Han Gyu Kang

Mr. Han Gyu Kang


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DSDavid Sarrut
David Sarrut
NANicolas Arbor
Nicolas Arbor
TBThomas Baudier
Thomas Baudier
DBDamian Borys
Damian Borys
AEAne Etxebeste
Ane Etxebeste
LMLydia Maigne
Lydia Maigne
This paper reviews the ecosystem of GATE, an open-source Monte Carlo toolkit for medical physics. Based on the shoulders of Geant4, the principal modules (geometry, physics, scorers) are described with brief descriptions of some key concepts (Volume, Actors, Digitizer). The main source code repositories are detailed together with the automated compilation and tests processes (Continuous Integration). We then described how the OpenGATE collaboration managed the collaborative development of about one hundred developers during almost 20 years. The impact of GATE on medical physics and cancer research is then summarized, and examples of a few key applications are given. Finally, future development perspectives are indicated.

10 September 2015 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
HKHan Gyu Kang
Han Gyu Kang
GKGuen Bae Ko
Guen Bae Ko
JRJune Tak Rhee
June Tak Rhee
KKKyeong Min Kim
Kyeong Min Kim
JLJae Sung Lee
Jae Sung Lee
SHSeong Jong Hong
Seong Jong Hong
We have investigated a dual-ended readout detector based on two silicon photo-multipliers (SiPMs) using a 30 mm long cerium-doped lutetium-yttrium oxyorthosilicate ( Lu0.5Y1.4Si0.5:Ce, LYSO) crystal to study the feasibility of a time-of-flight (TOF) and depth-of-interaction (DOI) positron emission tomography (PET). To improve the timing resolution in the dual-ended readout detector, a novel meantime measurement was employed. The meantime was obtained by averaging two signal arrival times at two SiPMs, each of which was attached to both ends of the LYSO crystal. The meantime method minimizes the arrival time difference along the crystal. Both timing and DOI resolutions using the meantime method were better than those of a single-ended readout detector.

29 December 2022 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
HKHan Gyu Kang
Han Gyu Kang
HTHideaki Tashima
Hideaki Tashima
HWHidekatsu Wakizaka
Hidekatsu Wakizaka
FNFumihiko Nishikido
Fumihiko Nishikido
MHMakoto Higuchi
Makoto Higuchi
TYTaiga Yamaya
Taiga Yamaya
PET is a powerful molecular imaging technique that can provide functional information on living objects. However, the spatial resolution of PET imaging has been limited to around 1 mm, which makes it difficult to visualize mouse brain function in detail. Here, we report an ultrahigh-resolution small-animal PET scanner we developed that can provide a resolution approaching 0.6 mm to visualize mouse brain function with unprecedented detail. Methods: The ultrahigh-resolution small-animal PET scanner has an inner diameter of 52.5 mm and axial coverage of 51.5 mm. The scanner consists of 4 rings, each of which has 16 depth-of-interaction detectors. Each depth-of-interaction detector consists of a 3-layer staggered lutetium yttrium orthosilicate crystal array with a pitch of 1 mm and a 4 × 4 silicon photomultiplier array. The physical performance was evaluated in accordance with the National Electrical Manufacturers Association NU4 protocol. Spatial resolution was evaluated with phantoms of various resolutions. In vivo glucose metabolism imaging of the mouse brain was performed. Results: Peak absolute sensitivity was 2.84% with an energy window of 400–600 keV. The 0.55-mm rod structure of a resolution phantom was resolved using an iterative algorithm. In vivo mouse brain imaging with 18F-FDG clearly identified the cortex, thalamus, and hypothalamus, which were barely distinguishable in a commercial preclinical PET scanner that we used for comparison. Conclusion: The ultrahigh-resolution small-animal PET scanner is a promising molecular imaging tool for neuroscience research using rodent models. Visual Abstract

30 May 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
SHSeong Jong Hong
Seong Jong Hong
HKHan Gyu Kang
Han Gyu Kang
GKGuen Bae Ko
Guen Bae Ko
ISIn Chan Song
In Chan Song
JRJune-Tak Rhee
June-Tak Rhee
JLJae Sung Lee
Jae Sung Lee
For positron emission tomography (PET) inserts to magnetic resonance imaging (MRI) applications, optical fibers have been used for some time to transfer scintillation photons to photomultiplier tubes positioned outside the fringe magnetic field. We previously proposed a novel utilization of an optical fiber for good radio frequency (RF) transmission from body coils to an imaging object. Optical fiber bundles between silicon photomultipliers (SiPM) and scintillation crystals provide an increased spacing between RF-shielded electronics boxes, facilitating RF passage from the body RF coils to imaging objects. In this paper, we present test results of a SiPM-PET system with a short optical fiber bundle for simultaneous PET-MR imaging. We built the SiPM-PET system which consisted of 12 SiPM-PET modules; each module was assembled with a lutetium yttrium oxyorthosilicatecrystal block, a 31 mm optical fiber bundle, a Hamamatsu multi-pixel photon counter S11064-050P and a signal processing box shielded with copper. The SiPM-PET system, with a face-to-face distance of 71 mm, was placed inside a 3 T MRI. A small surface coil placed inside the SiPM-PET system was used to receive the signal from phantoms while the body RF coil transmitted the RF pulses. The SiPM-PET system showed little performance degradation during the simultaneous PET-MR imaging and it caused no significant degradation of MR images with turbo spin echo (TSE), gradient echo or 3D spoiled gradient recalled sequences. Echo planar imaging MR images with and without the SiPM-PET inside the MR scanner were significantly worse than the images obtained with the TSE sequence.

