Zachary B. Strumpf

Zachary B. Strumpf

Auto-generated profile, based on publicly available information

Zachary B. Strumpf

Division of Pulmonary, Critical Care and Sleep Medicine, University Hospitals Cleveland Medical Center, Cleveland, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in Sleep Health
Verified
Journal Article
Open access
ZSZachary Strumpf
Zachary Strumpf
WGWenbo Gu
Wenbo Gu
CTChih-Wei Tsai
Chih-Wei Tsai
PCPai-Lien Chen
Pai-Lien Chen
EYEric Yeh
Eric Yeh
ACAmbrose A. Chiang
Ambrose A. Chiang
Our objective was to evaluate the performance of Belun Ring with second-generation deep learning algorithms in obstructive sleep apnea (OSA) detection, OSA severity categorization, and sleep stage classification. Belun Ring with second-generation deep learning algorithms REFERENCE TECHNOLOGY: In-lab polysomnography (PSG) SAMPLE: Eighty-four subjects (M: F = 1:1) referred for an overnight sleep study were eligible. Of these, 26% had PSG-AHI<5; 24% had PSG-AHI 5-15; 23% had PSG-AHI 15-30; 27% had PSG-AHI ≥ 30. Rigorous performance evaluation by comparing Belun Ring to concurrent in-lab PSG using the 4% rule. Pearson's correlation coefficient, Student's paired t-test, diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, Cohen's kappa coefficient (kappa), Bland-Altman plots with bias and limits of agreement, receiver operating characteristics curves with area under the curve, and confusion matrix. The accuracy, sensitivity, specificity, and kappa in categorizing AHI ≥ 5 were 0.85, 0.92, 0.64, and 0.58, respectively. The accuracy, sensitivity, specificity, and Kappa in categorizing AHI ≥ 15 were 0.89, 0.91, 0.88, and 0.79, respectively. The accuracy, sensitivity, specificity, and Kappa in categorizing AHI ≥ 30 were 0.91, 0.83, 0.93, and 0.76, respectively. BSP2 also achieved an accuracy of 0.88 in detecting wake, 0.82 in detecting NREM, and 0.90 in detecting REM sleep. Belun Ring with second-generation algorithms detected OSA with good accuracy and demonstrated a moderate-to-substantial agreement in categorizing OSA severity and classifying sleep stages.

25 January 2024 in ATS Scholar
Verified
Journal Article
Open access
ZSZachary Strumpf
Zachary Strumpf
CMCailey Miller
Cailey Miller
KAKaniza Zahra Abbas
Kaniza Zahra Abbas
WBWyatt P. Bensken
Wyatt P. Bensken
MMMaroun Matta
Maroun Matta
Background: Because of the coronavirus disease (COVID-19) pandemic, fellowship interviews for pulmonary disease and critical care medicine (PCCM) switched from an in-person to virtual interview format. Objective: This study aimed to examine the changes that resulted from this switch (appointment year 2021 and beyond) for both the individual applicants and the match process as a whole. Methods: This cross-sectional study used longitudinal data from the Electronic Residency Application Service and the National Resident Matching Program from appointment years 2017 to 2022. Data from the Electronic Residency Application Service included the number of programs applicants applied to, and National Resident Matching Program data included the number of fellowship positions available, number entering the match, match rate, and the number of applicants who matched within the same region/program as their core residency training program. Descriptive and summary statistics and unadjusted linear models were used to identify if trends appeared in post-COVID-19 appointment years (2021 and beyond). Results: The number of PCCM positions increased by 33 (95% confidence interval, 26.2, 39.8) yearly between 2017 and 2022, with almost twice as many applicants (62.6; 95% CI confidence interval, 37.8, 87.4) entering the PCCM fellowship match during that same period. There was a decrease in the percentage of applicants matched each year, a trend unchanged before and after COVID-19, by an average of −2.15%. Comparing before and after COVID-19 appointment years, there was no significant change in same-region or same-program matches. Conclusion: Our analysis shows steadily rising interest in application rates for PCCM fellowships through the onset of the pandemic. However, a lack of proportionate increase in fellowship positions led to a decrease in overall match rates for applicants. To mitigate this, an increase in PCCM fellowship positions should be considered, and surveillance of these trends should continue.

