carried out between pre-term infants who presented normal FMs (18 participants) and infants with absent FMs (19 participants), which consisted of the analysis of the CoP trajectory and CoP area in supine and prone positions using the force platform. New PT was performed simultaneously with GMs recorded using a force platform. Statistical analyses revealed significant differences between the groups of infants who presented absent FMs and normal FMs for almost all CoP parameters describing spontaneous sway in the supine position. Based on these preliminary results, it can be concluded, that the application of PT based on the analysis of CoP trajectory, area, and velocity in the supine position has been demonstrated to be valid for the detection of postural control disturbances in pre-term infants.

1 January 2009 in IFAC Proceedings Volumes
Verified
Journal Article
Closed access
PDF file
AMA. Malcher
A. Malcher
ZKZ. Kidoń
Z. Kidoń

KKKATARZYNA KNIAZIEW-Gomoluch
KATARZYNA KNIAZIEW-Gomoluch
ASAndrzej Szopa
Andrzej Szopa
TŁTomasz Łosień
Tomasz Łosień
JSJan Siwiec
Jan Siwiec
ZKZenon Kidoń
Zenon Kidoń
MDMałgorzata Domagalska-Szopa
Małgorzata Domagalska-Szopa
Background: the current study aims to evaluate the reliability and repeatability of a new PT based on Center of Pressure (CoP) movement analysis in a repeated measures design. Methods: the examination consisted of two parts: (1) the videotaping of General Movements (GMs) and GMs assessment (GMA) and (2) Posturometric Tests (PT) in supine and prone positions. PTs were performed twice (by two investigators) in the supine and prone positions using a force plate. Based on the GMA results, infants were stratified into two groups: (1) infants with normal FMs (indicating normal future motor outcomes) (n = 18) and (2) infants with abnormal FMs (indicating later neurological dysfunction) (n = 19). Results: the comparative analysis between the groups of infants with normal FMs and abnormal FMs in PT in supine showed significant differences for all parameters that described spontaneous CoP displacement. The reliability analysis determined that all ICCs of the outcomes presented at least a moderate level of reliability. The ICCs were higher for outcomes of PT performed in the supine position than in the prone position. The ICCs were higher for outcomes of PT performed in infants with abnormal vs. normal FMs. Conclusions: although the current study yielded promising results, further longitudinal research in preterm infants should identify whether altered postural control parameters prognose future motor outcomes.