Shu‐Fu Shih

Shu‐Fu Shih

Auto-generated profile, based on publicly available information

Shu‐Fu Shih

Department of Radiological Sciences David Geffen School of Medicine, University of California Los Angeles Los Angeles California USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

22 April 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
XZXiaodong Zhong
Xiaodong Zhong
MNMarcel D. Nickel
Marcel D. Nickel
SKStephan A. R. Kannengiesser
Stephan A. R. Kannengiesser
BDBrian M. Dale
Brian M. Dale
FHFei Han
Fei Han
VDVibhas Deshpande
Vibhas Deshpande
Purpose: To improve image quality, mitigate quantification biases and variations for free‐breathing liver proton density fat fraction (PDFF) and quantification accelerated by radial k‐space undersampling.Methods: A free‐breathing multi‐echo stack‐of‐radial MRI method was developed with compressed sensing with multidimensional regularization. It was validated in motion phantoms with reference acquisitions without motion and in 11 subjects (6 patients with nonalcoholic fatty liver disease) with reference breath‐hold Cartesian acquisitions. Images, PDFF, and maps were reconstructed using different radial view k‐space sampling factors and reconstruction settings. Results were compared with reference‐standard results using Bland–Altman analysis. Using linear mixed‐effects model fitting (p < 0.05 considered significant), mean and SD were evaluated for biases and variations of PDFF and , respectively, and coefficient of variation on the first echo image was evaluated as a surrogate for image quality.Results: Using the empirically determined optimal sampling factor of 0.25 in the accelerated in vivo protocols, mean differences and limits of agreement for the proposed method were [−0.5; −33.6, 32.7] s−1 for and [−1.0%; −5.8%, 3.8%] for PDFF, close to those of a previous self‐gating method using fully sampled radial views: [−0.1; −27.1, 27.0] s−1 for and [−0.4%; −4.5%, 3.7%] for PDFF. The proposed method had significantly lower coefficient of variation than other methods (p < 0.001). Effective acquisition time of 64 s or 59 s was achieved, compared with 171 s or 153 s for two baseline protocols with different radial views corresponding to sampling factor of 1.0.Conclusion: This proposed method may allow accelerated free‐breathing liver PDFF and mapping with reduced biases and variations.

9 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SSShu‐Fu Shih
Shu‐Fu Shih
BTBilal Tasdelen
Bilal Tasdelen
EYEcrin Yagiz
Ecrin Yagiz
ZZZhaohuan Zhang
Zhaohuan Zhang
XZXiaodong Zhong
Xiaodong Zhong
HWHolden Wu
Holden Wu
Purpose: To improve liver proton density fat fraction (PDFF) and quantification at 0.55 T by systematically validating the acquisition parameter choices and investigating the performance of locally low‐rank denoising methods.Methods: A Monte Carlo simulation was conducted to design a protocol for PDFF and mapping at 0.55 T. Using this proposed protocol, we investigated the performance of robust locally low‐rank (RLLR) and random matrix theory (RMT) denoising. In a reference phantom, we assessed quantification accuracy (concordance correlation coefficient [] vs. reference values) and precision (using SD) across scan repetitions. We performed in vivo liver scans (11 subjects) and used regions of interest to compare means and SDs of PDFF and measurements. Kruskal–Wallis and Wilcoxon signed‐rank tests were performed (p < 0.05 considered significant).Results: In the phantom, RLLR and RMT denoising improved accuracy in PDFF and with >0.992 and improved precision with >67% decrease in SD across 50 scan repetitions versus conventional reconstruction (i.e., no denoising). For in vivo liver scans, the mean PDFF and mean were not significantly different between the three methods (conventional reconstruction; RLLR and RMT denoising). Without denoising, the SDs of PDFF and were 8.80% and 14.17 s−1. RLLR denoising significantly reduced the values to 1.79% and 5.31 s−1 (p < 0.001); RMT denoising significantly reduced the values to 2.00% and 4.81 s−1 (p < 0.001).Conclusion: We validated an acquisition protocol for improved PDFF and quantification at 0.55 T. Both RLLR and RMT denoising improved the accuracy and precision of PDFF and measurements.

10 September 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
QDQing Dai
Qing Dai
SSShu‐Fu Shih
Shu‐Fu Shih
OCOmar Curiel
Omar Curiel
TTTsu‐Chin Tsao
Tsu‐Chin Tsao
DLDavid S. Lu
David S. Lu
HWHolden Wu
Holden Wu
Purpose: To develop and evaluate a volumetric proton resonance frequency shift (PRF)–based thermometry method for monitoring thermal ablation in moving tissues. Methods: A golden‐angle‐ordered 3D stack‐of‐radial MRI sequence was combined with an image‐navigated multi‐baseline (iNAV‐MB) PRF method to reconstruct motion‐compensated 3D temperature maps with high spatiotemporal resolution and volumetric coverage. Two radial MRI reconstruction techniques, k‐space weighted image contrast filter (KWIC) and golden‐angle radial sparse parallel (GRASP) MRI, were implemented and compared within a sliding window reconstruction framework. Ex vivo motion phantom experiments were performed with high‐intensity focused ultrasound ablation to evaluate motion tracking and temperature accuracy using input motion waveforms and temperature probe readings as references. In vivo non‐heating swine experiments were conducted to assess temperature mapping stability in 3D liver regions of interest. Results: The proposed iNAV‐MB thermometry framework achieved volumetric coverage of 24 axial slices (3‐mm thickness), in‐plane resolution of 1.6 × 1.6 to 1.8 × 1.8 mm 2 , and effective temporal resolution of 0.98 s/volume. In ex vivo high‐intensity focused ultrasound experiments, motion tracking achieved correlation coefficients of 0.951 and 0.973, and temporal mean absolute errors were 1.80°C and 1.44°C using KWIC and GRASP, respectively. In vivo experiments demonstrated improvements in voxel‐wise temperature temporal SD from a median of 8.03 to 3.85°C (KWIC) and from a median of 7.23 to 2.37°C (GRASP), compared to single‐baseline PRF. Conclusion: The proposed stack‐of‐radial iNAV‐MB volumetric PRF thermometry framework can reliably track respiratory motion and map ablation‐associated temperature change. This framework has the potential to improve MRI‐guided thermal ablation in moving tissues.

