7 February 2022 in IEEE Access
Electrochemical cells are complicated energy storage systems with nonlinear voltage dynamics. There is a need for accurate dynamic modeling of the battery system to predict its behavior over time when discharging. The study conducted in this paper developed an intuitive model for electrochemical cells based on a simple mechanical analogy. A three-degree-of-freedom, spring-mass-damper system was decomposed into modal coordinates that represent the overall discharge, mass transport, and double-layer effect of the electrochemical cell. The developed model was experimentally demonstrated through pulsed discharge tests of commercially available lithium-ion and nickel metal hydride cells. The modal parameters of the natural frequency and damping ratio for each mode were determined by numerically minimizing the error in the time responses. Additionally, the mechanical analog was applied to two datasets developed by the Center for Advanced Life Cycle Engineering (CALCE). The first dataset was used to optimize the modal parameters whereas the second dataset was utilized to validate the tuned parameters. It was found that the modal representation of the mechanical analog could accurately predict the time-response dynamics of all the cells considered. Additionally, by considering the discharge modal coordinate, the open-circuit voltage was determined and validated to that measured experimentally from the voltage relaxation peaks.
9 May 2022 in IEEE Access
Lithium-ion batteries have complicated dynamics and temperature behavior. In this paper, a dynamic system previously developed to characterize the voltage response was extended to estimate the heat generation rate due to the electrochemical reactions that a battery undergoes as being discharged. The dynamic system based on a modally decomposed three-degree-of-freedom, spring-mass-damper analogy was used to estimate the cells terminal voltage, open-circuit voltage and the mass transfer and boundary layer effects. The modal parameters were determined by minimizing the error between the experimental and simulated time responses. Then, these estimated parameters were coupled with a lumped thermal model to predict the temperature profiles of two cylindrical lithium-ion batteries. To capture the dynamic voltage and temperature responses, hybrid pulse power characterization (HPPC) tests were conducted with thermocouples. It was found that the dynamic model was able to accurately estimate the nonlinear dynamics of the batteries; therefore, the electrochemical heat generation rate was successfully able predict the surface temperature profile at 1C and 2C discharge rates.
1 January 2026 in International Journal of Energy Research
This study presents a 28‐case computational fluid dynamics (CFD) parametric investigation of Al 2 O 3 /water and Al 2 O 3 –TiO 2 /water hybrid nanofluid cooling for an LG Chem 15 Ah lithium‐ion pouch cell subjected to a prescribed steady thermal load of 277.5 W. The imposed load is used as a severe thermal‐stress condition for coolant comparison and is not interpreted as the electrochemical heat generated by the cell at a specific C‐rate. Four Reynolds numbers (Re = 2300–10,000) and three particle volume fractions (1%, 2%, and 4%) were examined in ANSYS Fluent. The Re = 2300 cases were solved as laminar, whereas Re = 4434, 7000, and 10,000 employed the realizable k–ε model with enhanced wall treatment. Nanofluid properties were estimated using a single‐phase effective‐property approach with Maxwell thermal conductivity and Brinkman viscosity correlations. The battery‐side thermal model was compared with FLIR thermography at 32 W under natural convection; this comparison supports the hotspot location and cell‐level temperature pattern but is not presented as forced‐convection nanofluid validation. Reynolds number remained the dominant control parameter. At Re = 2300, the 4% hybrid nanofluid reduced the maximum hotspot temperature by 8.1°C relative to water and increased the bulk‐temperature‐based heat‐transfer coefficient by ~13.1%. For the turbulent cases, all nanofluids produced PEC values below unity, while at Re = 2300 the PEC values were effectively unity (0.997–1.003). Above Re = 7000, the predicted temperature advantage of nanofluid addition decreased below 0.9°C. The results indicate that hybrid nanofluids primarily provide incremental hotspot reduction at low‐to‐moderate Reynolds numbers, whereas water remains the stronger thermal‐hydraulic baseline over the turbulent range.