1 April 2019 in Radiology
Verified
Journal Article
Closed access
PSPer Skaane
Per Skaane
ABAndriy I. Bandos
Andriy I. Bandos
LNLoren T. Niklason
Loren T. Niklason
SSSofie Sebuødegård
Sofie Sebuødegård
BØBjørn H. Østerås
Bjørn H. Østerås
SHSolveig Hofvind
Solveig Hofvind
Background Digital breast tomosynthesis (DBT) is replacing digital mammography (DM) in the clinical workflow. Currently, there are limited prospective studies comparing the diagnostic accuracy of both examinations and the role of synthetic mammography (SM) and computer-aided detection (CAD). Purpose To compare the accuracy of DM versus DM + DBT in population-based breast cancer screening. Materials and Methods This prospective study, performed from November 2010 to December 2012, included 24 301 women (mean age, 59.1 years ± 5.7 [standard deviation]) with 281 cancers, of which 51 were interval cancers. Each examination was independently interpreted with four reading modes: DM, DM + CAD, DM + DBT, and SM + DBT. Sensitivity and specificity were compared for DM versus DM + DBT, DM versus DM + CAD, DM + DBT versus SM + DBT, and DM versus DM + DBT at double reading. Reader-adjusted performance characteristics of reading modes were evaluated on the basis of pre-arbitration (initial interpretation) scores. Statistical analysis was based on cluster bootstrap analysis using 10 000 random resamples. Results Sensitivity was 54.1% (152 of 281) for DM and 70.5% (198 of 281) for DM + DBT. Reader-adjusted difference was 12.6% (95% confidence interval [CI]: 5.2%, 19.7%; P = .001). Specificity was 94.2% (false-positive fraction [FPF], 5.8%; 1388 of 24 020) for DM and 95.0% (FPF, 5.0%; 1209/24 020) for DM + DBT, with a reader-adjusted difference in FPF of -1.2% (95% CI: -1.7%, -0.7%; P < .001). Sensitivity was 69.0% (194 of 281) for SM + DBT and 70.5% (198 of 281) for DM + DBT, with a reader-adjusted difference of 1.0% (95% CI: -6.2%, 8.5%; P = .77). Specificity was 95.4% (FPF, 4.6%; 1111 of 24 020) for SM + DBT and 95.0% (FPF, 5.0%;1209 of 24 020) for DM + DBT, with reader-adjusted 95% CIs for FPF of 4.7%, 5.4% and 5.0%, 5.7%, respectively, and a difference of -0.3% (95% CI: -0.8%, 0.2%; P = .23). Differences in sensitivity and specificity with the addition of CAD were small and not significant (P > .2). Conclusion Addition of digital breast tomosynthesis to digital mammography resulted in significant gains in sensitivity and specificity. Synthetic mammography in combination with digital breast tomosynthesis had similar sensitivity and specificity to digital mammography in combination with digital breast tomosynthesis. © RSNA, 2019 See also the editorial by Lång in this issue.

10 February 2018 in Breast Cancer Research and Treatment
Verified
Journal Article
Closed access
PDF file
PSPer Skaane
Per Skaane
SSSofie Sebuødegård
Sofie Sebuødegård
ABAndriy I. Bandos
Andriy I. Bandos
DGDavid Gur
David Gur
BØBjørn Helge Østerås
Bjørn Helge Østerås
SHSolveig Hofvind
Solveig Hofvind

1 October 2019 in Radiology
Verified
Journal Article
Closed access
BØBjørn Helge Østerås
Bjørn Helge Østerås
AMAnne Catrine T. Martinsen
Anne Catrine T. Martinsen
RGRandi Gullien
Randi Gullien
PSPer Skaane
Per Skaane
BackgroundPrevious studies comparing digital breast tomosynthesis (DBT) to digital mammography (DM) have shown conflicting results regarding breast density and diagnostic performance.PurposeTo compare true-positive and false-positive interpretations in DM versus DBT according to volumetric density, age, and mammographic findings.Materials and MethodsFrom November 2010 to December 2012, 24 301 women aged 50-69 years (mean age, 59.1 years ± 5.7) were prospectively included in the Oslo Tomosynthesis Screening Trial. Participants received same-compression DM and DBT with independent double reading for both DM and DM plus DBT reading modes. Eight experienced radiologists rated the images by using a five-point scale for probability of malignancy. Participants were followed up for 2 years to assess for interval cancers. Breast density was assessed by using automatic volumetric software (scale, 1-4). Differences in true-positive rates, false-positive rates, and mammographic findings were assessed by using confidence intervals (Newcombe paired method) and P values (McNemar and χ2 tests).ResultsThe true-positive rate of DBT was higher than that of DM for density groups (range, 12%-24%; P < .001 for density scores of 2 and 3, and P > .05 for density scores of 1 and 4) and age groups (range, 15%-35%; P < .05 for all age groups), mainly due to the higher number of spiculated masses and architectural distortions found at DBT (P < .001 for density scores of 2 and 3; P < .05 for women aged 55-69 years). The false-positive rate was lower for DBT than for DM in all age groups (range, -0.6% to -1.2%; P < .01) and density groups (range, -0.7 to -1.0%; P < .005) owing to fewer asymmetric densities (P ≤ .001), except for extremely dense breasts (0.1%, P = .82).ConclusionDigital breast tomosynthesis enabled the detection of more cancers in all density and age groups compared with digital mammography, especially cancers classified as spiculated masses and architectural distortions. The improvement in cancer detection rate showed a positive correlation with age. With use of digital breast tomosynthesis, false-positive findings were lower due to fewer asymmetric densities, except in extremely dense breasts.© RSNA, 2019Online supplemental material is available for this article.See also the editorial by Fuchsjäger and Adelsmayr in this issue.

