10 February 2017 in Magnetic Resonance in Medicine
Purpose: To demonstrate the interchangeable neck shape–specific (NSS) coil concept that supplements standard commercial spine and head/neck coils to provide simultaneous high‐resolution (hi‐res) head/neck imaging with high signal‐to‐noise ratio (SNR).Methods: Two NSS coils were constructed on formers designed to fit two different neck shapes. A 7‐channel (7ch) ladder array was constructed on a medium neck former, and a 9‐channel (9ch) ladder array was constructed on large neck former. Both coils were interchangeable with the same preamp housing.Results: The 7ch and 9ch coils demonstrate SNR gains of approximately 4 times and 3 times over the Siemens 20‐channel head/neck coil in the carotid arteries of our volunteers, respectively. Coupling between the Siemens 32‐channel spine coil, Siemens 20‐channel head/neck coil, and the NSS coils was negligible, allowing for simultaneous hi‐res head/neck imaging with high SNR.Conclusions: This study demonstrates that supplementing existing commercial spine and head/neck coils with an NSS coil allows uniform simultaneous hi‐res imaging with high SNR in the anterior neck, while maintaining SNR of the commercial coil in the head and posterior neck. Magn Reson Med 78:2460–2468, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
22 July 2024 in Journal of Magnetic Resonance Imaging
Background: Conventional liver magnetic resonance elastography (MRE) requires breath‐holding (BH) to avoid motion artifacts, which is challenging for children. While radial free‐breathing (FB)‐MRE is an alternative for quantifying liver stiffness (LS), previous methods had limitations of long scan times, acquiring two slices in 5 minutes, and not resolving motion during reconstruction.Purpose: To reduce FB‐MRE scan time to 4 minutes for four slices and to investigate the impact of self‐gated (SG) motion compensation on FB‐MRE LS quantification in terms of agreement, intrasession repeatability, and technical quality compared to conventional BH‐MRE.Study Type: Prospective.Population: Twenty‐six children without fibrosis (median age: 12.9 years, 15 females).Field Strength/Sequence: 3 T; Cartesian gradient‐echo (GRE) BH‐MRE, research application radial GRE FB‐MRE.Assessment: Participants were scanned twice to measure repeatability, without moving the table or changing the participants' position. LS was measured in areas of the liver with numerical confidence ≥90%. Technical quality was examined using measurable liver area (%).Statistical Tests: Agreement of LS between BH‐MRE and FB‐MRE was evaluated using Bland–Altman analysis for SG acceptance rates of 40%, 60%, 80%, and 100%. LS repeatability was assessed using within‐subject coefficient of variation (wCV). The differences in LS and measurable liver area were examined using Kruskal–Wallis and Wilcoxon signed‐rank tests. P < 0.05 was considered significant.Results: FB‐MRE with 60% SG achieved the closest agreement with BH‐MRE (mean difference 0.00 kPa). The LS ranged from 1.70 to 1.83 kPa with no significant differences between BH‐MRE and FB‐MRE with varying SG rates (P = 0.52). All tested methods produced repeatable LS with wCV from 4.4% to 6.5%. The median measurable liver area was smaller for FB‐MRE (32%–45%) than that for BH‐MRE (91%–93%) (P < 0.05).Data Conclusion: FB‐MRE with 60% SG can quantify LS with close agreement and comparable repeatability with respect to BH‐MRE in children.Level of Evidence: 2Technical Efficacy: Stage 1