Benjamin Shani

Benjamin Shani

Auto-generated profile, based on publicly available information

Benjamin Shani

Maryland Power Electronics Laboratory, Department of Electrical and Computer Engineering, Institute for Systems Research, University of Maryland, College Park, MD, USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
HYHuseyin Ayhan Yavasoglu
Huseyin Ayhan Yavasoglu
BSBenjamin Shani
Benjamin Shani
AHArafat Hasnain
Arafat Hasnain
BPBerke Ogulcan Parlak
Berke Ogulcan Parlak
AKAlireza Khaligh
Alireza Khaligh
Vehicle integrated photovoltaics (VIPV) is an emerging technology requiring multidimensional analysis to support its standardization and adoption in electric vehicles (EVs). This study examines the integration of photovoltaic (PV) systems into EVs, focusing on dc–dc converter topologies transferring solar energy to the vehicle’s low-voltage (LV) electrical system across various auxiliary battery voltage levels. Three converter topologies, dual-active bridge (DAB), LLC, and flyback converters, are evaluated in terms of efficiency, cost, and volume. System performance is assessed under defined daily driving scenarios and auxiliary load profiles in two U.S. regions, Maryland and Arizona, which differ significantly in solar irradiance. A case study shows VIPV systems can supply up to 60.5% of annual secondary electrical load demands. The findings highlight that the choice of converter topology has a substantial impact on overall system efficiency and energy savings. Additionally, the study explores the environmental implications of large-scale VIPV adoption in the U.S. and globally, illustrating its potential to reduce the carbon footprint of EVs and advance sustainable transportation.

9 October 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
AAAyooluwa Ajiboye
Ayooluwa Ajiboye
CSChanaka Singhabahu
Chanaka Singhabahu
BSBenjamin Shani
Benjamin Shani
HCHassan Habib Chaudhry
Hassan Habib Chaudhry
AKAlireza Khaligh
Alireza Khaligh
This work proposes a single-port measurement scheme for extracting the impedance matrix ($\mathbf {Z}$-matrix) model parameters for the high-frequency magnetic link (HFML) of a multiactive bridge (MAB) converter, as opposed to individual, error-prone, two-port concurrent voltage–current measurements. The $\mathbf {Z}$-matrix is extracted over a wide-frequency range to estimate the HFML branch currents relative to other existing HFML models. The accuracy of the extracted $\mathbf {Z}$-matrix is verified by comparing the analytical estimates to steady-state experiments conducted on a 3.2 kW SiC four-port MAB prototype. The improved accuracy of the $\mathbf {Z}$-matrix over existing HFML models validates the proposed single-port parameter extraction method.

3 March 2026 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
AAAyooluwa Ajiboye
Ayooluwa Ajiboye
CSChanaka Singhabahu
Chanaka Singhabahu
BSBenjamin Shani
Benjamin Shani
AGAyodhya Somiruwan Gamwari
Ayodhya Somiruwan Gamwari
AKAlireza Khaligh
Alireza Khaligh
The multi-active bridge (MAB) converter has gained widespread adoption due to its multidirectional power flow via a galvanically isolated multi-winding magnetic structure. However, the mutually-shared magnetic link and inter-port phase-shifts induce the cross-coupled power flow which hinders independent port-wise operation. This work presents an analytical framework that combines port-equivalent models derived from a full-order $n \times n$ impedance matrix ($\bf {Z}$-matrix) with generalized harmonic analysis (GHA), to accurately capture the cross-coupled power flow in MAB converters. An experimental method based on steady-state tests is developed to characterize the cross-coupled active powers by isolating the inter-port power interactions. Thereafter, a control-integrated power decoupling (iPD) algorithm with feedforward compensation is developed to achieve port-wise decoupling by suppressing voltage fluctuations during transients. The required port-equivalent model parameters are obtained from the experimentally extracted $\bf {Z}$-matrix of the high-frequency magnetic link (HFML) via a proposed single-port impedance measurement scheme. The cross-coupling and decoupling frameworks are validated on a 2.4 kW SiC-based four-port MAB prototype. Transient experiments featuring both voltage- and load-step variations are used to verify the effectiveness and improved decoupling performance of the proposed $\bf {Z}$-matrix iPD strategy, relative to the uncompensated PI controller baseline, and the reduced-order $Y$-$\Delta$ (star-delta) feedforward scheme.