1 May 2023
Verified
Conference Paper
Closed access
ZSZ.B. Strumpf
Z.B. Strumpf
CMC. Miller
C. Miller
KAK.Z. Abbas
K.Z. Abbas
WBW.P. Bensken
W.P. Bensken
MMM. Matta
M. Matta


11 February 2026 in Sleep and Breathing
Verified
Journal Article
Open access
PDF file
ZSZachary B. Strumpf
Zachary B. Strumpf
FKFarhad Kaffashi
Farhad Kaffashi
SPSusheel P. Patil
Susheel P. Patil
KSKingman P. Strohl
Kingman P. Strohl
KLKenneth A. Loparo
Kenneth A. Loparo
FJFrank J. Jacono
Frank J. Jacono
Purpose: Sleep-disordered breathing (SDB), particularly obstructive sleep apnea (OSA), is prevalent in hospitalized patients, yet remains underdiagnosed due to limited screening tools. This pilot study aimed to develop and validate a machine-learning classifier using electrocardiogram (ECG) and pulse oximetry (SpO₂) waveforms to detect SDB, leveraging routinely collected physiological data to enable non-invasive, scalable screening in hospitalized patients. Methods: We utilized data from the Multi-Ethnic Study of Atherosclerosis (MESA) Sleep cohort, which included full overnight polysomnography (PSG). A total of 122 participants were randomly selected, enriched for severe OSA cases. Spectral analysis of R-R intervals and SpO₂ variability was performed, and a support vector machine (SVM) classifier was trained using a subset of subjects ( n = 30). Performance was evaluated in a validation set ( n = 92) using standard classification metrics with 95% CIs calculated. Results: The first-stage classifier (SVM-1) demonstrated high sensitivity (98.7%) and specificity (99.0%) in identifying respiratory events at the window level. The second-stage classifier (SVM-2) correctly classified OSA presence with 100% accuracy in the training set. When applied to the validation set, the combined model achieved a sensitivity of 72.3%, specificity of 73.3%, and F1-score of 73.1%. Performance was impacted by arrhythmias, and lack of direct respiratory effort measures. Conclusion: A machine-learning model using routinely collected ECG and SpO₂ data shows promise for SDB detection but may require additional cardiopulmonary parameters for clinical decision-making in the ICU. Further validation with data collected in real-world ICU settings is warranted.

11 June 2026 in Respiratory Medicine
Verified
Journal Article
Open access
ZSZachary B. Strumpf
Zachary B. Strumpf
SBSanjay Balijepalli
Sanjay Balijepalli
PGPavel Galchenko
Pavel Galchenko
FHFouad Helmy
Fouad Helmy
BYBenjamin P. Young
Benjamin P. Young
SASameer K. Avasarala
Sameer K. Avasarala
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is essential for mediastinal staging in non-small cell lung cancer (NSCLC), yet uniform lymph node (LN) size criteria for sampling remain unvalidated. This single-center retrospective study evaluated consecutive patients who underwent EBUS-TBNA for initial staging of NSCLC with available PET-CT were included. Nonparametric tests compared LN sizes across mediastinal stations 4R, 4L, and 7. Among 205 patients (median age 69 years), 1306 LNs were analyzed, including 770 nodes ≥5 mm and 449 mediastinal LNs. Significant size variation was observed across stations in benign nodes (p < 0.001), particularly between 4R or 4L versus 7, while malignant nodes did not differ significantly (p = 0.065). These findings suggest that uniform LN size cutoffs for EBUS-TBNA may not be optimal across mediastinal stations. Prospective, multicenter validation is warranted to refine evidence-based criteria for EBUS-guided mediastinal staging.