27 October 2022 in International Transactions on Electrical Energy Systems
An innovative technique has been proposed for determining the position and characteristics of harmonic generating resources in a distribution system. The proposed methodology is primarily based on the wavelet decomposition of power signals on the factor of dimension. Detail power or harmonic power calculation at level 1 reduces the computational burden of the algorithm. The distinguishing harmonics concept can be used to detect a harmonic generating source from the distribution network. The sampling frequency is chosen so that the appropriate harmonic data are captured at level 1 and the pseudo-frequency of the wavelet decomposition at first level is close to the characteristic frequency of the load. The proposed method has been applied in different types of distribution systems to check its validity.
19 November 2026 in Physics in Medicine & Biology
Objective. Diffusion models show strong potential for high-fidelity radiotherapy dose prediction, but their performance depends heavily on the conditioning mechanism. This study introduces a novel conditioning strategy that improves volumetric consistency in slice-wise dose generation while reducing reliance on manually annotated organ-at-risk (OAR) masks. Approach. We propose a diffusion-based dose prediction framework conditioned on features from the full 3D computed tomography (CT) volume and a pre-trained medical image segmentation model. A 3D feature extractor encodes global anatomical information from the entire CT volume to preserve spatial coherence across 2D dose predictions. Rather than relying on manual OAR masks, the model uses anatomical representations from the pre-trained segmentation network, integrated via cross-attention to enable anatomy-aware dose prediction. Main results. The framework, Diff-Seg3D, was evaluated on three lung cancer radiotherapy datasets representing Volumetric Modulated Arc Therapy (VMAT), Fixed Gantry Intensity-Modulated Radiation Therapy (FGIMRT), and 3D Conformal Radiation Therapy (3DCRT) planning techniques. It achieved the numerically lowest mean absolute error (MAE) on all three datasets, with values of 3.16, 4.38, and 4.02 Gy, respectively, and the best dose-volume histogram (DVH) scores (2.64 and 3.82) on VMAT and FGIMRT, while remaining competitive on 3DCRT. Pre-trained 3D anatomical and segmentation encoders improved the baseline diffusion model, with segmentation features improving performance without requiring explicit OAR contours at inference. Significance. This conditioning strategy improves volumetric consistency and anatomical awareness in diffusion-based dose prediction. The framework can serve as a tool for generating treatment-specific, anatomy-conditioned dose priors to guide radiotherapy planning.