20 May 2020 in IEEE Access
A novel pattern and polarization reconfigurable wearable slot antenna suitable for smart glasses is proposed. The antenna is designed and fabricated on glass and reconfiguration is realized using four PIN diodes. It operates in the 2.4 GHz Industrial, Scientific and Medical Band. It consists of an equilateral L-shaped slot fed by a single coplanar waveguide feed. The slot is manipulated with switches to generate two modes of operation. Each mode corresponds to one of the two states of the switches which result in different L-shaped slots with unequal legs creating patterns that are polarized in perpendicular to each other. The antenna has been shown to perform well near the human body using numerical and physical phantoms. The correlation between the two modes is calculated to be less than 0.04 with 41% and 56% onbody efficiency for each mode. The Specific Absorption Rate is shown to be well below the limit specified in the European Standards through simulations.
20 September 2021 in IEEE Transactions on Antennas and Propagation
A novel wearable cavity-backed slot repeater antenna is presented to improve the link between implant antennas and the outside world. This proposed repeater antenna consists of two slots on opposite sides of a shallow rectangular cavity. These slots are activated in an alternating way, selecting the mode of operation: in-body or off-body. Through the antenna’s in-body mode, signals transmitted by the implant antenna are received and conveyed to the off-body gateway via its off-body mode. Both modes are designed to operate in the 2.4 GHz industrial, scientific, and medical (ISM) Band. The antenna is fed by a single diagonal stripline, and the two slots encounter the stripline at the same location with impedance matching obtained through offset feeding. The antenna has an overall size of 33.5 mm $\times 37$ mm $\times 3.14$ mm and has been shown to perform well near numerical and physical phantoms, communicating with deep tissue implants with an outstanding maximum $|{S_{21}}|$ value of −37.4 dB measured at 6 cm depth.
1 September 2017 in IEEE Transactions on Antennas and Propagation
Modern body-centric communication systems require good link quality. Antenna performance is of primary importance when meeting this requirement. This paper contributes a method suited to the difficult task of quantifying antenna performance in a body-centric communications system. In a case study, a planar wrist wearable antenna, which provides radiation pattern switching across the 2.4 GHz operating band through an innovative technique that does not require an additional switching mechanism, is benchmarked against a monopole and a patch antenna in a residential setting. The performance of the antenna and subsequently the benefits of the pattern-switching technique are successfully quantified. The holistic method includes both antenna measurements and channel simulation with ray tracing. Results are verified against real-world measurements.
13 December 2023 in IEEE Antennas and Propagation Magazine
Synthetic biology has the potential to drastically change sensor technologies. Living cells can now be genetically programmed to be responsive to specific molecules. If those living cells are supported to live inside a host body, in vivo sensing at a molecular level can be achieved. However, the communication link between the genetically modified cells and the outside of the host body is an open area of research. Here, we propose a generic wireless communication platform that we call AntennAlive to bridge this gap. The link described can be considered as a gateway between the molecular links that are used by living cells and electromagnetic links. It is a groundbreaking proposition that will initiate a new area of research where antenna design meets synthetic biology. As an example, a biohybrid implant consisting of engineered skeletal muscle and a reconfigurable implant antenna is described. The implant antenna is used as a passive reflector that is reconfigured by the contraction of the skeletal muscle initiated with a trigger molecule that we are interested in sensing. This reconfiguration is tracked by an on-body reader that completes the wireless link. Note that here sensing is realized with skeletal muscle for the first time in the literature.
11 January 2022 in IEEE Transactions on Antennas and Propagation
Matching media are used in various applications to increase the power transmitted into the human body. The selection of the optimum matching medium permittivity is not a straightforward task, as the optimum value maximizing the transmitted power depends on the thickness of the matching medium and the electromagnetic properties of the target tissue. In this paper, a computationally heavy empirical approach and a machine learning-based approach are utilized for the selection of the matching medium. The empirical approach demonstrates that the matching medium can increase the |S21| values up to 8 dB, which is validated with measurements. Next, a machine learning-based tool is proposed to predict the optimum matching medium permittivity for any target tissue and any matching medium thickness. A one-dimensional convolutional neural network followed by a multi-layer perceptron is trained with the simulated average Poynting vector magnitudes for muscle and fat as target tissues. The average Poynting vector magnitude and the dipole length for given system parameters are predicted by the trained artificial neural network. The accuracy is calculated by comparison with the results of the empirical analysis and found to be 1% and 12.3% mean absolute percentage error for dipole length and average Poynting vector magnitude, respectively. The proposed tool decreases the time required to milliseconds.