ESC (Escitalopram) and ETZ (Etizolam) are essential anti-anxiety medications. This research suggests employing a Green Analytical Quality by Design (AQbD) based HPLC technique to determine ESC and ETZ are environmentally friendly. According to literature, there is currently no published article by this method. Using Phenomenex column C18 containing ethanol and phosphate buffer (60:40 percent v/v) and the flow rate is fixed to be 1 mL/ min, and the detection was carried out at 254 nm the proposed approach can separate ESC and ETZ and their degradation products. Retention times of ESC and ETZ were found to be 3.5 and 6.5 min respectively. This approach was verified and demonstrated linearity ranges from 5–30 μg/mL for ESC, 2–12 μg/mL for ETZ, accuracy, repeatability, and selectivity, with R2 values were 0.9975 and 0.9987 for ESC and ETZ, respectively. The novel method was also evaluated using four different approaches,including other assessment methods: NEMI, GAPI, AGMS, AGREE and it was found to been environment friendly. Based on our results, HPLC techniques with the Green Analytical Performances by the QbD technique for evaluating stability of the drug might be benefit in the development of novel pharmaceutical drugs such as ESC and ETZ. GRAPHICAL ABSTRACT
26 October 2023 in Journal of Liquid Chromatography & Related Technologies
The two chemical components Escitalopram (ESC) and Etizolam (ETZ) are beneficial for the health of individuals because it helps to treat anxiety. The study mainly illustrated that a green approach is essential in the medical sector with the help of “Green Analytical quality by design”. According to AQbD, the techniques of HPTLC have become eco-friendly, and decided to use “ESC” and “ETZ”. Hence, ethanol and phosphate buffer pH 3.5 adjusted with 1% “orthophosphoric acid”. After the retardation factor, the product ESC was found at 0.34 min and ETZ was found at 0.53 min. The linearity of ETZ the range varies from 300 to 1800 μg mL−1 and for ESC it varies from 100 to 600 μg mL−1. The validation parameter of R2 Values ranged from 0.9997 to 0.9994 for both ESC and ETZ. The study also demonstrated that different other methods were also useful for the medical sector to make it more convenient and eco-friendly. Some of those approaches are “GAPI”, “AGMS”, “NEMI”, and “AGREE”. The outcome of the study helped to find that the technique “HPTLC” is a green analytic design that helps to maintain the stability of the medicine and it was also approved as a quality design and also a novel approach in the pharmaceutical sector.