Seong Jong Hong

Seong Jong Hong

Auto-generated profile, based on publicly available information

Seong Jong Hong

Eulji University, Graduate School of Eulji University, Department of Senior Healthcare, Uijeongbu-si, Republic of Korea

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
HKHan Gyu Kang
Han Gyu Kang
TYTaiga Yamaya
Taiga Yamaya
YHYoung Been Han
Young Been Han
SSSeong Hyun Song
Seong Hyun Song
GKGuen Bae Ko
Guen Bae Ko
SHSeong Jong Hong
Seong Jong Hong
Silicon photomultipliers (SiPMs) are now widely used for positron emission tomography (PET) applications because of their high gain and low noise characteristics. The PET image quality has been improved with the advancement of time-of-flight (TOF) and depth-of-interaction (DOI) measurement techniques. For brain-dedicated PET systems, both TOF and DOI information are beneficial for enhancing the reconstructed PET image quality. In a previous study, we proposed SiPM-based dual-ended readout PET detectors that used a mean time method to achieve coincidence timing resolution (CTR) of 349 ps and DOI resolution of 2.9 mm. However, the coincidence timing resolution (CTR) was worse than 300 ps since the crystal surface and the reflector type were not optimized. This study aimed at investigating the optimal crystal surface treatment and the reflector material to achieve a sub-200 ps CTR and sub-3 mm DOI resolution with a dual-ended readout PET detector using an LYSO crystal (2.9 × 2.9 × 20 mm 3 ). The scintillation light inside the LYSO crystal was read out by two SiPMs using the dual-ended readout method. The CTR and DOI resolution were measured with two different crystal surfaces (polished and saw-cut) and three different reflector material scenarios of ESR without grease (i.e., air coupling), ESR with optical grease and Teflon. We digitized the timing and energy signals by using a V775N TDC module (35 ps bit −1 ) and V965 QDC module, respectively. The combination of the saw-cut LYSO crystal and the ESR with air coupling resulted in the best CTR (188 ± 32 ps) and DOI resolution (2.9 ± 0.2 mm) with the dual-ended readout configuration. We concluded the dual-ended readout method in combination with the saw-cut crystal and the ESR reflector with air coupling can provide a sub-200 ps CTR and sub-3.0 mm DOI resolution simultaneously.

22 March 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
HKHan Gyu Kang
Han Gyu Kang
SSSeong Hyun Song
Seong Hyun Song
YHYoung Been Han
Young Been Han
HLHo-Young Lee
Ho-Young Lee
KKKyeong Min Kim
Kyeong Min Kim
SHSeong Jong Hong
Seong Jong Hong
An optical/nuclear hybrid surgical technique using ICG-99mTc-nanocolloid can improve lesion detectability by detecting both fluorescence and gamma signals. However, a hybrid multimodal laparoscope that can obtain both NIR and gamma images is not available yet. In this work, we present a proof-of-concept study of a prototype multimodal laparoscope that can provide simultaneous NIR/gamma/visible imaging using wavelength division multiplexing. The performances of optical and gamma imaging were evaluated using a USAF 1951 negative resolution target and 99mTc-filled tumor-like sources, respectively. Simultaneous NIR/gamma/visible images of two Eppendorf tubes containing a mixture of 99mTc-ICG are presented.

1 February 2019 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
YHY.B. Han
Y.B. Han
HKHan Gyu Kang
Han Gyu Kang
SSS.H. Song
S.H. Song
GKG.B. Ko
G.B. Ko
JLJ.S. Lee
J.S. Lee
SHS.J. Hong
S.J. Hong

28 November 2016 in Medical Physics
Verified
Journal Article
Closed access
PDF file
HKHan Gyu Kang
Han Gyu Kang
HLHo‐Young Lee
Ho‐Young Lee
KKKyeong Min Kim
Kyeong Min Kim
SSSeong‐Hyun Song
Seong‐Hyun Song
GHGun Chul Hong
Gun Chul Hong
SHSeong Jong Hong
Seong Jong Hong

1 December 1997 in Physics Letters B
Verified
Journal Article
Open access
Maurizio Filippo AcciarriMaurizio Filippo Acciarri
Maurizio Filippo Acciarri
OAOscar Adriani
Oscar Adriani
MAM. Aguilar-Benitez
M. Aguilar-Benitez
SASteven Ahlen
Steven Ahlen
JAJ. Alcaraz
J. Alcaraz
FZF. Ziegler
F. Ziegler
A search for single and multi-photon events with missing energy is performed using data collected at centre-of-mass energies between 161 GeV and 172 GeV for a total of 20.9 pb −1 of integrated luminosity. The results obtained are used to derive the value for the ν ν γ(γ) cross section as well as upper limits on new physics processes

13 January 2021 in Optics Express
Verified
Journal Article
Open access
PDF file
YHYoung Been Han
Young Been Han
SSSeong Hyun Song
Seong Hyun Song
HKHan Gyu Kang
Han Gyu Kang
HLHo-Young Lee
Ho-Young Lee
SHSeong Jong Hong
Seong Jong Hong
Intraoperative imaging has been studied using conventional devices such as near infrared (NIR) optical probes and gamma probes. However, these devices have limited depth penetration and spatial resolution. In a previous study, we realized a multi-modal endoscopic system. However, charge-coupled device (CCD)-based gamma imaging required long acquisition times and lacked gamma energy information. A silicon photomultiplier (SiPM)-based gamma detector is implemented in a multi-modal laparoscope herein. A gradient index (GRIN) lens and CCD are used to transfer and readout visible and NIR photons. The feasibility of in-vivo sentinel lymph node (SLN) mapping was successfully performed with the proposed system.