Sofia Johansson

Sofia Johansson

Auto-generated profile, based on publicly available information

Sofia Johansson

Division of Biomedical Engineering, Department of Materials Science and Engineering, Science for Life Laboratory, Uppsala University, Uppsala, Sweden

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2021 in ACS Biomaterials Science & Engineering
Verified
Journal Article
Open access
SFStefanie Fuchs
Stefanie Fuchs
SJSofia Johansson
Sofia Johansson
ATAnders Ø. Tjell
Anders Ø. Tjell
GWGabriel Werr
Gabriel Werr
TMTorsten Mayr
Torsten Mayr
MTMaria Tenje
Maria Tenje
Organ-on-chip systems are promising new in vitro research tools in medical, pharmaceutical, and biological research. Their main benefit, compared to standard cell culture platforms, lies in the improved in vivo resemblance of the cell culture environment. A critical aspect of these systems is the ability to monitor both the cell culture conditions and biological responses of the cultured cells, such as proliferation and differentiation rates, release of signaling molecules, and metabolic activity. Today, this is mostly done using microscopy techniques and off-chip analytical techniques and assays. Integrating in situ analysis methods on-chip enables improved time resolution, continuous measurements, and a faster read-out; hence, more information can be obtained from the developed organ and disease models. Integrated electrical, electrochemical, and optical sensors have been developed and used for chemical analysis in lab-on-a-chip systems for many years, and recently some of these sensing principles have started to find use in organ-on-chip systems as well. This perspective review describes the basic sensing principles, sensor fabrication, and sensor integration in organ-on-chip systems. The review also presents the current state of the art of integrated sensors and discusses future potential. We bring a technological perspective, with the aim of introducing in-line sensing and its promise to advance organ-on-chip systems and the challenges that lie in the integration to researchers without expertise in sensor technology.

17 March 2021 in Cardiovascular Research
Verified
Journal Article
Open access
PDF file
VPValentina Paloschi
Valentina Paloschi
MSMaria Sabater-Lleal
Maria Sabater-Lleal
HMHeleen Middelkamp
Heleen Middelkamp
AVAisen Vivas
Aisen Vivas
SJSofia Johansson
Sofia Johansson
LMLars Maegdefessel
Lars Maegdefessel
The development of organs-on-chip (OoC) has revolutionized in vitro cell-culture experiments by allowing a better mimicry of human physiology and pathophysiology that has consequently led researchers to gain more meaningful insights into disease mechanisms. Several models of hearts-on-chips and vessels-on-chips have been demonstrated to recapitulate fundamental aspects of the human cardiovascular system in the recent past. These 2D and 3D systems include synchronized beating cardiomyocytes in hearts-on-chips and vessels-on-chips with layer-based structures and the inclusion of physiological and pathological shear stress conditions. The opportunities to discover novel targets and to perform drug testing with chip-based platforms have substantially enhanced, thanks to the utilization of patient-derived cells and precise control of their microenvironment. These organ models will provide an important asset for future approaches to personalized cardiovascular medicine and improved patient care. However, certain technical and biological challenges remain, making the global utilization of OoCs to tackle unanswered questions in cardiovascular science still rather challenging. This review article aims to introduce and summarize published work on hearts- and vessels-on chips but also to provide an outlook and perspective on how these advanced in vitro systems can be used to tailor disease models with patient-specific characteristics.

10 October 2023 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
NKNüzhet Inci Kilic
Nüzhet Inci Kilic
Giovanni Marco SaladinoGiovanni Marco Saladino
Giovanni Marco Saladino
SJSofia Johansson
Sofia Johansson
RSRickard Shen
Rickard Shen
CMCacie McDorman
Cacie McDorman
SJStefan Johansson
Stefan Johansson
Two-photon polymerization (2PP) is an efficient technique to achieve high-resolution, three-dimensional (3D)-printed complex structures. However, it is restricted to photocurable monomer combinations, thus presenting constraints when aiming at attaining functionally active resist formulations and structures. In this context, metal nanoparticle (NP) integration as an additive can enable functionality and pave the way to more dedicated applications. Challenges lay on the maximum NP concentrations that can be incorporated into photocurable resist formulations due to the laser-triggered interactions, which primarily originate from laser scattering and absorption, as well as the limited dispersibility threshold. In this study, we propose an approach to address these two constraints by integrating metallic Rh NPs formed ex situ, purposely designed for this scope. The absence of surface plasmon resonance (SPR) within the visible and near-infrared spectra, coupled with the limited absorption value measured at the laser operating wavelength (780 nm), significantly limits the laser-induced interactions. Moreover, the dispersibility threshold is increased by engineering the NP surface to be compatible with the photocurable resin, permitting us to achieve concentrations of up to 2 wt %, which, to our knowledge, is significantly higher than the previously reported limit (or threshold) for embedded metal NPs. Another distinctive advantage of employing Rh NPs is their role as promising contrast agents for X-ray fluorescence (XRF) bioimaging. We demonstrated the presence of Rh NPs within the whole 2PP-printed structure and emphasized the potential use of NP-loaded 3D-printed nanostructures for medical devices.