1 July 2026 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
AAAyooluwa Ajiboye
Ayooluwa Ajiboye
CSChanaka Singhabahu
Chanaka Singhabahu
BSBenjamin Shani
Benjamin Shani
HCHassan Habib Chaudhry
Hassan Habib Chaudhry
AKAlireza Khaligh
Alireza Khaligh
The principal component within the multi active bridge (MAB) topology is the high-frequency magnetic link (HFML) interconnecting multiple ports, thereby facilitating multidirectional power flow. However, a byproduct of this unifying AC magnetic link is the cross-coupled power flow induced by the inter-port phase shifts, subsequently preventing independent port-wise operation. Therefore, this work presents a time-domain analytical framework for the accurate estimation of the cross-coupled active power flow by applying a superposition-based approach to the MAB port-equivalent models. These port-equivalent models are derived from the full-order $n \times n$ inductance matrix ($\mathbf {L}$-matrix) extracted from an asymmetric integrated-leakage HFML via a single-port impedance measurement scheme. Furthermore, a control-integrated power decoupling (IPD) feedforward compensator is developed to suppress undesirable propagative voltage fluctuations during transient power flows, thereby ensuring port-wise decoupling of the converter. Steady-state experiments conducted on a 3.2 kW SiC-based four-port MAB prototype are used to validate the accuracy of the proposed time-domain model with respect to the terminal active powers. Whereas transient experiments with output-voltage step-changes are used to verify the improved decoupling performance of the proposed full-order $\mathbf {L}$-matrix IPD scheme, in comparison with an uncompensated PI (Proportional-Integral) controller, and the existing $Y$-$\Delta$ (star-delta) decoupling method.


22 January 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DZDaniel Zakzewski
Daniel Zakzewski
BSBenjamin Shani
Benjamin Shani
AAAyooluwa Ajiboye
Ayooluwa Ajiboye
AKAlireza Khaligh
Alireza Khaligh
Hybrid neutral-point clamped (HNPC) converters have received a wide-level of research focus in multilevel inverter applications due to their power quality and loss-improvement benefits. However, these converters are typically limited to a singular floating H-bridge (FHB) stage due to complex capacitor regulation and poor device utilization as compared with multilevel designs using flying capacitor stages. Therefore, this work proposes a 19-level topology consisting of a 3L-active neutral point clamped (ANPC) base cascaded with two FHB stages, thereby enabling several improvements to the conventional FHB-based HNPC converter. As opposed to traditional modulation techniques, which achieve nine-levels, the proposed method includes a novel use of trinary level scaling, which expands the number of output levels to 19 in the normal modulation range, and up to 23 in the extended modulation range. This results in major benefits such as the decreased switch voltage ratings, improved output power quality, and enhanced power density. Furthermore, this work introduces a joint-phase redundancy balancing technique combined with a multiobjective finite control-set model predictive control (FCS-MPC) algorithm aimed at achieving switching loss minimization and strict floating capacitor voltage regulation at the switching frequency level. The proposed FCS-MPC strategy simplifies the calculation of the available redundancies in the HNPC converter, enabling feasibility of implementation on a standard microcontroller with execution times compatible with switching-frequency synchronous control. To validate the proposed topology and control strategy, steady-state and transient experiments are conducted on a 2 kW HNPC prototype. The results clearly demonstrate significant performance improvements, thereby confirming the advantages of the proposed solution in practical applications.