Ralf Deichmann

Ralf Deichmann

Auto-generated profile, based on publicly available information

Ralf Deichmann

Goethe University Frankfurt Cooperative Brain Imaging Center – CoBIC Frankfurt am Main Germany

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in NeuroImage: Clinical
Verified
Journal Article
Open access
LNLucas Nürnberger
Lucas Nürnberger
RGRené-Maxime Gracien
René-Maxime Gracien
PHPavel Hok
Pavel Hok
SHStephanie-Michelle Hof
Stephanie-Michelle Hof
URUdo Rüb
Udo Rüb
SBSimon Baudrexel
Simon Baudrexel
Histological evidence suggests that pathology in Parkinson's disease (PD) goes beyond nigrostriatal degeneration and also affects the cerebral cortex. Quantitative MRI (qMRI) techniques allow the assessment of changes in brain tissue composition. However, the development and pattern of disease-related cortical changes have not yet been demonstrated in PD with qMRI methods. The aim of this study was to investigate longitudinal cortical microstructural changes in PD with quantitative T1 relaxometry. 13 patients with mild to moderate PD and 20 matched healthy subjects underwent high resolution T1 mapping at two time points with an interval of 6.4 years (healthy subjects: 6.5 years). Data from two healthy subjects had to be excluded due to MRI artifacts. Surface-based analysis of cortical T1 values was performed with the FreeSurfer toolbox. In PD patients, a widespread decrease of cortical T1 was detected during follow-up which affected large parts of the temporo-parietal and occipital cortices and also frontal areas. In contrast, age-related T1 decrease in the healthy control group was much less pronounced and only found in lateral frontal, parietal and temporal areas. Average cortical T1 values did not differ between the groups at baseline (p = 0.17), but were reduced in patients at follow-up (p = 0.0004). Annualized relative changes of cortical T1 were higher in patients vs. healthy subjects (patients: - 0.72 ± 0.64%/year; healthy subjects: - 0.17 ± 0.41%/year, p = 0.007). In patients with PD, the development of widespread changes in cortical microstructure was observed as reflected by a reduction of cortical T1. The pattern of T1 decrease in PD patients exceeded the normal T1 decrease as found in physiological aging and showed considerable overlap with the pattern of cortical thinning demonstrated in previous PD studies. Therefore, cortical T1 might be a promising additional imaging marker for future longitudinal PD studies. The biological mechanisms underlying cortical T1 reductions remain to be further elucidated.

22 April 2009 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
NWNikolaus Weiskopf
Nikolaus Weiskopf
OJOliver Josephs
Oliver Josephs
CRChristian C. Ruff
Christian C. Ruff
FBFelix Blankenburg
Felix Blankenburg
EFEric Featherstone
Eric Featherstone
RDRalf Deichmann
Ralf Deichmann
Purpose: To characterize and eliminate a new type of image artifact in concurrent transcranial magnetic stimulation and functional MRI (TMS‐fMRI) caused by small leakage currents originating from the high‐voltage capacitors in the TMS stimulator system.Materials and Methods: The artifacts in echo‐planar images (EPI) caused by leakage currents were characterized and quantified in numerical simulations and phantom studies with different phantom‐coil geometries. A relay‐diode combination was devised and inserted in the TMS circuit that shorts the leakage current. Its effectiveness for artifact reduction was assessed in a phantom scan resembling a realistic TMS‐fMRI experiment.Results: The leakage‐current‐induced signal changes exhibited a multipolar spatial pattern and the maxima exceeded 1% at realistic coil‐cortex distances. The relay‐diode combination effectively reduced the artifact to a negligible level.Conclusion: The leakage‐current artifacts potentially obscure effects of interest or lead to false‐positives. Since the artifact depends on the experimental setup and design (eg, amplitude of the leakage current, coil orientation, paradigm, EPI parameters), we recommend its assessment for each experiment. The relay‐diode combination can eliminate the artifacts if necessary. J. Magn. Reson. Imaging 2009;29:1211–1217.

1 January 1995 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
RDR. Deichmann
R. Deichmann
HAH. Adolf
H. Adolf
UNU. Nöth
U. Nöth
SMS. Morrissey
S. Morrissey
CSC. Schwarzbauer
C. Schwarzbauer
AHA. Haase
A. Haase

1 September 1995 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
RDRalf Deichmann
Ralf Deichmann
HAHolger Adolf
Holger Adolf
UNUlrike Nöth
Ulrike Nöth
EKErwin Kuchenbrod
Erwin Kuchenbrod
CSChristian Schwarzbauer
Christian Schwarzbauer
AHAxel Haase
Axel Haase

1 February 1995 in Journal of Magnetic Resonance, Series B
Verified
Journal Article
Closed access
CSC. Schwarzbauer
C. Schwarzbauer
JZJochen Zange
Jochen Zange
HAH. Adolf
H. Adolf
RDR. Deichmann
R. Deichmann
UNU. Noth
U. Noth
AHA. Haase
A. Haase

10 May 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ASAlexander Seiler
Alexander Seiler
RDR. Deichmann
R. Deichmann
UNU. Nöth
U. Nöth
ALA. Lauer
A. Lauer
WPW. Pfeilschifter
W. Pfeilschifter
MWM. Wagner
M. Wagner
BACKGROUND AND PURPOSE: Chronic hemodynamic impairment in high-grade carotid occlusive disease is thought to cause microstructural abnormalities that might be subclinical or lead to subtle symptoms including cognitive impairment. Quantitative MR imaging allows assessing pathologic structural changes beyond macroscopically visible tissue damage. In this study, high-resolution quantitative T2 mapping combined with DSC-based PWI was used to investigate quantitative T2 changes as a potential marker of microstructural damage in relation to hemodynamic impairment in patients with unilateral high-grade carotid occlusive disease. MATERIALS AND METHODS: Eighteen patients with unilateral high-grade ICA or MCA stenosis/occlusion were included in the study. T2 values and deconvolved perfusion parameters, including relative CBF, relative CBV, and the relative CBF/relative CBV ratio as a potential indicator of local cerebral perfusion pressure, were determined within areas with delayed TTP and compared with values from contralateral unaffected areas after segmentation of normal-appearing hypoperfused WM and cortical regions. Hemispheric asymmetry indices were calculated for all parameters. RESULTS: Quantitative T2 was significantly prolonged (P < .01) in hypoperfused tissue and correlated significantly (P < .01) with TTP delay and relative CBF/relative CBV reduction in WM. Significant correlations (P < .001) between TTP delay and the relative CBF/relative CBV ratio were found both in WM and in cortical areas. CONCLUSIONS: Quantitative T2 can be used as a marker of microstructural tissue damage even in normal-appearing GM and WM within a vascular territory affected by high-grade carotid occlusive disease. Furthermore, the extent of damage correlates with the degree of hemodynamic failure measured by DSC perfusion parameters.