22 July 2024 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
SKSevgi Gokce Kafali
Sevgi Gokce Kafali
BBBradley D. Bolster
Bradley D. Bolster
SSShu‐Fu Shih
Shu‐Fu Shih
TDTimoteo I. Delgado
Timoteo I. Delgado
VDVibhas Deshpande
Vibhas Deshpande
HWHolden Wu
Holden Wu
Background: Conventional liver magnetic resonance elastography (MRE) requires breath‐holding (BH) to avoid motion artifacts, which is challenging for children. While radial free‐breathing (FB)‐MRE is an alternative for quantifying liver stiffness (LS), previous methods had limitations of long scan times, acquiring two slices in 5 minutes, and not resolving motion during reconstruction.Purpose: To reduce FB‐MRE scan time to 4 minutes for four slices and to investigate the impact of self‐gated (SG) motion compensation on FB‐MRE LS quantification in terms of agreement, intrasession repeatability, and technical quality compared to conventional BH‐MRE.Study Type: Prospective.Population: Twenty‐six children without fibrosis (median age: 12.9 years, 15 females).Field Strength/Sequence: 3 T; Cartesian gradient‐echo (GRE) BH‐MRE, research application radial GRE FB‐MRE.Assessment: Participants were scanned twice to measure repeatability, without moving the table or changing the participants' position. LS was measured in areas of the liver with numerical confidence ≥90%. Technical quality was examined using measurable liver area (%).Statistical Tests: Agreement of LS between BH‐MRE and FB‐MRE was evaluated using Bland–Altman analysis for SG acceptance rates of 40%, 60%, 80%, and 100%. LS repeatability was assessed using within‐subject coefficient of variation (wCV). The differences in LS and measurable liver area were examined using Kruskal–Wallis and Wilcoxon signed‐rank tests. P < 0.05 was considered significant.Results: FB‐MRE with 60% SG achieved the closest agreement with BH‐MRE (mean difference 0.00 kPa). The LS ranged from 1.70 to 1.83 kPa with no significant differences between BH‐MRE and FB‐MRE with varying SG rates (P = 0.52). All tested methods produced repeatable LS with wCV from 4.4% to 6.5%. The median measurable liver area was smaller for FB‐MRE (32%–45%) than that for BH‐MRE (91%–93%) (P < 0.05).Data Conclusion: FB‐MRE with 60% SG can quantify LS with close agreement and comparable repeatability with respect to BH‐MRE in children.Level of Evidence: 2Technical Efficacy: Stage 1

1 June 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
QDQing Dai
Qing Dai
JCJason Chiang
Jason Chiang
SSShu‐Fu Shih
Shu‐Fu Shih
WZWenqi Zhou
Wenqi Zhou
DLDavid S. K. Lu
David S. K. Lu
HWHolden Wu
Holden Wu
Purpose: To develop a software‐based active electromagnetic interference (EMI) suppression (AES) framework on whole‐body multi‐channel MRI systems for reliable MRI and MR thermometry during MRI‐guided microwave ablation (MWA). Methods: In addition to primary imaging coils, an unloaded standard body array coil was positioned outside the imaging volume to serve as “auxiliary coils” for detecting and characterizing EMI. At each time frame, principal component analysis compressed the auxiliary coil data to extract the dominant EMI pattern. The EMI coupled into the primary coils was then modeled with channel‐specific impulse response functions and subtracted from the primary coil data on a frame‐by‐frame basis. The framework was evaluated through MWA experiments in gel phantoms and in vivo pig models at 3 T with parallel imaging acceleration. Proton resonance frequency shift (PRF) MR thermometry accuracy was assessed using fiber‐optic probes. The PRF‐derived thermal dose prediction was compared with post‐ablation MRI and tissue gross pathology. Results: AES effectively suppressed EMI‐induced artifacts and substantially improved image quality, yielding signal‐to‐noise ratio enhancement of 40‐fold (gel) and 13‐fold (in vivo) and an EMI suppression rate > 92%. Reliable PRF temperature mapping was enabled, with temporal mean‐absolute‐error of < 1.4°C and < 0.3°C in ablated and non‐heating regions, respectively. Thermal dose estimation matched post‐ablation MRI and gross pathology findings. Conclusion: The proposed AES framework effectively suppressed ablation‐device‐related EMI and enabled reliable MRI and MR thermometry during MWA. This approach can be integrated into existing reconstruction pipelines to facilitate the broader clinical adoption of MRI‐guided MWA and other interventions affected by EMI.