Kunal Vyas

Kunal Vyas

Auto-generated profile, based on publicly available information

Kunal Vyas

Lightpoint Medical Ltd Chesham UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2016 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MGMaarten R. Grootendorst
Maarten R. Grootendorst
MCMassimiliano Cariati
Massimiliano Cariati
SPSarah E. Pinder
Sarah E. Pinder
AKAshutosh Kothari
Ashutosh Kothari
MDMichael Douek
Michael Douek
APArnie David Purushotham
Arnie David Purushotham
In early-stage breast cancer, the primary treatment option for most women is breast-conserving surgery (BCS). There is a clear need for more accurate techniques to assess resection margins intraoperatively, because on average 20% of patients require further surgery to achieve clear margins. Cerenkov luminescence imaging (CLI) combines optical and molecular imaging by detecting light emitted by 18F-FDG. Its high-resolution and small size imaging equipment make CLI a promising technology for intraoperative margin assessment. A first-in-human study was conducted to evaluate the feasibility of 18F-FDG CLI for intraoperative assessment of tumor margins in BCS. Methods: Twenty-two patients with invasive breast cancer received 18F-FDG (5 MBq/kg) 45–60 min before surgery. Sentinel lymph node biopsy was performed using an increased 99mTc-nanocolloid activity of 150 MBq to facilitate nodal detection against the γ-probe background signal (cross-talk) from 18F-FDG. The cross-talk and 99mTc dose required was evaluated in 2 lead-in studies. Immediately after excision, specimens were imaged intraoperatively in an investigational CLI system. The first 10 patients were used to optimize the imaging protocol; the remaining 12 patients were included in the analysis dataset. Cerenkov luminescence images from incised BCS specimens were analyzed postoperatively by 2 surgeons blinded to the histopathology results, and mean radiance and margin distance were measured. The agreement between margin distance on CLI and histopathology was assessed. Radiation doses to staff were measured. Results: Ten of the 12 patients had an elevated tumor radiance on CLI. Mean radiance and tumor-to-background ratio were 560 ± 160 photons/s/cm2/sr and 2.41 ± 0.54, respectively. All 15 assessable margins were clear on CLI and histopathology. The agreement in margin distance and interrater agreement was good (κ = 0.81 and 0.912, respectively). Sentinel lymph nodes were successfully detected in all patients. The radiation dose to staff was low; surgeons received a mean dose of 34 ± 15 μSv per procedure. Conclusion: Intraoperative 18F-FDG CLI is a promising, low-risk technique for intraoperative assessment of tumor margins in BCS. A randomized controlled trial will evaluate the impact of this technique on reexcision rates.

11 April 2022 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
EPEdwin C. Pratt
Edwin C. Pratt
MSMagdalena Skubal
Magdalena Skubal
BLBenedict Mc Larney
Benedict Mc Larney
PCPamela Causa-Andrieu
Pamela Causa-Andrieu
SDSudeep Das
Sudeep Das
JGJan Grimm
Jan Grimm

25 April 2022 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
BHBaoru Huang
Baoru Huang
ANAnh Nguyen
Anh Nguyen
SWSiyao Wang
Siyao Wang
ZWZiyang Wang
Ziyang Wang
EMErik Mayer
Erik Mayer
DEDaniel S. Elson
Daniel S. Elson
Surgical instrument segmentation and depth estimation are crucial steps to improve autonomy in robotic surgery. Most recent works treat these problems separately, making the deployment challenging. In this paper, we propose a unified framework for depth estimation and surgical tool segmentation in laparoscopic images. The network has an encoder-decoder architecture and comprises two branches for simultaneously performing depth estimation and segmentation. To train the network end to end, we propose a new multi-task loss function that effectively learns to estimate depth in an unsupervised manner, while requiring only semi-ground truth for surgical tool segmentation. We conducted extensive experiments on different datasets to validate these findings. The results showed that the end-to-end network successfully improved the state-of-the-art for both tasks while reducing the complexity during their deployment.

