Sana Ullah

Sana Ullah

Auto-generated profile, based on publicly available information

Sana Ullah

Department of Electronic Engineering, Hanyang University, Seoul, South Korea

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2023 in IEEE Antennas and Propagation Magazine
Verified
Journal Article
Closed access
ABAbdul Basir
Abdul Basir
YCYoungdae Cho
Youngdae Cho
ISIzaz Ali Shah
Izaz Ali Shah
SHShahzeb Hayat
Shahzeb Hayat
SUSana Ullah
Sana Ullah
HYHyoungsuk Yoo
Hyoungsuk Yoo
This article for the “Bioelectromagnetics” column takes a deep dive into the field of wireless implants and ingestibles, with a focus on antenna design. The review discusses recent advances in implantable/ingestible antenna design, provides a protocol for the successful design of such antennas, and concludes with an overview of the wide range of real-world applications that may benefit from this research area.

24 July 2023 in IEEE Access
Verified
Journal Article
Open access
NANaeem Abbas
Naeem Abbas
SUSana Ullah
Sana Ullah
ZBZubair Bashir
Zubair Bashir
ABAbdul Basir
Abdul Basir
HYHyoungsuk Yoo
Hyoungsuk Yoo
The study proposes a small dual-band implantable antenna for brain-machine interface (BMI) working over industrial, scientific, and medical (915 MHz, 2.45 GHz) bands. The antenna’s flexibility and small size allow for easy integration into implantable devices, while its dual-band resonance enables power-efficient operation. Through parametric analysis and optimization, the antenna achieves miniaturization without compromising performance. Slitted ground and patch and shorting pins techniques are used to achieve dual-band operation with miniaturized sizes of the antenna and BMI device of 9.8 mm 3 and 420 mm 3 , respectively. For a practical scenario, a seven-layer brain model with different layers and a realistic head model were used to analyze the performance of the antenna in heterogeneous environments. The calculated maximum specific absorption rate (SAR) values satisfied the IEEE safety standards C95.1-1999 and C95.1-2005 for implantable medical devices if the maximum radiated powers are under 10.1 and 8.1 mW at 915 and 2450 MHz, respectively. To verify the simulated results, the fabricated prototype underwent testing with minced pork meat, yielding impressive impedance bandwidths of 165 MHz and 625 MHz. The measurements revealed significant gains of -28.3 dBi and -18.5 dBi at frequencies of 915 MHz and 2.4 GHz, respectively. These findings validate the accuracy of the simulations without any deviations. Moreover, the link budget analysis results suggested that the antenna system can transmit a signal of up to 10 m at a data rate of 100 kbps.

3 June 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
SUSana Ullah
Sana Ullah
MZMuhammad Zada
Muhammad Zada
ABAbdul Basir
Abdul Basir
HYHyoungsuk Yoo
Hyoungsuk Yoo
An elegant solution for the concurrent transmission of data and power is essential for implantable wireless magnetic resonance imaging (MRI). This paper presents a self-tuned open interior microcoil (MC) antenna with three useful operating bands of 300 (7 T), 400, and 920 MHz, for blood vessel imaging, data telemetry, and efficient wireless transmission of power, respectively. The proposed open interior MC antenna contains two mirrorlike arms with diameters and lengths of 2.4 mm and 9.8 mm, respectively, to avoid blood flow blockage. To wirelessly show LED glow on a saline based phantom, the MC was fabricated on a flexible polyimide material and combined with a miniaturized rectifier and a micro-LED. Using a path gain, the power transfer efficiency (PTE) of the MC rotation was also analyzed. Additionally, the PTE was calculated for a range of distances between 25 and 60 mm, and a −27.1 dB PTE attained at a distance of of 30 mm. Based on the recommendations of the International Commission on Non-Ionizing Radiation Protection for human brain safety when exposed to radio-frequencies from external transmitter, a specific absorption rate analysis was analyzed. Measurements of the s-parameters were noted using a saline solution and blood vessel model to imitate a realistic human head. They were found to correlate reasonably with the simulated results.

