15 February 2008 in IEEE Sensors Journal
Haptic perception plays a very important role in surgery. It enables the surgeon to feel organic tissue hardness, measure tissue properties, evaluate anatomical structures, and allows him/her to commit appropriate force control actions for safe tissue manipulation. However, in minimally invasive surgery, the surgeon's ability of perceiving valuable haptic information through surgical instruments is severely impaired. Performing the surgery without such sensory information could lead to increase of tissue trauma and vital organic tissue damage. In order to restore the surgeon's perceptual capability, methods of force and tactile sensing have been applied with attempts to develop instruments that can be used to detect tissue contact forces and generate haptic feedback to the surgeon. This paper reviews the state-of-the-art in force and tactile sensing technologies applied in minimally invasive surgery. Several sensing strategies including displacement-based, current-based, pressure-based, resistive-based, capacitive-based, piezoelectric-based, vibration-based, and optical-based sensing are discussed.
10 September 2005 in Journal of Manufacturing Science and Engineering
This paper provides a detailed review of the state of the art in product cost estimation covering various techniques and methodologies developed over the years. The overall work is categorized into qualitative and quantitative techniques. The qualitative techniques are further subdivided into intuitive and analogical techniques, and the quantitative ones into parametric and analytical techniques. Each of the techniques is then described and discussed, in detail, with further subdivisions. The paper also signifies the importance of cost estimation in the early phases of the design cycle and, as such, briefly discusses the current trends and future directions in the area. Research work carried out in the field with reference to specific applications is also reviewed. The paper provides a comprehensive literature review in the field and should be useful to researchers and practitioners interested in this field.
17 March 2011 in IEEE/ASME Transactions on Mechatronics
Minimally invasive surgery (MIS) is a surgical technique that offers distinct advantages in reducing pain and patients' recovery time. However, the drawback due to the lack of force and tactile feedback presents a great deal of limitations in MIS procedures. Tissue palpation, which is easily conducted during traditional open surgery to examine tissue properties and abnormalities, is not possible when performing surgery in a minimally invasive manner. This paper proposes a specially designed miniature 3-axis distal force sensor that can be used to perform tissue palpation, measuring tissue interaction forces at the tip of a surgical instrument. Relying on an optical sensing scheme, the sensor can measure forces within measurement ranges of ±3 N in axial direction and ±1.5 N in radial direction. The resolution is 0.02 N. It is compatible with laparoscopic operations and can be used to localize tissue lesions or relatively hard nodules buried under an organ's surface, which are not detectable by visual means.
12 September 2017 in Advanced Engineering Materials
ASAlejandro Diaz De Cerio Sanchez
Alejandro Diaz De Cerio Sanchez
7 August 2002 in IEEE Sensors Journal
This paper reviews the state of the art in sensors and automated inspection devices for enhanced sewer inspection. Efficiency, safety, environmental, and legislative concerns have made inspection and assessment of communal sewers a central issue to water and sewerage companies. Nowadays, the standard sewer inspection system is based on a wheeled platform on which a closed circuit television (CCTV) camera is mounted. One of the disadvantages of camera inspection systems is that they can only detect a small proportion of all possible damage in a sewer. The inspection outcome of such systems relies not only on the quality of the acquired images, but also on the off-line. recognition and classification conducted by human operators. In consequence, CCTV-based platforms are frequently not effective. Infrared, microwave, optical, and ultrasonic-based sensors have been proposed to complement the existing CCTV-based approach and to improve inspection results. New inspection devices employing multiple sensors and being capable of carrying out remote sewer inspection tasks are under research.