24 October 2019 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
Judith Olde HeuvelJudith Olde Heuvel
Judith Olde Heuvel
BVBerlinda Jantina De Wit – Van Der Veen
Berlinda Jantina De Wit – Van Der Veen
KVK. N. Vyas
K. N. Vyas
DTD. S. Tuch
D. S. Tuch
MGM. R. Grootendorst
M. R. Grootendorst
CSC. H. Slump
C. H. Slump
Background: Cerenkov Luminescence Imaging (CLI) is an emerging technology for intraoperative margin assessment. Previous research only evaluated radionuclide 18-Fluorine (18F); however, for future applications in prostate cancer, 68-Gallium (68Ga) seems more suitable, given its higher positron energy. Theoretical calculations predict that 68Ga should offer a higher signal-to-noise ratio than 18F; this is the first experimental confirmation. The aim of this study is to investigate the technical performance of CLI by comparing 68Ga to 18F. Results: The linearity of the system, detection limit, spatial resolution, and uniformity were determined with the LightPath imaging system. All experiments were conducted with clinically relevant activity levels in vitro, using dedicated phantoms. For both radionuclides, a linear relationship between the activity concentration and detected light yield was observed (R2 = 0.99). 68Ga showed approximately 22 times more detectable Cerenkov signal compared to 18F. The detectable activity concentration after a 120 s exposure time and 2 × 2 binning of 18F was 23.7 kBq/mL and 1.2 kBq/mL for 68Ga. The spatial resolution was 1.31 mm for 18F and 1.40 mm for 68Ga. The coefficient of variance of the uniformity phantom was 0.07 for the central field of view. Conclusion: 68Ga was superior over 18F in terms of light yield and minimal detection limit. However, as could be expected, the resolution was 0.1 mm less for 68Ga. Given the clinical constraints of an acquisition time less than 120 s and a spatial resolution < 2 mm, CLI for intraoperative margin assessment using 68Ga could be feasible.

30 April 2021 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
Judith Olde HeuvelJudith Olde Heuvel
Judith Olde Heuvel
BVBerlinda Jantina De Wit – Van Der Veen
Berlinda Jantina De Wit – Van Der Veen
HPHenk G. van der Poel
Henk G. van der Poel
PLPim J. van Leeuwen
Pim J. van Leeuwen
EBElise M. Bekers
Elise M. Bekers
MSMarcel P.M. Stokkel
Marcel P.M. Stokkel
Introduction: Cerenkov luminescence imaging (CLI) is a novel imaging technology that might have the ability to assess surgical margins intra-operatively during prostatectomy using Gallium-68 prostate-specific membrane antigen ([68Ga]Ga-PSMA-11). This study evaluates the accuracy of CLI compared to histopathology and as exploratory objective investigates the characteristics of the identified chemiluminescence signal. Materials and Methods: After intravenous injection of a mean 68Ga-PSMA-11 activity of 69MBq intraoperatively, all excised specimens were imaged with CLI. Areas of increased signal were marked for histopathological comparison and scored for likelihood of being a positive surgical margin (PSM) using a 5-point Likert scale. In addition, the chemiluminescence signal was investigated in three radioactive and three non-radioactive specimens using CLI. Results: In 15 patients, the agreement between CLI and histopathology was 60%; this improved to 83% when including close surgical margins (≤1mm). In six hotspots, CLI correctly identified PSMs on histopathology, located at the apex and mid-prostate. In all 15 patients an increased signal at the prostate base was observed, without the presence of the primary tumor in this area in eight patients. This chemiluminescence signal was also observed in non-radioactive prostate specimens, with a half-life of 48±11min. The chemiluminescence hampered the visual interpretation of four PSMs at the base. Conclusion: CLI is able to correctly identify margin status, including close margins, in 83% of the cases. The presence of a diathermy-induced chemiluminescent signal hampered image interpretation, especially at the base of the prostate. In the current form, CLI is most applicable to detect PSMs and close margins in the apex and mid-prostate.

15 April 2010 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
THT J Hayward
T J Hayward
BHB Hong
B Hong
KVK N Vyas
K N Vyas
JPJ J Palfreyman
J J Palfreyman
JCJ F K Cooper
J F K Cooper
CBCrispin Henry William Barnes
Crispin Henry William Barnes