Chih-Wei Tsai

Dr. Chih-Wei Tsai

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in Sleep Health
Verified
Journal Article
Open access
ZSZachary Strumpf
Zachary Strumpf
WGWenbo Gu
Wenbo Gu
CTChih-Wei Tsai
Chih-Wei Tsai
PCPai-Lien Chen
Pai-Lien Chen
EYEric Yeh
Eric Yeh
ACAmbrose A. Chiang
Ambrose A. Chiang
Our objective was to evaluate the performance of Belun Ring with second-generation deep learning algorithms in obstructive sleep apnea (OSA) detection, OSA severity categorization, and sleep stage classification. Belun Ring with second-generation deep learning algorithms REFERENCE TECHNOLOGY: In-lab polysomnography (PSG) SAMPLE: Eighty-four subjects (M: F = 1:1) referred for an overnight sleep study were eligible. Of these, 26% had PSG-AHI<5; 24% had PSG-AHI 5-15; 23% had PSG-AHI 15-30; 27% had PSG-AHI ≥ 30. Rigorous performance evaluation by comparing Belun Ring to concurrent in-lab PSG using the 4% rule. Pearson's correlation coefficient, Student's paired t-test, diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, Cohen's kappa coefficient (kappa), Bland-Altman plots with bias and limits of agreement, receiver operating characteristics curves with area under the curve, and confusion matrix. The accuracy, sensitivity, specificity, and kappa in categorizing AHI ≥ 5 were 0.85, 0.92, 0.64, and 0.58, respectively. The accuracy, sensitivity, specificity, and Kappa in categorizing AHI ≥ 15 were 0.89, 0.91, 0.88, and 0.79, respectively. The accuracy, sensitivity, specificity, and Kappa in categorizing AHI ≥ 30 were 0.91, 0.83, 0.93, and 0.76, respectively. BSP2 also achieved an accuracy of 0.88 in detecting wake, 0.82 in detecting NREM, and 0.90 in detecting REM sleep. Belun Ring with second-generation algorithms detected OSA with good accuracy and demonstrated a moderate-to-substantial agreement in categorizing OSA severity and classifying sleep stages.

11 October 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EYEric Yeh
Eric Yeh
EWEileen Wong
Eileen Wong
CTChih-Wei Tsai
Chih-Wei Tsai
WGWenbo Gu
Wenbo Gu
PCPai-Lien Chen
Pai-Lien Chen
ACAmbrose A. Chiang
Ambrose A. Chiang
Many wearables allow physiological data acquisition in sleep and enable clinicians to assess sleep outside of sleep labs. Belun Sleep Platform (BSP) is a novel neural network-based home sleep apnea testing system utilizing a wearable ring device to detect obstructive sleep apnea (OSA). The objective of the study is to assess the performance of BSP for the evaluation of OSA. Subjects who take heart rate-affecting medications and those with non-arrhythmic comorbidities were included in this cohort. Polysomnography (PSG) studies were performed simultaneously with the Belun Ring in individuals who were referred to the sleep lab for an overnight sleep study. The sleep studies were manually scored using the American Academy of Sleep Medicine Scoring Manual (version 2.4) with 4% desaturation hypopnea criteria. A total of 78 subjects were recruited. Of these, 45% had AHI < 5; 18% had AHI 5–15; 19% had AHI 15–30; 18% had AHI ≥ 30. The Belun apnea-hypopnea index (bAHI) correlated well with the PSG-AHI (r = 0.888, P < 0.001). The Belun total sleep time (bTST) and PSG-TST had a high correlation coefficient (r = 0.967, P < 0.001). The accuracy, sensitivity, specificity in categorizing AHI ≥ 15 were 0.808 [95% CI, 0.703–0.888], 0.931 [95% CI, 0.772–0.992], and 0.735 [95% CI, 0.589–0.850], respectively. The use of beta-blocker/calcium-receptor antagonist and the presence of comorbidities did not negatively affect the sensitivity and specificity of BSP in predicting OSA. A diagnostic algorithm combining STOP-Bang cutoff of 5 and bAHI cutoff of 15 events/h demonstrated an accuracy, sensitivity, specificity of 0.938 [95% CI, 0.828–0.987], 0.944 [95% CI, 0.727–0.999], and 0.933 [95% CI, 0.779–0.992], respectively, for the diagnosis of moderate to severe OSA. BSP is a promising testing tool for OSA assessment and can potentially be incorporated into clinical practices for the identification of OSA. Trial registration: ClinicalTrial.org NCT03997916 https://clinicaltrials.gov/ct2/show/NCT03997916?term=belun+ring&draw=2&rank=1

1 May 2019
Verified
Conference Paper
Closed access
CCChongyan Chen
Chongyan Chen
CLChunhung Li
Chunhung Li
CTChih-Wei Tsai
Chih-Wei Tsai
XDXinghua Deng
Xinghua Deng
Heart Rate Variability (HRV) is a significant indicator of physical fitness and mental stresses. Electrocardiography (ECG) is the most common means to detect HRV. However, the nature of the ECG detection limits its convenience and usage time. While wrist-based Photoplethysmography (PPG) provides the possibility of convenient 24/7 HRV monitoring, its accuracy has not been systematically analyzed. We experimented with six healthy subjects and measured PPG from their wrist and ECG from their chest. The result shows that ten HRV parameters have significant differences between stress and non-stress states. Furthermore, the 10-fold accuracy of stress state detection within subjects is 98% and the Leave-One-Participant-Out F1score reaches 80%. The results demonstrate that wrist-based PPG can provide HRV measurements that enable the recognition of mental stress as accurately as ECG, even for a short three-minute temporal window.

1 October 2017 in Applied Geography
Verified
Journal Article
Open access
CTChih-Wei Tsai
Chih-Wei Tsai
TYThomas Young
Thomas Young
PWPhilip H. Warren
Philip H. Warren
LMLorraine Maltby
Lorraine Maltby

1 January 2016 in Urban Forestry & Urban Greening
Verified
Journal Article
Closed access
CTChih-Wei Tsai
Chih-Wei Tsai
TYThomas Young
Thomas Young
PWPhilip H. Warren
Philip H. Warren
LMLorraine Maltby
Lorraine Maltby

9 May 2018 in Arthropod-Plant Interactions
Verified
Journal Article
Closed access
PDF file
LLLi-Chuan Lai
Li-Chuan Lai
MCMing-Chung Chiu
Ming-Chung Chiu
CTChih-Wei Tsai
Chih-Wei Tsai
WWWen-Jer Wu
Wen-Jer Wu