Amina K. Stoddart

Amina K. Stoddart

Auto-generated profile, based on publicly available information

Amina K. Stoddart

Centre for Water Resources Studies, Department of Civil & Resource Engineering, Dalhousie University, 1360 Barrington Street, Halifax, Nova Scotia B3H 4R2, Canada

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2021 in Environmental Science: Water Research & Technology
Verified
Journal Article
Open access
PDF file
EHE. K. Hayes
E. K. Hayes
CSC. L. Sweeney
C. L. Sweeney
LAL. E. Anderson
L. E. Anderson
BLB. Li
B. Li
GEG. B. Erjavec
G. B. Erjavec
GGG. A. Gagnon
G. A. Gagnon
The overall objective of this work was to develop a simple and effective passive sampling protocol for the detection of SARS-CoV-2 in sewer catchments at targeted institutional-level sampling sites in a region of low COVID-19 prevalence. We developed a new 3D-printed sampling cage and assessed four commercially-available materials (cotton gauze, cotton cheesecloth, cellulose sponges, and electronegative filters) for RNA adsorption in the cage. We determined that cheesecloth and electronegative filters provided an effective approach for collecting and measuring SARS-CoV-2 in wastewater. We also compared the performance of three elution mixtures (a commercially-available lysis buffer, a Tween®20-based buffer, and a 1:1 acetonitrile:water mixture) for detection of heat-inactivated SARS-CoV-2 reference material (HI-SCV-2) spiked into municipal wastewater at 1.0 × 103 genomic units per millilitre (GU mL−1). The highest mean RNA concentrations were achieved using the cheesecloth (7.0 × 104 ± 3.7 × 104 GU per eluate) and electronegative filters (2.3 × 104 ± 2.5 × 104 GU per eluate) in combination with the Tween®20-based buffer with positive detections in all three biological replicates for both material types. We deployed passive samplers at two sewer catchments (locations A and B) to compare the performance of each passive sampler material type in the field. Over 15 sampling events at each site, we demonstrated that both cheesecloth (location A) and electronegative filters (location B) coupled with a Tween®20-based elution technique could be utilized for the reliable detection of SARS-CoV-2. These results have demonstrated a quick and effective passive sampling approach for SARS-CoV-2 detection in targeted locations in wastewater collection systems, which may have long-term applicability as global vaccination programs evolve.

10 May 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SMSean A. MacIsaac
Sean A. MacIsaac
KRKyle D. Rauch
Kyle D. Rauch
TPTaylor Prest
Taylor Prest
RSRichard M. Simons
Richard M. Simons
GGGraham A. Gagnon
Graham A. Gagnon
ASAmina K. Stoddart
Amina K. Stoddart
Ultraviolet (UV) disinfection has been incorporated into both drinking water and wastewater treatment processes for several decades; however, it comes with negative environmental consequences such as high energy demands and the use of mercury. Understanding how to scale and build climate responsive technologies is key in fulfilling the intersection of UN Sustainable Development Goals 6 and 13. One technology that addresses the drawbacks of conventional wastewater UV disinfection systems, while providing a climate responsive solution, is UV light emitting diodes (LEDs). The objective of this study was to compare performance of bench-scale 280 nm UV LEDs to bench-scale low pressure (LP) lamps and full-scale UV treated wastewater samples. Results from the study demonstrated that the UV LED system provides a robust treatment that outperformed LP systems at the bench-scale. A comparison of relative energy consumptions of the UV LED system at 20 mJ cm−2 and LP system at 30 and 40 mJ cm−2 was completed. Based on current projections for wall plug efficiencies (WPE) of UV LED it is expected that the energy consumption of LED reactors will be on par or lower compared to the LP systems by 2025. This study determined that, at a WPE of 20%, the equivalent UV LED system would lead to a 24.6% and 43.4% reduction in power consumption for the 30 and 40 mJ cm−2 scenarios, respectively.

21 January 2022 in ACS ES&T Water
Verified
Journal Article
Open access
EHEmalie K. Hayes
Emalie K. Hayes
CSCrystal L. Sweeney
Crystal L. Sweeney
Megan FullerMegan Fuller
Megan Fuller
GEGenevieve B. Erjavec
Genevieve B. Erjavec
ASAmina K. Stoddart
Amina K. Stoddart
GGGraham A. Gagnon
Graham A. Gagnon
In developing an effective monitoring program for the wastewater surveillance of SARS-CoV-2 ribonucleic acid (RNA), the importance of sampling methodology is paramount. Passive sampling has been shown to be an effective tool to detect SARS-CoV-2 RNA in wastewater. However, the adsorption characteristics of SARS-CoV-2 RNA on passive sampling material are not well-understood, which further obscures the relationship between wastewater surveillance and community infection. In this work, adsorption kinetics and equilibrium characteristics were evaluated using batch-adsorption experiments for heat-inactivated SARS-CoV-2 (HI-SCV-2) adsorption to electronegative filters. Equilibrium isotherms were assessed or a range of total suspended solids (TSS) concentrations (118, 265, and 497 mg L–1) in wastewater, and a modeled qmax of 7 × 103 GU cm–2 was found. Surrogate adsorption kinetics followed a pseudo-first-order model in wastewater with maximum concentrations achieved within 24 h. In both field and isotherm experiments, equilibrium behavior and viral recovery were found to be associated with wastewater and eluate TSS. On the basis of the results of this study, we recommend a standard deployment duration of 24–48 h and the inclusion of eluate TSS measurement to assess the likelihood of solids inhibition during analysis.

9 July 2024 in Water Research X
Verified
Journal Article
Open access
SMSean A MacIsaac
Sean A MacIsaac
BRBailey Reid
Bailey Reid
COCarolina Ontiveros
Carolina Ontiveros
KLKarl G Linden
Karl G Linden
ASAmina K Stoddart
Amina K Stoddart
GGGraham A Gagnon
Graham A Gagnon
The world's first full-scale, 280 nm UV LED reactor for wastewater disinfection was tested at flows of 545 and 817 m3 day-1. The system achieved a > 3 average log reduction of total coliform at 545 m3 day-1 and the 817 m3 day-1 flow rate achieved over a > 2.5 average log reduction for all operational conditions. The delivered fluence of the full-scale system ranged from 28 to 148 mJ cm-2 and aligns with a UV auditing study that was conducted prior to the installation of the wastewater reactor. These results benchmark the performance that can be achieved by UV LED disinfection and further connect bench-scale disinfection results with full-scale performance. The approach established in this manuscript provides a novel tool for utilities when considering emerging UV disinfection technologies. In summary, this study establishes that UV LEDs are an effective wastewater disinfectant at-scale and are comparable to conventional low-pressure UV systems. This is the first instance where the efficacy of UV LEDs for municipal wastewater disinfection has been demonstrated using a large-scale installation at a functioning wastewater facility.

1 December 2021 in Water Research
Verified
Journal Article
Closed access
NMN.E. McCormick
N.E. McCormick
MEM. Earle
M. Earle
CHC. Ha
C. Ha
LHL. Hakes
L. Hakes
AEA. Evans
A. Evans
GGG.A. Gagnon
G.A. Gagnon

30 September 2022 in Journal of Water Process Engineering
Verified
Journal Article
Open access
KRKyle D. Rauch
Kyle D. Rauch
SMSean A. MacIsaac
Sean A. MacIsaac
ASAmina K. Stoddart
Amina K. Stoddart
GGGraham A. Gagnon
Graham A. Gagnon