Kyle D. Rauch

Kyle D. Rauch

Auto-generated profile, based on publicly available information

Kyle D. Rauch

Center for Water Resources Studies Dalhousie University Halifax Nova Scotia Canada

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Water Research
Verified
Journal Article
Closed access
SGStephanie L. Gora
Stephanie L. Gora
KRKyle D. Rauch
Kyle D. Rauch
COC. Carolina Ontiveros
C. Carolina Ontiveros
ASAmina K. Stoddart
Amina K. Stoddart
GGGraham A. Gagnon
Graham A. Gagnon

10 May 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SMSean A. MacIsaac
Sean A. MacIsaac
KRKyle D. Rauch
Kyle D. Rauch
TPTaylor Prest
Taylor Prest
RSRichard M. Simons
Richard M. Simons
GGGraham A. Gagnon
Graham A. Gagnon
ASAmina K. Stoddart
Amina K. Stoddart
Ultraviolet (UV) disinfection has been incorporated into both drinking water and wastewater treatment processes for several decades; however, it comes with negative environmental consequences such as high energy demands and the use of mercury. Understanding how to scale and build climate responsive technologies is key in fulfilling the intersection of UN Sustainable Development Goals 6 and 13. One technology that addresses the drawbacks of conventional wastewater UV disinfection systems, while providing a climate responsive solution, is UV light emitting diodes (LEDs). The objective of this study was to compare performance of bench-scale 280 nm UV LEDs to bench-scale low pressure (LP) lamps and full-scale UV treated wastewater samples. Results from the study demonstrated that the UV LED system provides a robust treatment that outperformed LP systems at the bench-scale. A comparison of relative energy consumptions of the UV LED system at 20 mJ cm−2 and LP system at 30 and 40 mJ cm−2 was completed. Based on current projections for wall plug efficiencies (WPE) of UV LED it is expected that the energy consumption of LED reactors will be on par or lower compared to the LP systems by 2025. This study determined that, at a WPE of 20%, the equivalent UV LED system would lead to a 24.6% and 43.4% reduction in power consumption for the 30 and 40 mJ cm−2 scenarios, respectively.

30 October 2024 in Water Research X
Verified
Journal Article
Open access
KRKyle D. Rauch
Kyle D. Rauch
SMSean A. MacIsaac
Sean A. MacIsaac
BRBailey Reid
Bailey Reid
TMToni J. Mullin
Toni J. Mullin
AAAriel Atkinson
Ariel Atkinson
GGGraham A. Gagnon
Graham A. Gagnon
• The power output of UV LEDs has increased by 139x since 2010. • Continuity in UV LED experimental setups is key comparing studies and determining action spectra for different microbes. • Further improvements of UV LED efficiency will enable more use cases for the technology. • UV LEDs have found several niches in drinking water treatment and are beginning to be used in wastewater applications.

18 November 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KRKyle D. Rauch
Kyle D. Rauch
JBJessica L. Bennett
Jessica L. Bennett
ASAmina K. Stoddart
Amina K. Stoddart
GGGraham A. Gagnon
Graham A. Gagnon
Aeromonas salmonicida and Yersinia ruckeri are common pathogenic bacteria that impact salmonid aquaculture. Although vaccinations are available against both organisms, large-scale vaccination efforts can be expensive, cumbersome, and are not always reliable. Alternatively, these pathogens have been effectively inactivated using UV radiation from mercury-based systems. These systems are energy intensive and fragile which currently limits their use to closed and semi-closed production systems. UV light emitting diodes (UV LEDs) have recently emerged as a novel alternative to traditional mercury-based treatment. UV LEDs have durable housing, a relatively low energy draw, can be powered by a battery source and are adaptable to challenging environments. This study examined the effectiveness of three UV LED wavelengths for disinfection of A. salmonicida and Y. ruckeri in pure culture and resuspended in a wastewater matrix. All tested UV LEDs were effective in disinfecting both organisms. 267 and 279 nm wavelengths outperformed 255 nm disinfection in both test matrices. Particulate matter from wastewater reduced the upper limit of treatment for A. salmonicida but results still indicated that all wavelengths were effective for disinfection in a challenging matrix. This study represents the first use of UV LEDs for disinfection of A. salmonicida and Y. ruckeri and provides impact to aquaculture producers looking to implement novel technologies for disease control.

1 November 2023 in ACS ES&T Water
Verified
Journal Article
Open access
JLJaser Lara de Larrea
Jaser Lara de Larrea
SMSean A. MacIsaac
Sean A. MacIsaac
KRKyle D. Rauch
Kyle D. Rauch
ASAmina K. Stoddart
Amina K. Stoddart
GGGraham A. Gagnon
Graham A. Gagnon
This study assesses the efficacy of ultraviolet light-emitting diodes (UV LEDs) for deactivating Legionella pneumophila (pure culture) and Pseudomonas fluorescens (pure culture and biofilms) on relevant drinking water distribution system surfaces (cast iron and stainless steel). UV LED treatment at 280 nm demonstrated superior performance compared to that at 365 nm, achieving a 4.8 log reduction value (LRV) for P. fluorescens pure cultures and, for biofilms, 4.02 LRV for stainless steel and 2.96 LRV for cast iron at 280 nm. Conversely, the results were less effective at 365 nm, with suspected photolytic reactions on cast iron. Quantification of L. pneumophila yielded varying results: 4 LRV using standard plate counts, 1.8 LRV with Legiolert, and 1 LRV with quantitative polymerase chain reaction at 280 nm, while the results were less than 1.5 LRV at 365 nm. This study provides insights into managing opportunistic pathogens and biofilms, emphasizing the need for improved quantification tools to better assess treatment efficacy.

7 September 2018 in Ozone: Science & Engineering
Verified
Journal Article
Closed access
KRKyle D. Rauch
Kyle D. Rauch
AMAllison L. Mackie
Allison L. Mackie
BMBrian Middleton
Brian Middleton
XXXuesong Xie
Xuesong Xie
GGGraham A. Gagnon
Graham A. Gagnon
A biomass recovery method was developed to monitor UV disinfection efficacy using adenosine triphosphate (ATP). Typically, disinfection monitoring at wastewater treatment facilities (WWTFs) involves quantifying fecal and total coliforms or colony forming units, the results of which take a minimum of 24 h to produce. ATP quantification immediately before and after UV treatment, which takes only minutes, shows little reduction and often an increase in the microbial population since UV irradiation results in cells that are viable (i.e., still producing ATP) but not culturable. To overcome this, our biomass recovery method incorporates an incubation step to encourage life cycling of microbes. Average log reductions in cellular ATP (cATP) were found to be −0.28 ± 0.19, −0.011 ± 0.153, −0.17 ± 0.32, and 0.065 ± 0.074 using direct ATP measurements on UV-treated samples from WWTFs A, B, C, and D, respectively, while those using the recovery method were correspondingly 0.17 ± 0.34, 1.8 ± 0.8, 0.20 ± 0.35, and 0.72 ± 0.26. The response of the biomass recovery-ATP method indicated a significant direct correlation to the microbial population reduction observed in heterotrophic plate count (HPC) and Colilert® methods using both pure Escherichia coli culture and secondary municipal wastewater effluent.