Jean Chaoui

Jean Chaoui

Auto-generated profile, based on publicly available information

Jean Chaoui

Imascap, Plouzané, France

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2023 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
JSJoaquin Sanchez-Sotelo
Joaquin Sanchez-Sotelo
JBJulien Berhouet
Julien Berhouet
JCJean Chaoui
Jean Chaoui
MFMichael T Freehill
Michael T Freehill
PCPhilippe COLLIN
Philippe COLLIN
GAGeorge S. Athwal
George S. Athwal

1 January 2022 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
JWJean-David Werthel
Jean-David Werthel
FCFrançois Boux de Casson
François Boux de Casson
GWGilles Walch
Gilles Walch
PGPascal Gaudin
Pascal Gaudin
PMPhilipp Moroder
Philipp Moroder
VBValérie Burdin
Valérie Burdin

1 October 2021 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
MGMarc-Olivier GAUCI
Marc-Olivier GAUCI
GAGeorge S. Athwal
George S. Athwal
JSJoaquin Sanchez-Sotelo
Joaquin Sanchez-Sotelo
JCJean Chaoui
Jean Chaoui
MUManuel Urvoy
Manuel Urvoy
GWGilles Walch
Gilles Walch

18 February 2021 in Shoulder & Elbow
Verified
Journal Article
Closed access
PDF file
MGMarc-Olivier GAUCI
Marc-Olivier GAUCI
JCJean Chaoui
Jean Chaoui
JBJulien Berhouet
Julien Berhouet
AJAdrien Jacquot
Adrien Jacquot
GWGilles Walch
Gilles Walch
PBPascal Boileau
Pascal Boileau
Background: Early glenohumeral impingement leads to poor range of motion and notching in reverse shoulder arthroplasty. The aim was to find from planning software which implant configuration provides the best motions in reverse shoulder arthroplasty. Patients and Methods: Reverse shoulder arthroplasty planning (Glenosys) was made in 31 patients (12 men, 19 women, 76 ± 6 yo) and impingements were analyzed. Inlay (155°-inclined) and Onlay (145°-inclined) humeral designs were tested. Four configurations were tested for each shoulder: “INLAY”: non-lateralized glenoid-inlay humerus, “BIO-INLAY”: lateralized glenoid (BIO-RSA)-inlay humerus, “ONLAY”: non-lateralized glenoid-onlay humerus, and “BIO-ONLAY”: lateralized (BIO-RSA) glenoid-onlay humerus. Results: BIO-ONLAY and BIO-INLAY groups presented a significantly better result in all tested motion ( p < 0.001 for all tests). BIO-ONLAY allowed a significantly better external rotation, extension and adduction than BIO-INLAY with decreased impingements with the pilar. BIO-INLAY presented a significantly better abduction. In abduction, an abutment of the greater tuberosity against the acromion was associated with a lower range of motion ( p < 0.0001) and did not depend on the lateralization. Conclusion: Glenoid lateralization delays the glenohumeral impingement in reverse shoulder arthroplasty and gives the best rotations, adduction and extension when associated with neutral inclination and humeral 145° inclination. Greater tuberosity abutment has to be avoided in abduction and the Inlay design provides the best abduction.

1 August 2015 in IRBM
Verified
Journal Article
Closed access
MMM. Mayya
M. Mayya
SPS. Poltaretskyi
S. Poltaretskyi
CHC. Hamitouche
C. Hamitouche
JCJ. Chaoui
J. Chaoui

16 September 2021 in JSES International
Verified
Journal Article
Open access
William G BlakeneyWilliam G Blakeney
William G Blakeney
MUManuel Urvoy
Manuel Urvoy
JCJean Chaoui
Jean Chaoui
PRPatric Raiss
Patric Raiss
GAGeorge S. Athwal
George S. Athwal
GWGilles Walch
Gilles Walch
The purpose of this study was to develop novel three-dimensional (3D) measures of bone density from computed tomography (CT) scans and to compare them with validated two-dimensional (2D) radiographic assessments of bone density. Patient demographic data were also analyzed to see if there were any predictors of bone density (age, sex, etiology). The study group consisted of 290 consecutive patients undergoing primary shoulder arthroplasty surgery (total anatomic, reverse, and hemiarthroplasty). All underwent preoperative CT imaging. Three 3D CT measurements (metaphysis cancellous, metaphysis cortical, and proximal diaphysis) were developed and automated into software. The developed 3D measurements were compared with validated 2D measures (Tingart and Gianotti Index). Patient demographic data were correlated with these measurements. The difference between the size of the final sounder and of the final stem was calculated as Delta. There was moderately strong correlation between Tingart and Gianotti measures (0.674, P < .001), as well as between 3D metaphysis cancellous measurements and Tingart (0.645, P < .001). Decreased bone density was highly correlated with female sex. Tingart (area under the curve [AUC]: 0.87, 95% confidence interval [CI]: 0.82-0.91) and 3D metaphysis cancellous (AUC: 0.78, 95% CI: 0.72-0.84) had the highest correlation. These were significantly more than other measures of bone density (P < .01). Decreased bone density measured with Tingart also had moderate correlation with advanced age (AUC: 0.67, 95% CI: 0.6-0.73), but less so for etiology (AUC: 0.62, 95% CI: 0.55-0.69). The 3D metaphysis cancellous measure had lower correlation with age (AUC: 0.59, 95% CI: 0.52-0.66) and etiology (AUC: 0.59, 95% CI: 0.52-0.65). The highest correlation with Delta (the difference between the final sounder and the stem size) was with the 3D metaphysis cancellous measure (AUC: 0.67, 95% CI: 0.59-0.73), followed by Tingart (AUC: 0.647, 95% CI: 0.57-0.671). A multiple regression model to predict Delta demonstrated the stronger prediction using 3D metaphysis cancellous (analysis of variance F-ratio of 42.6, P < .001) than Tingart (35.9, P < .001). This study demonstrates that automated measures of bone density can be obtained from 3D CT scans. Of the three novel 3D measurements of bone density, the humeral metaphysis cancellous measurement was most correlated to the known 2D measures and most correlated to the intraoperative assessment of bone density (delta).