20 September 2021 in IEEE Transactions on Antennas and Propagation
A novel wearable cavity-backed slot repeater antenna is presented to improve the link between implant antennas and the outside world. This proposed repeater antenna consists of two slots on opposite sides of a shallow rectangular cavity. These slots are activated in an alternating way, selecting the mode of operation: in-body or off-body. Through the antenna’s in-body mode, signals transmitted by the implant antenna are received and conveyed to the off-body gateway via its off-body mode. Both modes are designed to operate in the 2.4 GHz industrial, scientific, and medical (ISM) Band. The antenna is fed by a single diagonal stripline, and the two slots encounter the stripline at the same location with impedance matching obtained through offset feeding. The antenna has an overall size of 33.5 mm $\times 37$ mm $\times 3.14$ mm and has been shown to perform well near numerical and physical phantoms, communicating with deep tissue implants with an outstanding maximum $|{S_{21}}|$ value of −37.4 dB measured at 6 cm depth.
11 January 2022 in IEEE Transactions on Antennas and Propagation
Matching media are used in various applications to increase the power transmitted into the human body. The selection of the optimum matching medium permittivity is not a straightforward task, as the optimum value maximizing the transmitted power depends on the thickness of the matching medium and the electromagnetic properties of the target tissue. In this paper, a computationally heavy empirical approach and a machine learning-based approach are utilized for the selection of the matching medium. The empirical approach demonstrates that the matching medium can increase the |S21| values up to 8 dB, which is validated with measurements. Next, a machine learning-based tool is proposed to predict the optimum matching medium permittivity for any target tissue and any matching medium thickness. A one-dimensional convolutional neural network followed by a multi-layer perceptron is trained with the simulated average Poynting vector magnitudes for muscle and fat as target tissues. The average Poynting vector magnitude and the dipole length for given system parameters are predicted by the trained artificial neural network. The accuracy is calculated by comparison with the results of the empirical analysis and found to be 1% and 12.3% mean absolute percentage error for dipole length and average Poynting vector magnitude, respectively. The proposed tool decreases the time required to milliseconds.