Humberto Zardo

Humberto Zardo

Auto-generated profile, based on publicly available information

Humberto Zardo

University of São Paulo School of Pharmaceutical Sciences São Paulo, SP

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2026 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
HRHarold Alexis Prada Ramirez
Harold Alexis Prada Ramirez
Willy Fernando Cely-VelozaWilly Fernando Cely-Veloza
Willy Fernando Cely-Veloza
Ericsson Coy-BarreraEricsson Coy-Barrera
Ericsson Coy-Barrera
HZHumberto Zardo
Humberto Zardo
JGJeny Guerrero-Bonilla
Jeny Guerrero-Bonilla
RGRaquel Gómez-Pliego
Raquel Gómez-Pliego
Background: Risk-based approaches are increasingly encouraged to optimize microbiological control strategies for non-sterile pharmaceutical materials. Primary packaging materials represent a critical interface, yet routine microbiological testing is often applied uniformly without considering material characteristics or historical performance. Objective: This study aimed to develop and evaluate a risk-based framework to support reducing routine microbiological testing for non-sterile primary packaging materials by integrating water activity (Aw), historical microbiological data, and intrinsic material and process attributes. Methods: Common primary packaging materials, including polyvinyl chloride (PVC), polyvinyl chloride–polyvinylidene chloride (PVC–PVDC), aluminum foil, polyethylene terephthalate (PET), high-density polyethylene (HDPE), low-density polyethylene (LDPE), and polymeric tubes, were evaluated. Water activity was measured and compared against an upper specification limit (Aw ≤ 0.60). Historical microbiological performance was assessed using at least 20 consecutive compliant batches without out-of-specification (OOS) or out-of-trend (OOT) results. A one-sided process capability analysis (Cpk) was performed to characterize Aw variability relative to the specification limit. Results: Historical data supported sustained control across materials, with at least 20 consecutive compliant batches and Aw values consistently ≤0.60. Most materials showed low variability and operated with a substantial margin relative to the Aw limit, whereas HDPE and LDPE exhibited comparatively higher variability. These findings were not associated with evidence of microbiological proliferation within the evaluated dataset. Cpk values quantitatively described observed performance and were interpreted as supportive indicators given the limited dataset. Conclusion: These findings support a risk-based strategy to optimize the frequency of microbiological testing. Historical microbiological performance represents the primary basis for reduced testing, while Aw and material attributes provide complementary evidence. This approach enables optimization of testing under controlled conditions without replacing microbiological control, in alignment with ICH Q9(R1), ICH Q6A, and relevant compendial guidance. Highlights: A risk-based framework that integrates water activity, historical microbiological data, and material attributes is proposed to optimize microbiological testing of non-sterile primary packaging materials. All evaluated materials showed Aw ≤ 0.60, consistent with conditions unfavorable to microbial proliferation, while historical data (≥20 compliant batches) provided the primary evidence of sustained control. Differences in Aw variability were observed, particularly for HDPE and LDPE, highlighting the importance of material-specific characteristics in risk assessment. Overall, the approach supports the reduction—rather than replacement—of microbiological testing under controlled conditions, in alignment with current regulatory expectations.