Bus-clamping Pulse Width Modulation (PWM) is an effective method to reduce the switching loss in a three-phase voltage source inverter (VSI). In bus-clamping PWM scheme, the phase legs are switched using high frequency PWM signals for two-third of the line cycle, while for the remaining duration of cycle, the pole voltage is clamped to either positive or negative rail of the DC bus. In PWM operation of a half bridge, a dead-time is applied between the gate signals of complementary switches to ensure safe and reliable operation. However, introduction of dead-time leads to poor power quality, increased Total Harmonic Distortion (THD) and variation in actual voltage compared to the intended pole voltage. Moreover, when the bus-clamping technique is used, the PWM has both high frequency switching region and clamped region in a line cycle, and consequently, the undesired effects of dead-time are further aggravated. Therefore, in order to enhance the quality of output voltage, this paper presents a dead-time compensation strategy for a VSI operating with bus-clamping PWM. The proposed method calculates the required compensation term to be added on the modulation signal considering wide range of operating conditions. Additionally, the compensation includes a new strategy for low current conditions near zero-crossing to avoid distortion. The proposed method is verified by simulation and experiments in a three-phase VSI with a switching frequency of 100 kHz and a fundamental frequency of 60Hz.
12 August 2024 in IEEE Transactions on Power Electronics
Multiactive-bridge (MAB) converter is gaining high interest as a multiport converter topology due to its multidirectional power flow capability, zero voltage switching, and galvanic isolation between ports with voltage step-up/down. One of the key components of the MAB converter is the high-frequency $n$ -port magnetic link. An $n \times n$ impedance matrix is a full order model to represent an $n$ -port passive network, without losing any information seen from the ports. In this work, a full-order impedance matrix-based model for an MAB converter is introduced, and a systematic approach is devised to find the optimal modulation parameters which minimize the converter losses. This approach is deployed to obtain desired power flow, minimize conduction losses, and analyze zero-voltage-switching (ZVS) conditions. A frequency domain model is developed which uses the impedance matrix to solve for the branch currents. The inductance matrix of the high-frequency ac link is further used with the frequency domain model to analyze the port ZVS conditions by investigating the inductive energy in the high frequency ac link. The work is experimentally verified on a GaN based four-port 250-W MAB converter with its ports rated at 200 V, 30 V, 16 V, and 8 V.
20 May 2025 in IEEE Transactions on Transportation Electrification
The three-level T-type (3LTT) inverter incorporates two cascaded dc-link capacitors that share a common coupling node (CCN) known as neutral point. During the operation of T-type inverter, the CCN voltage oscillates at triple the line frequency. Furthermore, in some applications such as dual-input photovoltaic systems, there may be a dc voltage imbalance across dc-link capacitors, resulting in an unbalanced CCN voltage. The presence of an unbalanced or oscillating CCN voltage in T-type inverter affects the quality of output current and voltage waveform by introducing low-frequency harmonics. To address this issue, this article proposes a novel modulation method to compensate the effects of unbalanced and oscillating CCN voltage, enabling the generation of nondistorted phase voltage and current. By enhancing the output waveforms quality, the proposed method can result in reduction of the dc-link capacitor size and improvement of power density in the T-type inverter. In this method, the modulation signal is adjusted using simple mathematical calculations based on the sensed CCN and dc-link voltage, which imposes negligible processing time on the microcontroller. This method is applicable across the entire range of operation, regardless of load power factor or modulation index. Furthermore, the proposed method preserves the high-quality and sinusoidal shape of output current waveform even under dynamic disturbances in the CCN and dc-link voltage. To provide further insight, the normalized increase in total semiconductor loss due to the implementation of the proposed method is also evaluated. Finally, the analytical and experimental results are conducted to validate the effectiveness of the proposed compensating method.
9 October 2025 in IEEE Transactions on Power Electronics
This work proposes a single-port measurement scheme for extracting the impedance matrix ($\mathbf {Z}$-matrix) model parameters for the high-frequency magnetic link (HFML) of a multiactive bridge (MAB) converter, as opposed to individual, error-prone, two-port concurrent voltage–current measurements. The $\mathbf {Z}$-matrix is extracted over a wide-frequency range to estimate the HFML branch currents relative to other existing HFML models. The accuracy of the extracted $\mathbf {Z}$-matrix is verified by comparing the analytical estimates to steady-state experiments conducted on a 3.2 kW SiC four-port MAB prototype. The improved accuracy of the $\mathbf {Z}$-matrix over existing HFML models validates the proposed single-port parameter extraction method.
3 March 2026 in IEEE Transactions on Power Electronics
The multi-active bridge (MAB) converter has gained widespread adoption due to its multidirectional power flow via a galvanically isolated multi-winding magnetic structure. However, the mutually-shared magnetic link and inter-port phase-shifts induce the cross-coupled power flow which hinders independent port-wise operation. This work presents an analytical framework that combines port-equivalent models derived from a full-order $n \times n$ impedance matrix ($\bf {Z}$-matrix) with generalized harmonic analysis (GHA), to accurately capture the cross-coupled power flow in MAB converters. An experimental method based on steady-state tests is developed to characterize the cross-coupled active powers by isolating the inter-port power interactions. Thereafter, a control-integrated power decoupling (iPD) algorithm with feedforward compensation is developed to achieve port-wise decoupling by suppressing voltage fluctuations during transients. The required port-equivalent model parameters are obtained from the experimentally extracted $\bf {Z}$-matrix of the high-frequency magnetic link (HFML) via a proposed single-port impedance measurement scheme. The cross-coupling and decoupling frameworks are validated on a 2.4 kW SiC-based four-port MAB prototype. Transient experiments featuring both voltage- and load-step variations are used to verify the effectiveness and improved decoupling performance of the proposed $\bf {Z}$-matrix iPD strategy, relative to the uncompensated PI controller baseline, and the reduced-order $Y$-$\Delta$ (star-delta) feedforward scheme.
1 July 2026 in IEEE Transactions on Power Electronics
The principal component within the multi active bridge (MAB) topology is the high-frequency magnetic link (HFML) interconnecting multiple ports, thereby facilitating multidirectional power flow. However, a byproduct of this unifying AC magnetic link is the cross-coupled power flow induced by the inter-port phase shifts, subsequently preventing independent port-wise operation. Therefore, this work presents a time-domain analytical framework for the accurate estimation of the cross-coupled active power flow by applying a superposition-based approach to the MAB port-equivalent models. These port-equivalent models are derived from the full-order $n \times n$ inductance matrix ($\mathbf {L}$-matrix) extracted from an asymmetric integrated-leakage HFML via a single-port impedance measurement scheme. Furthermore, a control-integrated power decoupling (IPD) feedforward compensator is developed to suppress undesirable propagative voltage fluctuations during transient power flows, thereby ensuring port-wise decoupling of the converter. Steady-state experiments conducted on a 3.2 kW SiC-based four-port MAB prototype are used to validate the accuracy of the proposed time-domain model with respect to the terminal active powers. Whereas transient experiments with output-voltage step-changes are used to verify the improved decoupling performance of the proposed full-order $\mathbf {L}$-matrix IPD scheme, in comparison with an uncompensated PI (Proportional-Integral) controller, and the existing $Y$-$\Delta$ (star-delta) decoupling method.