1 January 2017 in Advances in Materials Science and Engineering
This paper presents the results of a laboratory experiment that aimed to characterize the permanent deformation behavior of coarse grained soils. To evaluate the effects of the cyclic stress amplitude, initial mean stress, and initial stress ratio on the permanent axial deformation, six series of repeated load triaxial tests were performed. The results indicate that permanent deformation of coarse grained soils increased with increasing cyclic stress amplitude. In particular, for relative low cyclic stress levels, accumulation rate of permanent deformation decreased progressively with number of cycles and eventually reached an equilibrium state. The initial stress ratio was also found to obviously facilitate the buildup of axial deformation since it means higher deviatoric stress as the mean pressure kept constant. As the initial stress ratio was less than the slope of static failure line, the experimental results indicated that the increase of initial mean stress enhanced the capability of resisting deformation. A simplified mechanistic empirical prediction model was proposed, which predicted the permanent deformation as product of four independent functions about cyclic stress amplitude, initial mean stress, initial stress ratio, and number of load cycles. Satisfactory predictions of the permanent deformation behavior of coarse grained soils were obtained with the proposed model.
1 January 2017 in Shock and Vibration
This paper presents a field testing of track and ground-borne vibration generated by heavy haul trains. The test sites consisted of three embankments with height of 6.6, 8.1, and 11.9, respectively. The acceleration signals of the rail, sleeper, and embankment surface were recorded, and then the propagation characteristics of ground vibration with distance to track center were contrastively analyzed. The test results show that horizontal vibration was dominant for locations near the track but decreased rapidly and became comparable with the vertical levels as the distance from track center increases. The quasi-static excitation dominated the sleeper response, and the dominant frequency range was found in the low-frequency zone corresponding to the fundamental axle passage frequency. For embankment surface, another pronounced dominant frequency zone was observed between 30 and 80 Hz, which was attributed to the dynamic excitation. Moreover, these higher frequency components were more promptly attenuated than low-frequency ones. The reason that vibration levels generated by locomotive were greater than wagon was attributed to the different bogie suspension mode. The relationship between normalized PPV and distance from track center in doubly logarithmic scales can be expressed with exponential function, and the vibration attenuation rates were restrained with increasing the embankment height.
1 January 2021 in Shock and Vibration
Gravel cushions have been introduced as a practical and efficient seismic isolation technology to ensure the safety of nuclear power plants. This study investigated the seismic isolation effect of a gravel cushion by conducting a series of shaking table tests on a model foundation with a cushion built of three different types of graded aggregates (single‐sized (2–5 mm), two‐sized (2–5 mm:5–10 mm = 3 : 1), and continuously graded) under input El Centro seismic waves with three different peak accelerations (0.1 g, 0.2 g, and 0.3 g). The testing results showed that the seismic isolation effect of the gravel cushion increased with the peak seismic acceleration. The gravel cushion built with single‐sized aggregates had better seismic isolation performance than gravel cushions built with two‐sized or continuously graded aggregates. Under input seismic waves with 0.1 g peak acceleration, the single‐sized aggregate gravel cushion still had a seismic isolation effect with a vibration reduction rate of approximately 11.81%, whereas the other two gravel cushions had no effect. Under input seismic waves with peak accelerations of 0.2 g and 0.3 g, all three gravel cushions had seismic isolation effects with vibration reduction rates of approximately 18.63% and 17.92%, respectively. An empirical model is proposed for predicting the vibration reduction rate of the cushion. Under input seismic waves with 0.3 g peak acceleration, the ultimate vibration reduction rate of the gravel cushion fell between 20.44% and 31.33%. The gravel cushion is an excellent option for nuclear power plant foundations with high requirements for seismic isolation, provided that the required bearing capacity is satisfied.