2 November 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
SHShahzeb Hayat
Shahzeb Hayat
SUSana Ullah
Sana Ullah
ABAbdul Basir
Abdul Basir
HYHyoungsuk Yoo
Hyoungsuk Yoo
Dental magnetic resonance imaging (MRI) has been improved through the development of an intraoral antenna that increases the signal-to-noise ratio and image quality. This study aimed to design a fully flexible coaxial dipole antenna for intraoral applications at 3 T. The dipole design is characterized by its open distal end, which allows for a lack of restriction on the movement of the tongue, and also offers an increased depth of sensitivity that allows for dental roots. The finite element method and finite-difference time-domain simulations were used to optimize the antenna performance and identify the optimum gaps in the shield that ensure a uniform current distribution at the desired frequency band. Finally, a fabricated prototype was evaluated in minced pork to measure the reflection coefficient in open- and closed-mouth scenarios. The optimal configurations were determined with gaps on both sides of the fully flexible dipole antenna at small and large curvatures. Furthermore, the implementation of the dipole antenna has led to improvement in the B + 1 field homogeneity, resulting in higher transmit and specific absorption rate efficiency. In addition, the MR images obtained by the proposed dental coil exhibited high sensitivity of the dental roots, teeth, and surrounding mouth. Finally, safety considerations were considered when analyzing the performance of the intraoral antenna under MRI. A novel intraoral flexible antenna and its advantages are described to overcome the challenges associated with intraoral RF coils.

20 October 2020 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
SUSana Ullah
Sana Ullah
HYHyoungsuk Yoo
Hyoungsuk Yoo
This paper presents rectangular and circular intravascular receive-only (Rx) open interior micro-coils (MCs) for blood-vessel and brain-aneurysm imaging with two different magnetic resonance imaging (MRI) frequencies (128 MHz and 298 MHz for field strengths 3 T and 7 T, respectively). The proposed Rx MCs have a miniature volume of 4.92 mm3. They offer a wider bandwidth, homogenous radio frequency (RF) receptivity, a high signal-to-noise ratio, and better vessel imaging than that offered by state-of-the-art MCs. Additionally, they have open interiors that enable uninterrupted blood flow during MRI scanning and reduce motion artifacts. The proposed MCs were used to mimic different blood vessels of the brain, heart, neck, and kidneys in a realistic human voxel-based Duke model. We compared the reception efficiency (Rx,eff) and the sum of B1- strengths (i.e., ΣB1-) in the region of interest (ROI) for the combined approach involving the birdcage (BC)/surface coil and the MC for various coil arrangements. The proposed MCs were fabricated and integrated with the 3D-printed blood-vessel model. The simulation results indicate that the proposed MCs achieved improvements of 72% and 75% in ΣB1- and Rx,eff, respectively, in the selected ROI (the blood vessel). Moreover, the MR images obtained by the proposed MCs exhibited high sensitivity of the blood signal and offered selective imaging of the arterial walls. According to the results, the proposed Rx MCs can be applied to perform intravascular imaging of smaller blood vessels.

22 October 2021 in IEEE Access
Verified
Journal Article
Open access
SUSana Ullah
Sana Ullah
HYHyoungsuk Yoo
Hyoungsuk Yoo
In a multi-element microstrip transmission line (MTL) transmit array coil, the transmit field ( $B_{1}^{+}$ ) distribution is inhomogeneous due to its standing-wave nature, and the interference effects can severely degrade the $B_{1}^{+}$ and imaging. Therefore, to improve the homogeneity and strength of $B_{1}^{+}$ , this study focuses on the development of a multi-element MTL transmit array coil integrated with a dielectric liner (DL) material. Furthermore, the transmission efficiency ( $T_{x,eff}$ ) is improved in the head region. An eight-element MTL transmits array head coil is investigated using thinner DLs, and the optimized dimensions of the DL are found from its resonant mode at 7 Tesla (T). Simulations and measurements are performed with an MTL transmit array coil at 7 T, and the performance is analyzed for the DL positions and dimensions. Remarkably, the proposed DLs-integrated transmit array coil system offered significant improvements in the $T_{x,eff}$ at different DLs positions. Compared to the case without the DL, the $T_{x,eff}$ is improved by 9% (DL close to the head model), 15% (DL at center), and 39% (DL close to the RF coil). Interestingly, the DL acts as an efficiency tuner element exhibiting a 9% to 39% $T_{x,eff}$ tuning range of improvement. In addition, the RF-shimming technique improves the $B_{1}^{+}$ homogeneity and $T_{x,eff}$ of the coil with DLs by 21% and 42%, respectively, compared to the case without the DL. Moreover, the specific absorption rate (SAR) analysis of the MTL transmit array coil with the DLs is performed. The peak 10g-averaged SAR is reduced from 3.1 W/kg to 2.13 W/kg in the head using DLs and RF-shimming technique. Finally, we used the bench measurement setup to obtain the measured magnetic field. The proposed work exhibits salient features with a smaller DL size and multi-element MTL transmit array coil than other proposed works.