24 January 2024 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
MLMara Lucchetti
Mara Lucchetti
GWGabriel Werr
Gabriel Werr
SJSofia Johansson
Sofia Johansson
LBLaurent Barbe
Laurent Barbe
LGLéa Grandmougin
Léa Grandmougin
MTMaria Tenje
Maria Tenje
In healthy individuals, the intestinal epithelium forms a tight barrier to prevent gut bacteria from reaching blood circulation. To study the effect of probiotics, dietary compounds and drugs on gut barrier formation and disruption, human gut epithelial and bacterial cells can be cocultured in an in vitro model called the human microbial crosstalk (HuMiX) gut-on-a-chip system. Here, we present the design, fabrication and integration of thin-film electrodes into the HuMiX platform to measure transepithelial electrical resistance (TEER) as a direct readout on barrier tightness in real-time. As various aspects of the HuMiX platform have already been set in their design, such as multiple compressible layers, uneven surfaces and nontransparent materials, a novel fabrication method was developed whereby thin-film metal electrodes were first deposited on flexible substrates and sequentially integrated with the HuMiX system via a transfer-tape approach. Moreover, to measure localized TEER along the cell culture chamber, we integrated multiple electrodes that were connected to an impedance analyzer via a multiplexer. We further developed a dynamic normalization method because the active measurement area depends on the measured TEER levels. The fabrication process and system setup can be applicable to other barrier-on-chip systems. As a proof-of-concept, we measured the barrier formation of a cancerous Caco-2 cell line in real-time, which was mapped at four spatially separated positions along the HuMiX culture area.

23 March 2021 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MAMartin Andersson
Martin Andersson
SJSofia Johansson
Sofia Johansson
HBHenrik Bergman
Henrik Bergman
LXLinhong Xiao
Linhong Xiao
LBLars Behrendt
Lars Behrendt
MTMaria Tenje
Maria Tenje
This work describes a programmable heat-stage compatible with in situ microscopy for the accurate provision of spatiotemporally defined temperatures to different microfluidic devices. The heat-stage comprises an array of integrated thin-film Joule heaters and resistance temperature detectors (RTDs). External programming of the heat-stage is provided by a custom software program connected to temperature controllers and heater–sensor pairs. Biologically relevant (20–40 °C) temperature profiles can be supplied to cells within microfluidic devices as spatial gradients (0.5–1.5 °C mm−1) or in a time-varying approach via e.g. step-wise or sinusoidally varying profiles with negligible temperature over-shoot. Demonstration of the device is achieved by exposing two strains of the coral symbiont Symbiodinium to different temperature profiles while monitoring their single-cell photophysiology via chlorophyll fluorometry. This revealed that photophysiological responses to temperature depended on the exposure duration, exposure magnitude and strain background. Moreover, thermal dose analysis suggested that cell acclimatisation occurs under longer temperature (6 h) exposures but not under shorter temperature exposures (15 min). As the thermal sensitivity of Symbiodinium mediates the thermal tolerance in corals, our versatile technology now provides unique possibilities to research this interdependency at single cell resolution. Our results also show the potential of this heat-stage for further applications in fields such as biotechnology and ecotoxicology.

9 January 2014 in IEEE Electron Device Letters
Verified
Journal Article
Open access
GRGuntrade Roll
Guntrade Roll
ELErik Lind
Erik Lind
MEMikael Egard
Mikael Egard
SJSofia Johansson
Sofia Johansson
LFLars Ohlsson Fhager
Lars Ohlsson Fhager
LWLars-Erik Wernersson
Lars-Erik Wernersson
A complete reliability study of the DC and RF characteristics for InGaAs nMOSFETs with Al2O3/HfO2 dielectric is presented. The main stress variation at high frequencies is related to a threshold voltage shift, whereas no decrease is found in the maximum of the cutoff frequency and RF transconductance. Constant gate stress leads to a charge build up causing a threshold voltage shift. Furthermore, electron trapping at the drain side degrades the performance after hot carrier stress. The maximum DC transconductance is reduced following constant gate bias stress, by an increase in charge trapping at border defects. These border defects at the channel/high-κ interface are filled by cold carrier trapping when the transistor is turned on, whereas they do not respond at high frequencies.