1 September 2016 in Engineering Structures
1 June 2018 in Engineering Structures
1 May 2017 in Journal of Constructional Steel Research
1 September 2016 in Journal of Structural Engineering
Concrete-filled steel tubes (CFSTs) frequently are a more efficient and economical structural solution then conventional reinforced concrete and structural steel. For the same size member, CFSTs offer increased strength and stiffness as well as accelerated construction. CFSTs may be used for bridge columns that will yield under earthquake loading, but this requires robust connections capable of sustaining large cyclic loads. To facilitate accelerated bridge construction, precast cap beams and girders are commonly used. Although CFST column-to-foundation connections have been studied, CFST column-to-precast cap beam connections have not. This is the focus of this research study. In contrast to cast-in-place (CIP) components, precast pier cap connections require additional design considerations including construction methodology and limits on geometry. To investigate this connection an integrated analytical and experimental research program was performed. Initially, continuum finite-element methods ...
1 August 2022 in Earthquake Spectra
30 June 2017 in Bulletin of the New Zealand Society for Earthquake Engineering
Six buildings in the Wellington region and the upper South Island, instrumented as part of the GeoNet Building Instrumentation Programme, recorded strong motion data during the 2016 Kaikoura earthquake. The response of two of these buildings: the Bank of New Zealand (BNZ) Harbour Quays, and Ministry of Business, Innovation, and Employment (MBIE) buildings, are examined in detail. Their acceleration and displacement response was reconstructed from the recorded data, and their vibrational characteristics were examined by computing their frequency response functions. The location of the BNZ building in the CentrePort region on the Wellington waterfront, which experienced significant ground motion amplification in the 1–2 s period range due to site effects, resulted in the imposition of especially large demands on the building. The computed response of the two buildings are compared to the intensity of ground motions they experienced and the structural and nonstructural damage they suffered, in an effort to motivate the use of structural response data in the validation of performance objectives of building codes, structural modelling techniques, and fragility functions. Finally, the nature of challenges typically encountered in the interpretation of structural response data are highlighted.