25 January 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
BØBjørn Helge Østerås
Bjørn Helge Østerås
PSPer Skaane
Per Skaane
RGRandi Gullien
Randi Gullien
AMAnne Catrine Trægde Martinsen
Anne Catrine Trægde Martinsen
The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra ™ ). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra ™ . AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c -factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c -factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

11 July 2016 in Acta Radiologica
Verified
Journal Article
Closed access
BØBjørn Helge Østerås
Bjørn Helge Østerås
AMAnne Catrine T Martinsen
Anne Catrine T Martinsen
Siri Helene Bertelsen BrandalSiri Helene Bertelsen Brandal
Siri Helene Bertelsen Brandal
KCKhalida Nasreen Chaudhry
Khalida Nasreen Chaudhry
EEEllen Eben
Ellen Eben
PSPer Skaane
Per Skaane
Background: Automatically calculated breast density is a promising alternative to subjective BI-RADS density assessment. However, such software needs a cutoff value for density classification. Purpose: To determine the volumetric density threshold which classifies fatty and dense breasts with highest accuracy compared to average BI-RADS density assessment, and to analyze radiologists’ inter-observer variation. Material and Methods: A total of 537 full field digital mammography examinations were randomly selected from a population based screening program. Five radiologists assessed density using the BI-RADS density scale, where BI-RADS I–II were classified as fatty and III–IV as dense. A commercially available software (Quantra) calculated volumetric breast density. We calculated the cutoff (threshold) values in volumetric density that yielded highest accuracy compared to median and individual radiologists’ classification. Inter-observer variation was analyzed using the kappa statistic. Results: The threshold that best matched the median radiologists’ classification was 10%, which resulted in 87% accuracy. Thresholds that best matched individual radiologist’s classification had a range of 8–15%. A total of 191 (35.6 %) cases were scored both dense and fatty by at least one radiologist. Fourteen (2.6 %) cases were unanimously scored by the radiologists, yet differently using automatic assessment. The agreement (kappa) between reader’s median classification and individual radiologists was 0.624 to 0.902, and agreement between median classification and Quantra was 0.731. Conclusion: The optimal volumetric threshold of 10% using automatic assessment would classify breast parenchyma as fatty or dense with substantial accuracy and consistency compared to radiologists’ BI-RADS categorization, which suffers from high inter-observer variation.

1 March 2013 in Acta Radiologica
Verified
Journal Article
Closed access
SKSamuel Kuttner
Samuel Kuttner
RBRobert Bujila
Robert Bujila
MKMika Kortesniemi
Mika Kortesniemi
HAHenrik Andersson
Henrik Andersson
LKLove Kull
Love Kull
ITIvanka Sojat Tarp
Ivanka Sojat Tarp
Background Quality assurance (QA) of computed tomography (CT) systems is one of the routine tasks for medical physicists in the Nordic countries. However, standardized QA protocols do not yet exist and the QA methods, as well as the applied tolerance levels, vary in scope and extent at different hospitals. Purpose To propose a standardized protocol for acceptance and constancy testing of CT scanners in the Nordic Region. Material and Methods Following a Nordic Association for Clinical Physics (NACP) initiative, a group of medical physicists, with representatives from four Nordic countries, was formed. Based on international literature and practical experience within the group, a comprehensive standardized test protocol was developed. Results The proposed protocol includes tests related to the mechanical functionality, X-ray tube, detector, and image quality for CT scanners. For each test, recommendations regarding the purpose, equipment needed, an outline of the test method, the measured parameter, tolerance levels, and the testing frequency are stated. In addition, a number of optional tests are briefly discussed that may provide further information about the CT system. Conclusion Based on international references and medical physicists’ practical experiences, a comprehensive QA protocol for CT systems is proposed, including both acceptance and constancy tests. The protocol may serve as a reference for medical physicists in the Nordic countries.