1 November 2020 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
HKHan Gyu Kang
Han Gyu Kang
TYTaiga Yamaya
Taiga Yamaya
YHYoung Been Han
Young Been Han
SSSeong Hyun Song
Seong Hyun Song
GKGuen Bae Ko
Guen Bae Ko
SHSeong Jong Hong
Seong Jong Hong
Silicon photomultipliers (SiPMs) are now widely used for positron emission tomography (PET) applications because of their high gain and low noise characteristics. The PET image quality has been improved with the advancement of time-of-flight (TOF) and depth-of-interaction (DOI) measurement techniques. For brain-dedicated PET systems, both TOF and DOI information are beneficial for enhancing the reconstructed PET image quality. In a previous study, we proposed SiPM-based dual-ended readout PET detectors that used a mean time method to achieve coincidence timing resolution (CTR) of 349 ps and DOI resolution of 2.9 mm. However, the coincidence timing resolution (CTR) was worse than 300 ps since the crystal surface and the reflector type were not optimized. This study aimed at investigating the optimal crystal surface treatment and the reflector material to achieve a sub-200 ps CTR and sub-3 mm DOI resolution with a dual-ended readout PET detector using an LYSO crystal (2.9 × 2.9 × 20 mm 3 ). The scintillation light inside the LYSO crystal was read out by two SiPMs using the dual-ended readout method. The CTR and DOI resolution were measured with two different crystal surfaces (polished and saw-cut) and three different reflector material scenarios of ESR without grease (i.e., air coupling), ESR with optical grease and Teflon. We digitized the timing and energy signals by using a V775N TDC module (35 ps bit −1 ) and V965 QDC module, respectively. The combination of the saw-cut LYSO crystal and the ESR with air coupling resulted in the best CTR (188 ± 32 ps) and DOI resolution (2.9 ± 0.2 mm) with the dual-ended readout configuration. We concluded the dual-ended readout method in combination with the saw-cut crystal and the ESR reflector with air coupling can provide a sub-200 ps CTR and sub-3.0 mm DOI resolution simultaneously.

28 April 2021 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
HKHan Gyu Kang
Han Gyu Kang
FNFumihiko Nishikido
Fumihiko Nishikido
TYTaiga Yamaya
Taiga Yamaya
The spatial resolution of small animal positron emission tomography (PET) scanners can be improved by the use of crystals with fine pitch and rejection of inter-crystal scattering (ICS) events, which leads to a better quantification of radiopharmaceuticals. On the other hand, depth-of-interaction (DOI) information is essential to preserve the spatial resolution at the PET field-of-view (FOV) periphery while keeping the sensitivity. In this study we proposed a novel staggered 3-layer DOI detector using BaSO 4 reflector material for an enhanced crystal identification performance as well as ICS event rejection capability over those of ESR reflector based DOI detectors. The proposed staggered 3-layer DOI detector had 3-layer staggered LYSO crystal arrays (crystal pitch = 1 mm), an acrylic light guide, and a 4 × 4 SiPM array. The 16 SiPM anode signals were read out by using a resistive network to encode the crystal position and energy information while the timing signal was extracted from the common cathode. The crystal map quality was substantially enhanced by using the BaSO 4 reflector material as compared to that of the ESR reflector due to the low optical crosstalk between the LYSO crystals. The ICS events can be rejected with BaSO 4 by using simple pulse height discrimination thanks to the light collection efficiency difference that depends on the crystal layers. As a result, the total number of events was decreased around 26% with BaSO 4 as compared to that of ESR. The overall energy resolution and coincidence timing resolution with BaSO 4 were 19.7 ± 5.6% and 591 ± 160 ps, respectively which were significantly worse than 10.9 ± 2.2% and 308 ± 23 ps values of ESR because of the relatively low light collection efficiency with BaSO 4 (1057 ± 308 ADC) compared to that of ESR (1808 ± 118 ADC). In conclusion, we found the proposed staggered 3-layer DOI detector using the BaSO 4 reflector material with ICS event rejection capability can be a cost-effective solution for realizing high resolution and highly sensitive small animal PET scanners while minimizing the complexity of the SiPM readout circuit.